AE-Air APHH Horizontal Fan Coil with Plenum Chilled Water Owner’s Manual

June 9, 2024
AE-Air

AE-Air APHH Horizontal Fan Coil with Plenum Chilled Water

AE-Air-APHH-Horizontal-Fan-Coil-with-Plenum-Chilled-Water-
fig-1

APHH Features

  • Factory installed return air plenum
  • Copper tube coils
  • Manual air vents
  • 240/24V relay/transformer
  • Factory installed electric heat
  • ETL Listed 277V option available
  • 2-Speed motor
  • Sloped and insulated drain pan
  • Throwaway filter
  • 220V, 50Hz models available (non ETL)

STANDARD FEATURES

  • Basic Unit
    All fan coils are manufactured with heavy gauge galvanized steel to resist corrosion. All models are approved for installation with “0” clearance to combustible material.

  • Insulation
    Plenums and cabinets are insulated with Tuf-Skin dual density fiber glass blanket insulation with an anti-microbial agent.

  • Ceiling Panels
    Hinged access/return panels are manufactured with heavy gauge galvanized steel with captive mounting screws and an attractive white baked powder finish.

  • Condensate Pans

    • Positive sloped drain pans are galvanized steel, coated on the inside surface with insulation.
    • Pan includes both primary and secondary drain connections.
  • Return Air Plenums
    Return air plenums are manufactured from galvanized steel insulated with dual density fiber glass blanket insulation and a 1” TA fiber glass filter.

  • Coils
    Constructed with seamless copper tubes and headers. The tubes are mechanically expanded into corrugated aluminum fin material for a permanent primary to secondary surface bond. Coils are tested under water at 450 PSI for operation at 300 PSI. Coils include manual air vents.

  • Fan Wheels-Housing
    The fan wheels are double width, double inlet (DWDI) forward curved, centrifugal type. Wheels are statically and dynamically balanced for smooth, quite operation. The housing is constructed from heavy gauge galvanized steel with die-formed inlet cones.

  • Motors
    Standard motors are PSC, permanently lubricated type with internal thermal overload protection.

  • Options
    Factory mounted options include ECM motors stainless steel drain pans, foil faced cabinet insulation, Multi-24 3-speed 24V control, valve packages, thermostats, aqua stats, service switches. 120V, 208V/230V, 277V, 60hz

MODEL NOMENCLATURE

AE-Air-APHH-Horizontal-Fan-Coil-with-Plenum-Chilled-Water-
fig-2
AE-Air-APHH-Horizontal-Fan-Coil-with-Plenum-Chilled-Water-
fig-3

PLENUM DATA

MODEL| A| B| C| D (FILTER)
3APHHS| 20| 18| 15| 10 X 20 X 1
4APHHS

6APHHS

6APHH

8APHH

|

34

|

32

|

30

|

10 X 34 X1

10APHH| 40| 38| 36| 10 X 40 X 1
12APHH| 46| 44| 42| 10 X 46 X 1

NOTE:

  1. Return plenums are insulated
  2. All plenums include throw away filter

BLOWER PERFORMANCE

APHH SERIES 230V

APHH SERIES| CFM vs EXTERNAL STATIC PRESSURE (3 ROW)


MODEL

| ****

H.P.

| FAN SPEED| EXTERNAL STATIC PRESSURE (inches of water)
0.0| 0.05| 0.10| 0.15| 0.20| 0.25| 0.30| 0.35


3APHHS-3

| ****

1/30

| COOL| 270| 255| 215| 180| 150| 105| —| —
HEAT| 250| 215| 185| 160| 130| 80| —| —


4APHHS-3

| ****

1/15

| COOL| 430| 395| 350| 295| 239| —| —| —
HEAT| 340| 320| 295| 255| 202| —| —| —


6APHHS-3

| ****

1/12

| COOL| 570| 490| 415| 335| 245| 140| —| —
HEAT| 290| 285| 270| 230| 175| 60| —| —


6APHH-3

| ****

1/8

| COOL| 820| 765| 710| 660| 615| 570| 530| 485
HEAT| 720| 673| 625| 575| 535| 495| 460| 415


8APHH-3

| ****

1/4

| COOL| —| —| 860| 830| 800| 770| 740| 710
HEAT| —| —| 555| 540| 525| 505| 490| 470


10APHH-3

| ****

1/4

| COOL| —| —| 1050| 1010| 965| 920| 875| 825
HEAT| —| —| 760| 735| 710| 675| 640| 600


12APHH-3

| ****

1/3

| COOL| —| —| 1230| 1205| 1165| 1115| 1065| 1005
HEAT| —| —| 910| 870| 835| 805| 765| 720
APHH SERIES

APHH SERIES| CFM vs EXTERNAL STATIC PRESSURE (4 ROW)


MODEL

| ****

H.P.

| “FAN SPEED”| EXTERNAL STATIC PRESSURE (inches of water)
0.0| 0.05| 0.10| 0.15| 0.20| 0.25| 0.30| 0.35


3APHHS-4

| ****

1/30

| COOL| 225| 195| 165| 130| 90| 55| —| —
HEAT| 210| 175| 145| 115| 80| 45| —| —


4APHHS-4

| ****

1/15

| COOL| 420| 375| 315| 243| 170| 50| —| —
HEAT| 330| 305| 265| 208| 150| 50| —| —


6APHHS-4

| ****

1/12

| COOL| 500| 450| 395| 320| 245| 245| —| —
HEAT| 325| 320| 300| 245| 190| 100| —| —


6APHH-4

| ****

1/8

| COOL| —| —| 680| 645| 610| 570| 530| 490
HEAT| —| —| 645| 565| 485| 430| 395| 360


8APHH-4

| ****

1/4

| COOL| —| —| 740| 690| 645| 605| 560| 515
HEAT| —| —| 650| 610| 570| 530| 490| 445


10APHH-4

| ****

1/4

| COOL| —| —| 990| 950| 915| 875| 840| 800
HEAT| —| —| 750| 725| 700| 675| 650| 620


12APHH-4

| ****

1/3

| COOL| —| —| 1200| 1150| 1110| 1065| 1020| 975
HEAT| —| —| 900| 870| 840| 800| 760| 710

GUIDE SPECIFICATIONS

General
  1. SECTION INCLUDES

  2. Fan Coil Units

  3. REFERENCES

    • AMCA 99 – Standards Handbook
    • AMCA 210 — Laboratory Methods for Testing Fans for Rating Purposes
    • AMCA 300 – Test Code for Sound Rating Air Moving Devices
    • ARI 440 – Room Fan-Coil Unit
    • ASTMB117 – Standard Practice for Operating Salt Spray Apparatus
    • NEMA MGI – Motors and Generators
    • NFPA 70 – National Electric Code
    • SMACNA – HVAC Duct Construction Standards – Metal and Flexible
    • UL 723 – Test for Surface Burning Characteristics of Building Materials
    • UL 900 – Test Performance of Air Filter Units
    • UL 1995 – Standard for Heating and Cooling Equipment
    • UL 94 – Test for Flammability of Plastic Materials for Parts in Devices and Appliances
  4. SUBMITTALS

    • Shop drawings: Indicate assembly, unit dimensions, weight loading, required clearances, construction details, field connection details, and electrical characteristics and connection requirements. A computer generated capacity selection shall be submitted for each cooling coil with design points and final operating point clearly noted.
    • Product Data:
    1. Provide literature that indicates dimensions, weights, capacities, ratings, fan performance, finishes of materials, and electrical characteristics and connection requirements.
    2. Provide data of filter media, filter performance data.
    3. Manufacturer’s installation instructions.
  5. OPERATION AND MAINTENANCE DATA
    Maintenance Data: Include instructions for lubrication, filter replacement and motor and drive replacement.

  6. QUALIFICATIONS
    Maintenance Data: Include instructions for lubrication, filter replacement and motor and drive replacement.

  7. DELIVERY, STORAGE, AND HANDLING

    •  Accept products on site on factory-installed shipping skids. Inspect for damage.
    • Store in clean dry place and protect from weather and construction traffic. Handle carefully to avoid damage to components, enclosures, and finish.
  8. ENVIRONMENTAL REQUIREMENTS
    Do not operate units for any purpose, temporary or permanent, until ductwork is clean, filters are in place, and fan has been test run under observation.

Products
  1. MANUFACTURERS

    • The following manufacturers are approved for use. No substitutions will be permitted.
    1. First Company, Dallas TX
  2. CASING

    • Unit shall have corrosion resistant casing consisting of galvanized steel panels. Unit panels shall be fully insulated with 1.5lb fiberglass insulation with anti-microbial agent. Removable panels shall provide full access to unit components..
    • Drain pans shall be heavy gauge galvanized steel with an insulating coating. Optional stainless steel drain pan shall include an insulating coating. Drain pans shall be removable for cleaning or replacement without removing coils or disturbing coil connections.
  3. SUPPLY FAN

    • Provide DWDI forward-curved supply fans. Fan assemblies shall be statically and dynamically balanced by manufacturer. The housings are constructed from heavy gauge galvanized steel with die-formed inlet cones.
    • Fan and motor mounting platform shall be a minimum of 12 gauge LFQ galvanized steel.
  4. MOTORS
    Direct drive motors to be PSC or ECM type, permanently lubricated type with internal thermal overload protection and mounted with rubber isolation bushings.

  5. ELECTRICAL
    A. Provide units with 115, 208-230, or 277V, 3-speed with 24v control transformer, and 15 amp service switch or optional ECM motor with 120/24V control transformer, 15 amp service switch, 4 speed taps. Controls to be factory mounted and tested.

  6. COOLING AND HEATING COIL SECTIONS

    • Provide access to coils for service and cleaning..
    • Water Coils: fins shall have full drawn collars to provide a continuous surface cover over the entire tube for maximum heat transfer. Tubes shall be mechanically expanded into the fins to provide a continuous primary-tosecondary compression bond over the entire finned length for maximum heat transfer rates. Bare copper tube shall not be visible between fins. Coil tubes shall be seamless copper, expanded into fins, and brazed at joints. Coil connections shall be copper with sweat connection size to be determined by manufacturer based upon the most efficient coil circuiting. Manual air vent connections shall be provided at the highest point to assure proper venting. Coils shall be tested with 350 pounds air pressure and suitable for 300 psig working pressure. Coil casings shall be a formed channel frame of galvanized steel.
  7. FILTERS

    • Filter to be disposable type and media shall be UL 900 listed, Class I or Class II.
    • MERV 8 can be used as an option, will increase static by 0.25

Execution

  • INSTALLATION
    Install in accordance with manufacturer’s instructions.

ACCESS PANELS /FILTER

AE-Air-APHH-Horizontal-Fan-Coil-with-Plenum-Chilled-Water-
fig-4

*STANDARD PANEL OPTIONS FOR HBC SERIES*| IAQ MERV 8 PANEL OPTIONS FOR HBC SERIES
---|---
PART #| UNIT SIZE| PANEL TYPE| FRAME DIMENSIONS| FILTER SIZE| PART #| UNIT SIZE| PANEL TYPE| FRAME DIMENSIONS| FILTER SIZE
965| 3,4,5,6| LOUVERED| 27-1/2 X 43| 20X20X1 (1)| **

965-M8

| 3,4,5,6| LOUVERED| 27-1/2 X 43| 20X30X1 (1)
965-1| SOLID
966| 8| LOUVERED| 27-1/2 X 49| 20X20X1 (1)| ****

966-M8

| 8| LOUVERED| 27-1/2 X 49| 20X20X1 (2)
966-1| SOLID
967| 10| LOUVERED| 27-1/2 X 55-1/2| 20X20X1 (1)| ****

967-M8

| 10| LOUVERED| 27-1/2 X 55-1/2| 20X20X1 (2)
967-1| SOLID
967-4| 12/13| LOUVERED| 27-5/8 X 70-1/8| 10X65X1 (1)| ****

967-8M8

| 12/13| LOUVERED| 27-5/8 X 70-1/8| 20X30X1 (2)
967-5| SOLID

NOTE: * Filters not included

IAQ PANEL PERFORMANCE DATA (4) (Clean Filter)

 | CFM
 | 500| 600| 700| 800| 900| 1000| 1100| 1200| 1300| 1500
965-M8 with AF20301HV (20×030, Merv 8) Filters (2)| 0.04| 0.06| 0.06| 0.08| 0.09| 0.10| – – –| – – –| – – –| – – –
966-M8 with AF20201HV (20×020, Merv 8) Filters (2)| 0.04| 0.06| 0.06| 0.08| 0.09| 0.10| – – –| – – –| – – –| – – –
967-M8 with AF20201HV (20×020, Merv 8) Filters (2)| – – –| 0.05| 0.05| 0.07| 0.08| 0.10| – – –| – – –| – – –| – – –
967-6-M8 with AF20251HV (20×025, Merv 8) Filters (2)| – – –| – – –| – – –| 0.05| 0.06| 0.07| 0.08| 0.09| – – –| – – –
967-8-M8 with AF20301HV (20×30, Merv 8) Filters (2)| – – –| – – –| – – –| – – –| – – –| 0.06| 0.06| 0.08| 0.08| 0.10

NOTES:

  1. The above is the actual laboratory test data or these panels.
  2. Glassfloss® Industries HV series Merv 8 filters were used to generate above data (filters must be field supplied)
  3. Alternate Merv 8 filters would be acceptable provided they have equal or less resistance.
  4. Refer to fan coil specification sheets for fan coil blower data.

ACCESSORIES

AE-Air-APHH-Horizontal-Fan-Coil-with-Plenum-Chilled-Water-
fig-5 AE-Air-APHH-Horizontal-Fan-
Coil-with-Plenum-Chilled-Water-fig-6 AE-Air-APHH-Horizontal-Fan-Coil-with-Plenum-Chilled-Water-
fig-7

PIPING PACKAGE OPTIONS

  • TWO POSITION OR MODULATING
  • Manual air vents are standard and are factory mounted on all chilled water and hot water coils.
  • All pre-piped on/off or modulating valve packages are factory assembled with sweat connections.

AE-Air-APHH-Horizontal-Fan-Coil-with-Plenum-Chilled-Water-
fig-8
AE-Air-APHH-Horizontal-Fan-Coil-with-Plenum-Chilled-Water-
fig-9

  • Add Options:
    Y-Strainers, Pete’s Plugs, Cleanout Blow-down, SS hose kits, Aquastats Additional options and configurations may be available.

  • Contact factory for availability.

  • Valve packages are available as kits or factory mounted on certain products. Contact factory for availability.