Buttons and LCD display
Turning ON/OFF Your Thermostat
Press button to turn the thermostat ON or OFF. When thermostat is turned off,
LCD will display OFF.
Configuration Menu
This thermostat is full of useful features which can be set quite easily through the feature configuration menu. To access the feature configuration menu, simply turn off your thermostat and hold button M for 5 seconds. Now you can see Menu 1, to proeceed to other menu, press button M again. To exit menu, press button .
Menu #| Feature Description| Factory Default
Feature Value| Press or to select
---|---|---|---
1| Sensor selection. This thermostat is a combination model allowing you to
choose between 3 different models. (A, AF,F )
A model: air onl y, with built in sensor
AF model: air & floo r , with both built in and remote sensor F model: floor onl y, with remote sensor
| A| A / AF / F
2| Switching differential. The number of degrees difference between switching
off at the set temperature and on again to reach the set temperature.The
default is 1°C which means the thermostat will switch the heating on 0.5°C
below the set temperature and will turn it off 0.5°C above the set
temperature. With a 2°C differential, the heating will switch on 1°C below the
set temperature and switch off 1°C above the set temperature.| 1°C| 1°C ~ 5°C
3
| Calibrate the room temperature. This feature is used to compensate for any difference between the displayed room temperature and a thermometer.| 0°C| -5°C ~ +5°C
4
| Calibrate the floor temperature. This feature is used to compensate for any difference between the displayed floor temperature and a thermometer.| 0°C| -5°C ~ +5°C
5
| Pump protection(for hydronic heating only). In hydronic heating
installations, it is recommended to activate the pump at least 15 seconds
every 24 hours in order to avoid any seizing. Select ON to activate this
feature, OFF to deactivate. When the thermostat is activating the pump, the
icon will blink.| OFF| ON / OFF
6| Optimum start(preheat). This feature is to ensure that the required
temperature has already been reached when you get up in the morning or come
home from work.| OFF| ON / OFF
7| Set the floor temperature limit. This feature is to protect the floor
surface.| 40 °C| 20°C ~ 40 °C
8
| Set backlight turning-on time. Selecting on will turn the light on
continuously. Selecting off will turn the light off. Selecting 20 seconds will
turn the light on for 20 seconds.| 20 seconds| 20 seconds / ON /OFF
9| Select temperature format °C or °F.| °C| °C / °F
10| Select 12 / 24 hour clock| 24| 12 / 24
11| Frost protection. This feature is to avoid room temperature going below 5
°C| OFF| ON / OFF
12| Program type selection. This gives user 3 options of program type.
5_2 will give you 5 days(Monday to Fiday) with the same six events(Wakeup, out, home, out, home,sleep) and 2 days(Saturday and Sunday) with the same six events.
6_1 will give you 6 days(Monday to Saturday) with the same six events(Wakeup, out, home, out,home,sleep) and 1 day(Sunday) with the same six events.
7_0 will give you individual settings for each day from Monday to Sunday.
| 7_0| 5_2 / 6_1 / 7_0
Error Message
- E0 = The internal sensor has developed a fault. You should contact your thermostat retailer for assistance.
- E1 = The remote floor sensor has not been connected, has been wired incorrectly or the probe is faulty.
- LO = The room or floor temperature is below 0 °C.
- HI = The room or floor temperature is above 50 °C.
SETTING
Auto / Manual Mode
Press button M to select Auto/Manual mode. In Manual mode, the thermostat
maintains a constant set temperature manually set by the user. In Auto mode,
the thermostat executes the preprogrammed schedules. To adjust these
schedules, follow the easy steps below,
Program your thermostat
- Press and hold button M for 5 seconds until “Program” is shown with the Day flashing. Use up or down button adjust the day (hold up or down button for 5 seconds to set all days the same).
- Press button M to bring up the program 1. Use up or down button to set the start time (default 06:30).(Hold up or down button to change by 15 minutes each time.)
- Press button M again and use up or down button to set the desired temperature to be maintained for program 1.(default 21 °C)
2 Repeat and 3 unitl you finish the settings for 6 programmes. Press
button M to accept and exit.
The below is the default factory settings for the 6 programmes.
Program | Start time | Setpoint |
---|---|---|
1 | 06:30 | 21°C |
2 | 08:30 | 16°C |
3 | 11:30 | 16°C |
4 | 13:00 | 16°C |
5 | 16:30 | 21°C |
6 | 22:30 | 16°C |
Note: It is faster to program the same schedule for the entire week and then to adjust the exceptional days.
- To skip program 3 and 4, simply adjust the set temperature for program 3 and 4 to the same set temperature as program 2.
- To skip program 2 ,3,4,5 for Saturday and Sunday, simply adjust the set temperature for program 2 ,3,4,5 to the same set temperature as program 1.
Set the Time and Day
This thermostat is fitted with a real time clock. It is essential that the
clock time and day are set accurately if you require your programmed events to
start on time. Follow the below easy steps,
- Step 1. Press the button once and the time will flash
- Step 2. Use up or down button to change the time (Hold up or down button to change by 15 minutes each time.)
- Step 3. Press button again, the day of the week will flash
- Step 4. Use up or down button to change the day of the week
- Step 5. Press button again to accept and exit
Resetting factory defaults
Your thermostat has the ability to reset all settings to the factory
defaults. If you are certain you want to do this: In standby mode(when
thermostat is turned off), press and hold button M and for 5 seconds until
“RES” is shown for 5 seconds on LCD.
Lock the buttons
To lock the buttons, press and hold the up and down buttons for 5 seconds
until you see a lock icon appearing, to unlock, repeat the steps above.
View floor temperature
If thermostat is set in AF model, press and hold the down button for 5
seconds, floor temperature will show and it will automatically revert back to
room temperature in 5 seconds.
Temporary temperature override
To temporary override the current set temperature,
- Press up or down button once, the set temperature starts flashing
- Press up or down button again until the temperature you want is displayed
- Press to confirm the setting with “ Temporary ” shown on LCD
Now your thermostat will override the current programming and maintain the new
set temperature until the next program period begins. To cancel the override
setting, press
and hold button for 5 seconds until disappears.“ Temporary ”
Vacation mode
To set vacation mode press and hold the up button for 5 seconds until
appears. Use same procedure to exit this mode.Vacation mode will maintain a
set temperature(default 10°C) all the time. Press up or down button to change
the set point and wait for 5 seconds to accept and exit.
WARNING
- Please ensure that the electrical wiring of the installation and connections to and from the thermostat and any remote sensor connected to it are in accordance with BS 7671, the latest edition of the IET Wiring Regulations.
- The thermostat must be wired to the electric mains through a switch capable of disconnecting all poles compliant with the current safety standards and with a contact separation of at least 3 mm in all poles.
- Before commencing work on the installation, the electricity supply must be disconnected.
- The depth of the back box should be 35mm minimum.
Installation and Wiring
Dimensions