INSTALLATION
INSTALLATION OF EMBEDDED GATE
- Unpack the gate.
- Allow a depth of 50 cm for the embedding.
- The clearance under the gate must be 10 cm.
- Pour 15 cm of concrete into the bottom of the hole.
- Embed the post by filling the holes to the top.
INSTALLATION OF base-plated gate
- Cut the posts to length. Leave a space under the gate leaf of 10 cm and cut out the bottom of the post.
- Re-paint the bottom of the post.
- Drill 9 mm diameter holes for screws using the drilling template (next page).
- Place the bracket mounted on the plate in the post.
- Tighten the post and the plate with a washer and an M8x20 screw.
- Installation template-scale1: 1
ASSEMBLY
ASSEMBLY OF THE HANDLE
- Insert the handle into the lock.
- Insert the screw into the handle.
ASSEMBLY OF THE HINGES
- Top hinge: put the « shaft » towards the bottom.
- Bottom hinge: put the « shaft » towards the top.
CHANGING THE DIRECTION OF OPENING
INSTALLATION OF THE STRIKE-PLATE
- Install your strike plate with the edges on one side or the other, depending on your choice of opening direction.
- Screw in the strike plate.
INVERTING THE LATCH
- Remove the lock by unscrewing the 2 screws that hold the lock.
- First method
- Put a flat screwdriver into the groove, push and pivot the latch 180°.
- 2nd method
- Push the cleat to extend the latch
- Turn the latch
- Push the latch back in
PUTTING THE LOCK BACK INTO PLACE
- Put back the lock
- Tighten up the two screws that hold the lock.