SCS sentinel MBA0054 Swivel Wing Gate Drive Instruction Manual

June 9, 2024
SCS sentinel

SCS sentinel-logo

SCS sentinel MBA0054 Swivel Wing Gate Drive

SCS-sentinel-MBA0054-Swivel-Wing-Gate-Drive-Product
image

SAFETY INSTRUCTIONS

WARNING: Important safety instructions. It is essential to follow these instructions for reasons of personal L ! 1 safety. Keep these instructions in a safe place result in serious injury.
This product is only designed for the automation of a sliding gate for «residential» use.
The power supply installation must comply with current standards in the country where the product is installed (NFC 15-100 for France) and be carried out by qualified staff.
The mains supply must be protected against overload by a suitable trip switch and an earth leakage circuit breaker.

CAUTION: The motorised system must be disconnected from its power source during cleaning, maintenance -I and parts replacement.
Installation requires qualified staff with mechanical and electrical skills. Make sure that the temperature range indicated on the motorized device is suitable for the installation’s location. Only original parts should be used to replace or repair the motorized system. – This appliance may be used by children at least 8 years old and by people with reduced physical, sensory or mental capabilities or without experience or knowledge, if they are properly supervised or instructed in the safe use of the appliance, and if the risks involved have been understood. Children should not play with the appliance. The user’s cleaning and maintenance must not be carried out by unsupervised children.

  • Do not allow children to play with the unit or its controls, including remote controls.
  • Activation of the manual disconnection device may cause uncontrolled movement of the driven part due to mechanical failure or loss of balance.
  • Before installing the motorised device, check that the driven part is in good mechanical condition, properly balanced and opens and closes correctly.
  • The motorized device cannot be used with a driven part incorporating a side gate.
  • Ensure that crushing caused by the opening movement of the driven part is avoided between the driven part and the surrounding fixed parts.
  • After installation, ensure that the mechanism is properly adjusted and that the protection system and any manual disconnection devices function properly.
  • Permanently attach the label for the manual disconnection device to the operating element of this device. Only use the remote control when you have a complete view of the gate. If in any doubt, do not operate the system, as it could be damaged.

DESCRIPTION

B1- Content

SCS-sentinel-MBA0054-Swivel-Wing-Gate-Drive-01 SCS-sentinel-MBA0054-Swivel-Wing-Gate-Drive-02

B2- Dimensions

SCS-sentinel-MBA0054-Swivel-Wing-Gate-Drive-03

WIRING/ INSTALLING

Standard installation

SCS-sentinel-MBA0054-Swivel-Wing-Gate-Drive-04

Dimension chart

Comply with the measures shown on the chart for proper installation. Adjust the gate structure to fit it for best automation, if necessary. Before starting the installation, please make sure that the gate moves freely and that:

  1. Hinges are properly positioned and greased.
  2. No any obstacle in the moving area.
  3. No frictions between two gate leaf’s or and on the ground while moving.
  4. Enough space is left when the gate is opening.
    • Distance perpendicularly from gate bolt to the front of fixing bracket #3.
    • Distance from the bolt perpendicular to the surface of articulated arm opener.
    • Distance between the position of arm fixation and the bolt.
    • Installation angle from full closed and full opened position.
Inside opening

Dimension chart

A(mm)| B(mm)| C(mm)| D|
---|---|---|---|---
50| 50| 600| 90 °– 95 °
50| 100| 550| 90 °– 105 °
50| 150| 500| 95 °– 110 °
100| 50| 630| 90 °– 95 °
100| 100| 580| 90 °– 100 °
100| 150| 530| 95 °– 110 °
150| 50| 600| 90 °– 95 °
150| 100| 550| 90 °– 100 °| minimum 50 mm
150| 150| 500| 95 °– 110 °| maximum 200 mm

Motor fixing

  1. Refer to the Dimension Chart to choose the correct dimensions of the motors and position.

  2. Check if the mounting surface of the brackets to be installed is smooth, vertical and rigid.

  3. Arrange the cables for power supply cable of the motors.

  4. Motor installation and setting for mechanical stopper in opened and closed position.

    • Remove the upper cover and mechanical stoppers on the bottom of motor.

    • Place the gate in the full closed position and fix the U-shaped fixing plate on the wall.
      SCS-sentinel-MBA0054-Swivel-Wing-Gate-Drive-05

    • Install the motor on the U-shaped fixing plate with corresponding screws and nuts.

    • After positioning the front of curved arm on the bottom of motor, position the minor arm on the end of curved arm and mounting bracket with corresponding screws and nuts.
      SCS-sentinel-MBA0054-Swivel-Wing-Gate-Drive-06

    • Closed position adjustment: 4.1 Once the full closed position is decided, fix the corresponding mechanical stopper in this position.
      SCS-sentinel-MBA0054-Swivel-Wing-Gate-Drive-07

    • Opened position adjustment: 5.1 Adjust the gate to full opened position and once the position is decided, fix with corresponding mechanical stopper.
      SCS-sentinel-MBA0054-Swivel-Wing-Gate-Drive-08

Emergency release

  1. Insert the release key to the release slot
  2. Turn the release key clockwise
  3. Release and move the gate At the beginning you may notice that the motors are difficult to release. Do not worry, it will disappear with time.

SCS-sentinel-MBA0054-Swivel-Wing-Gate-Drive-10

Permanently attach the label for the manual disconnection device to the operating element of this device.

SCS-sentinel-MBA0054-Swivel-Wing-Gate-Drive-11

Instead of unlock the motor with arms strength, you can use the battery connecting the white and yellow motor cables one way or the other following the polarity to operate the motors. A The white and yellow cables must be L ! 1 disconnected from the electronic card.

Inside opening
Cas n°1

SCS-senACtinel-MBA0054-Swivel-Wing-Gate-Drive-15

Cas n°2

The master and slave motors can be installed on the right or on the left pillar. The master and slave motors can be installed on the right or on the left pillar.

Installing

Power supply connections

Please kindly notice that the operation of power connection should be carried out by a qualified electrician with following steps:

  1. Make sure the gearmotor is not connected to the power supply before the installation is done.
  2. Make sure all the wires are firmly connected.
  3. Supply the gearmotor with the power.

SCS-sentinel-MBA0054-Swivel-Wing-Gate-Drive-17

Wire connection slave motor

SCS-sentinel-MBA0054-Swivel-Wing-Gate-
Drive-18

Photocells (option – ref. AAM0036)

The photocells are safety devices for control automatic gates. Consist of one transmitter and one receiver based in waterproof covers; it is triggered while breaking the path of the beams. If an obstacle is detected, the gate stops and opens again slightly allowing the obstacle to be released safely.

SCS-sentinel-MBA0054-Swivel-Wing-Gate-Drive-19

SCS-sentinel-MBA0054-Swivel-Wing-Gate-Drive-20

SCS-sentinel-MBA0054-Swivel-Wing-Gate-Drive-21

Blinker

SCS-sentinel-MBA0054-Swivel-Wing-Gate-Drive-22

SCS-sentinel-MBA0054-Swivel-Wing-Gate-Drive-23

SETTING USING

D1- Single/double gate setting (dip switch 1) SCS-sentinel-MBA0054
-Swivel-Wing-Gate-Drive-24

DIP SWITCH 1 D/S set :
ON= double gate operation
OFF= single gate operation (connection on MOT 1 l.

D2- Power setting (dip switch 2 et 3)

SCS-sentinel-MBA0054-Swivel-Wing-Gate-Drive-25

Gate auto-close adjustment (dip switch 4) DIP SWITCH 4

«ON»: Active automatic closing in 30 seconds. Simultaneously pressing the two remotes top keys O (opened or closed gate) will turn OFF the automatic mode (the blinker will flash 3 times as confirmation).
Repeat the operation to turn ON the automatic mode (the blinker will flash 3 times as confirmation).
Note : in case of automatic closing, photocells are required.
«OFF»: Automatic closing OFF (caution it will still be possible to turn ON with the remote)

Photocell adjustment (dip switch 5)

DIP SWITCH 5:

ON: Photocells ON. When the photocells detect an obstacle while the gate is closing, the gate stops and opens during 2 seconds.
If the gate auto-close is adjusted, and the photocells detect an obstacle when the gate is totally opened, then the closing time will be reseted.
OFF: Photocells OFF. No detection by the photocells.
D5- Dephasing of the leaves (dip switch 6)

DIP SWITCH 6:
ON: Dephasing in closing/ opening of 8 seconds.
OFF: De phasing in closing/ opening of 3 seconds.

Deceleration speed

LED indication

LED 1 System Learning:
LED1 will be on when remote controls are activated.

LED 2 System learning:
LED 2 blinks twice per second during normal operation and once per second during learning. Static LED2 means incorrect programming.

LED 3 Photocells:
LED 3 will be on when photocells are not aligned or when there’s an obstacle in between.

LED4 start:
LED 4 will be on if the switch of the transmitter, key selector, or the push button is activated.

DB- Remote controls learning process
Press “RF-learn” button for 2 seconds, and the LED1 will be on; then press the transmitter top left button. The LED1 will blink twice and stay on for 10 seconds then be off. And the remote memorize has completed.

D9- System learning process for double leaf gate
The remote control memory storing operation must be over before starting the final system learning.

The LED2 light will remain ON until the system learning process is not over. Let your gate totally opened. Press «SYS-learn» (until the LED2 light begins to flash once every second, instead of twice every second as it normally would), then press the upper-left key for a double gate. The system learning process will be as follows, step by step:

SCS-sentinel-MBA0054-Swivel-Wing-Gate-Drive-27

single gate opening.

TECHNICAL FEATURE

Motor

  • Gear type : 12V DC motor with manual release
  • Supply voltage: electromechanical articulated arm
  • Maximum Gate Weight : 12V DC
  • Maximum Gate Length: 200 kg / 2 m per leaf
  • Operating Temperature: -20°C~+50°C

Blinker

  • Bulb : LED
  • Power cable: 2 x 1 mm2 (not included)
  • Bulb connection: Polarized
  • Screws: Polarized: included
  • Power supply: included
  • Operating temperature : 12 V DC
  • Dimensions: 200 kg / 2 m per leaf
  • 12V DC motor with manual release : 200 kg / 2 m per leaf
  • electromechanical articulated arm : 285 mm x 160 mm x 298 mm

Photocells (option)

  • Detection Method : infrared beam
  • Sensing Range: MAX-10m
  • Input Voltage: 12-24 V AC/DC
  • Response Time: < 100ms
  • Operation Indicator: RX: Red LED On (beam broken)/ Off (beam aligned)
  • TX: Red LED On
  • Dimensions: 63x 63x 30 mm
  • Output Method : relay output

Remote controls

  • Channels: 4
  • Frequency – Maximum transmitted power: 433.92 MHz – power< 10 mw.
  • Power supply: 2 batteries lithium CR2016 included
  • Security: rolling code technology

MAINTENANCE

Conduct the following operations at least every 6 months. If in high intensity of use, shorten the period in between.Disconnect the power supply:

  1.  Clean and lubricate the screws, the pins, and the hinge with grease.
  2. Check the fastening points are properly tightened.
  3.  Make the wire connection are in good condition.

Connect the power supply:

  1. Check the power adjustments.
  2. Check the function of the manual release.
  3. Check the function of photocells or other safety devise.

TECHNICAL ASSISTANCE

Troubleshooting

The leaves suddenly stop during moving

The leaves does not move or only move toward one direction

|

  1. Check if the gate can be moved freely and no obstacles in between.
  2. Make sure the wiring connection of the gear motors is firm.
  3. Make sure the fuse is workable.
  4. Make sure there is no obstacle in the photocells beam.
  5. Cut off the power of the engine. Release the motor and make sure the gate can move freely.

---|---
The master gate closes to the end first and the slave gate stops, which the opening or closing sequence is not being operated properly|

  1. Check if the gate can be moved freely and no obstacles in between.
  2. Make sure the wiring connection of the gear motors is firm.
  3. Make sure the fuse is workable.
  4. Make sure the safety beam are operating properly if installed.
  5. Cut off the power of the engine.Release the motor and make sure the gate can move freely.
  6. Increase the power with the switch 2 & 3.

The gear motors does not run and the relay is noisy when operating the gate opening and

closing

| Check the condition fuse.

WARRANTY

The invoice will be required as proof of purchase date.

Are never covered by our warranty:

  • Damage resulting from the consequences of a bad installation (bad wiring, reverse
    polarity .. .).

  • Damage resulting from improper use of the device (use in contradiction with the
    manuall or its modification.

  • Damage resulting from the consequences of the use of components not from SCS

SENTINEL

  • Damage due to lack of maintenance, physical shock.
  • Damage due to weather: hail, lightning, strong wind etc ..
  • Returns made without a copy of the invoice or receipt.

WARNINGS
Don’t throw batteries or out of order products with the household waste (garbage). The dangerous substances that they are likely to include may harm health or the environment. Make your retailer take back these products or use the selective collect of garbage proposed by your city.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

SCS sentinel User Manuals

Related Manuals