APOSUN CHS9AM UV Monitoring Radiometer User Manual

June 9, 2024
APOSUN

APOSUN CHS9AM UV Monitoring Radiometer

APOSUN-CHS9AM-UV-Monitoring-Radiometer-fig- \(2\)

Appearance of monitor introduction

UV monitor CHS9AM seriesAPOSUN-CHS9AM-UV-Monitoring-Radiometer-fig-
\(3\)

Mode explanation

APOSUN-CHS9AM-UV-Monitoring-Radiometer-fig-
\(4\)

Basic function description

  1. Mega-functional MCU built-in controller with high steady
  2. MIN 48*94 standard contorl plate
  3. 5 units (0.56 inches )LED display
  4. Output industrial standard signals & Convenient used for embeded system
  5. Easily operation for users
  6. Input voltage range :85–265V AC
  7. UV lamp lighting time accumulated automatically
  8. Lighting intensity attenuate 50% off alarming

Safety notice

Herein outputs analog signals inside connected same AGND without isolated.
Analog signals(4-20mA/1-5vdc output value corresponding to the relative alue of UV 0~100%).
Blue cable: Vin-18 /Brown cable:5VDC-19 /Black cable:GND-20APOSUN-
CHS9AM-UV-Monitoring-Radiometer-fig- \(5\)

Port No. Name Function Note
1、2 POWER

POWER INPUT PORTS

|
4、6| NC| NORMAL CLOSED|
5、6| NO| NORMAL OPEN|
7、8| 1-5VDC|

VOLTAGE OUTPUT PORTS

| Port7-GND
9、10| 4-20mA|

CURRENT OUTPUT PORTS

| Port9-GND
18| Vin|

SIGNALS INPUT FOR SENSOR

|
19、20| 5VDC/GND| SENSOR POWER CABLE| POWER PROVIDED BY APPARATUS

Symbol description

Symbol Item Operation Adjust Range Note
C-00 UV

relative value

| Enter in the parameters setting mode,keep pressing the “SET” button lasts 3S.| 100%| Set the UV value as whole referance value in order to monitor the UV lamp attenuation.

C-01

| C-00| Press “SET”enter in the parameters indicate mode,repress SET”button enter in parameters setting mode .Press the “page shift set “button to adjust the unit value .Press the “shift left” button to change the unit needs to adjust .

Setting over ,press the “SET”button lasts for 3s,start device memory and back to standby mode .

|

0-100%

| According the actual requirement , set the lamp low limited warming line .In case the inspected value lower than last value ,warming up and the delay be actived .
C-02| C-00| Page turned to C-02 parameters setting mode , press the “SET”button enter in the parameters indicate mode.Then press the “SET”button enter in the parameters setting mode ,details as same reason as C-01setting .| 0-19999Hours| After set the lamp using time . In actually run time ,when the totally run time exceeds the original setting time .

Warning up and delay be actived .

OPERATION DESCRIPTION

FACE PALTE EXPLANATIONAPOSUN-CHS9AM-UV-Monitoring-Radiometer-fig-
\(6\)

Description:

Press the “page shift set “button ,switchover the display . When switch on the parameters setting plate ,C0-C4 would shown .Then press the “set”button ,then will show nowtime parameters values .Re-press the “set” , enter in the parameters setting mode .The value you setting will falshing ,press the “page set button”to adjust –add or sub.Use the “left shift” button to change the setting unit .After all setting ,press the “SET” button 3s to quit setting mode and return tovalue-shown mode .Press the “page shift set “button return to code-shownmode .Details value names are on the plate .

Convenient for client to zero clearing setting and reset setting operation .The apparatus can up to those functions .

zero clearing
setting enter in the “run time”mode ,press the “SET” button 3S
reset setting
if you need to set thr “UV relative value “up to 100% .enter in the “C-00″mode ,then press the “SET”button and dis-release into the value-shown mode,then press the “SET” button and dis-release into the 100%value-setting mode, three indicators flashing at this time ,press the “SET”button 3S. After above ,the show value set to 100% well and turn back to normal mode

Buttons fuctional operation explanation

SET
Under the parameter settingm mode,valid in UV running mode ,keep pressing 3S to zero clearing.
shift left
Under the parameter settingm mode ,change the unit need to adjust .the flashing unit can be change.”shift left” button is circle run .Invalid in other modes

Page shift left

  1. Under the parameter settingm mode,press the button to change the show mode just as parameters or codes modes .
  2. Under the parameter settingm mode,press the button back to parameters code mode .
  3. Under the parameter settingm mode,press the button back to parameters value mode .

Combination :

Under the parameter settingm mode,press the “SET” +”page shift left”buttons can back to parameters code mode without record the setting parameters

Display plate and operation processing

press the “page shift left”button to circle display the interface step 1 to 9 APOSUN-CHS9AM-UV-Monitoring-Radiometer-fig- \(7\) APOSUN-CHS9AM-UV-Monitoring-Radiometer-fig- \(8\)

Parameters adjustment steps (for parameters C-00 ):

Step ① to ⑦ for C-00 parameters settingAPOSUN-CHS9AM-UV-Monitoring-
Radiometer-fig- \(9\)

Parameters adjustment steps (for parameters C-01 ):

Step ① to ⑦ for C-01 parameters settingAPOSUN-CHS9AM-UV-Monitoring-
Radiometer-fig- \(10\)

Parameters adjustment steps for C-02 same as above C-01 setting steps.

Function settings

Symbol Item Operation Adjust Range Note
C-00 UV

relative value

| Enter in the parameters setting mode,keep pressing the “SET” button lasts 5S.| 100%| Set the UV value as whole referance value in order to monitor the UV lamp attenuation.


C-01

| C-00| Press “SET”enter in the parameters indicate mode,repress SET”button enter in parameters setting mode .Press the “page shift set “button to adjust the unit value .

Press the “shift left” button to change the unit needs to adjust . Setting over ,press the “SET”button lasts for 5s,start device memory and back to standby mode .

| ****

0-100%

| ****

According the actual requirement ,set the lamp low limited warming line .In case the inspected value lower than last value ,warming up and the delay be actived .

C-02| C-00| Page turned to C-02 parameters setting mode , press the “SET”button enter in the parameters indicate mode.Then press the “SET”button enter in the parameters setting mode ,details as same as C-01setting .| 0-19999Hours| After set the lamp using time .In actually run time ,when the totally run time exceeds the original setting time .Warning up and delay be actived .

Defective codes explanation

Symbol Item Description Defects elimination
E-01 UV low limited

warning

| As the UV relative value down to 50% of original seetings , device be warning .| 1D.  etector may be dirty,  please do clearing

2.The intensity of illumination may be weak ,please replace the lamp.

E-02| UV lighting period exceeded warning| As the UV run time exceed to original seetings run-time , device be warning .|

Replace lamp

Dimension of appearance