OERLIKON CITOLINE I300 Playmaker Of The Workshop User Manual
- June 9, 2024
- OERLIKON
Table of Contents
- Introduction
- Technical Specifications
- ECO design information
- Electromagnetic Compatibility (EMC)
- Safety
- Introduction
- Installation and Operator Instructions
- Controls and Operational Features
- Welding SMAW Process
- Welding GMAW, FCAW Process
- Welding GMAW Process in synergic mode
- Loading the Electrode Wire
- Adjustments of Brake Torque of Sleeve
- Adjusting of Force of Pressure Roll Force
- Inserting Electrode Wire into Welding Torch
- Changing Driving Rolls
- Gas Connection
- Transport & Lifting
- Maintenance
- Customer Assistance Policy
- WEEE
- Spare Parts
- REACh
- Authorized Service Shops Location
- Electrical Schematic
- Accessories
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
OERLIKON CITOLINE I300 Playmaker Of The Workshop
Introduction
THANK YOU! For choosing the QUALITY of the Lincoln Electric products.
- Please check packaging and equipment for damage. Claims for material damaged in shipment must be notified immediately to the dealer.
- For ease of use, please enter your product identification data in the table below. Model Name, Code & Serial Number can be found on the machine rating plate.
Technical Specifications
NAME | INDEX |
---|---|
CITOLINE i250 | W100000317 |
CITOLINE i300 | W100000318 |
INPUT
| Input Voltage U1| EMC Class| Frequency
CITOLINE i250| 400V ± 10%, 3-phase| A| 50/60Hz
CITOLINE i300
| Process| Input Power at Rated Cycle (40°C)| Input Amperes I1max| PF
CITOLINE i250| GMAW/FCAW| 12,8 kVA @ 35% Duty Cycle| 18,2 A| 0,61
SMAW| 14 kVA @ 35% Duty Cycle| 19,8 A| 0,62
CITOLINE i300| GMAW/FCAW| 15 kVA @ 35% Duty Cycle| 22,0 A| 0,65
SMAW| 14 kVA @ 35% Duty Cycle| 19,8 A| 0,62
RATED OUTPUT
| Process| Open Circuit Voltage| Duty Cycle 40°C (based on a 10 min. period)|
Output Current
| ****
Output Voltage
CITOLINE i250| GMAW| 72Vdc| 35%| 250A| 26,5Vdc
60%| 230A| 25,5Vdc
100%| 175A| 22,8Vdc
FCAW| 35%| 250A| 26,5Vdc
60%| 230A| 25,5Vdc
100%| 175A| 22,8Vdc
SMAW| 35%| 250A| 30Vdc
60%| 190A| 27,6Vdc
100%| 150A| 26Vdc
CITOLINE i300| GMAW| 72Vdc| 35%| 300A| 29Vdc
60%| 230A| 25,5Vdc
100%| 175A| 22,8Vdc
FCAW| 35%| 300A| 29Vdc
60%| 230A| 25,5Vdc
100%| 175A| 22,8Vdc
SMAW| 35%| 250A| 30Vdc
60%| 190A| 27,6Vdc
100%| 150A| 26Vdc
WELDING CURRENT RANGE
| GMAW| FCAW| SMAW
CITOLINE i250| 50A÷250A| 50A÷250A| 10A÷250A
CITOLINE i300| 50A÷300A| 50A÷300A| 10A÷250A
RECOMMENDED INPUT CABLE AND FUSE SIZES
| Fuse Type gR or Circuit Breaker Type D| Power Lead
CITOLINE i250| 16A, 400V AC| 4 Conductor, 2,5mm2
CITOLINE i300| 16A, 400V AC| 4 Conductor, 2,5mm2
WELDING VOLTAGE REGULATION RANGE
| GMAW| FCAW
CITOLINE i250| 16,5 V ÷ 26,5 V| 16,5 V ÷26,5 V
CITOLINE i300| 16,5 V ÷29 V| 16,5 V ÷29 V
WIRE FEED SPEED RANGE / WIRE DIAMETER
| WFS Range| Drive Rolls| Drive roll diameter
CITOLINE i250| 1.5 ÷ 18m/min| 4| Ø30
CITOLINE i300
| Solid Wires| Aluminum Wires| Cored Wires
CITOLINE i250| 0.6 ÷ 1.2 mm| 1.0 ÷ 1.2 mm| 0.8 ÷ 1.0 mm
CITOLINE i300
DIMENSION
| Weight| Height| Width| Length
CITOLINE i250| 50 kg| 760 mm| 395 mm| 830 mm
CITOLINE i300| 50 kg
OTHERS
| Protection Rating| Maximum Gas Pressure| Operating Humidity (t=20°C)
CITOLINE i250| IP23| 0,5MPa (5 bar)| ≤ 90 %
CITOLINE i300
| Operating Temperature| Storage Temperature|
CITOLINE i250| from -10°C to +40°C| from -25°C to 55°C|
CITOLINE i300
ECO design information
The equipment has been designed in order to be compliant with the Directive
2009/125/EC and the Regulation 2019/1784/EU.
Efficiency and idle power consumption:
Index| Name| Efficiency when max power consumption
/ Idle power consumption| Equivalent model
---|---|---|---
W100000317| CITOLINE i250| 86% / 23W| No equivalent model
W100000318| CITOLINE i300| 86% / 23W| No equivalent model
Idle state occurs under the condition specified in below table
IDLE STATE
Condition| Presence
MIG mode| X
TIG mode|
STICK mode|
After 30 minutes of non-working|
Fan off| X
The value of efficiency and consumption in idle state have been measured by
method and conditions defined in the product standard EN 60974-1:20XX.
Manufacturer’s name, product name, code number, product number, serial number
and date of production can be read from rating plate.
Where
- Manufacturer name and address
- Product name
- Code number
- Product number
- Serial number
- 5A- country of production
- 5B- year of production
- 5C- month of production
- 5D- progressive number different for each machine
Typical gas usage for MIG/MAG equipment:
Material type| Wire diameter [mm]| DC electrode
positive| Wire Feeding [m/min]| Shielding Gas| Gas flow
[l/min]
---|---|---|---|---|---
Current [A]| Voltage [V]
Carbon, low alloy steel| 0,9 ÷ 1,1| 95 ÷ 200| 18 ÷ 22| 3,5 – 6,5| Ar 75%, CO2
25%| 12
Aluminium| 0,8 ÷ 1,6| 90 ÷ 240| 18 ÷ 26| 5,5 – 9,5| Argon| 14 ÷ 19
Austenic stainless steel| 0,8 ÷ 1,6| 85 ÷ 300| 21 ÷ 28| 3 – 7| Ar 98%, O2 2% /
He 90%, Ar 7,5% CO2 2,5%| 14 ÷ 16
Copper alloy| 0,9 ÷ 1,6| 175 ÷ 385| 23 ÷ 26| 6 – 11| Argon| 12 ÷ 16
Magnesium| 1,6 ÷ 2,4| 70 ÷ 335| 16 ÷ 26| 4 – 15| Argon| 24 ÷ 28
TIG Process:
In TIG welding process, gas usage depends on cross-sectional area of the
nozzle. For commonly used torches:
Helium: 14-24 l/min
Argon: 7-16 l/min
Notice: Excessive flow rates causes turbulence in the gas stream which
may aspirate atmospheric contamination into the welding pool.
Notice: A cross wind or draft moving can disrupt the shielding gas
coverage, in the interest of saving of protective gas use screen to block air
flow.
End of life
At end of life of product, it has to be disposal for recycling in accordance
with Directive 2012/19/EU (WEEE), information about the dismantling of product
and Critical Raw Material (CRM) present in the product, can be found at
https://www.lincolnelectric.com/en-gb/support/Pages/operator-manuals-eu.aspx
Electromagnetic Compatibility (EMC)
This machine has been designed in accordance with all relevant directives and standards. However, it may still generate electromagnetic disturbances that can affect other systems like telecommunications (telephone, radio, and television) or other safety systems. These disturbances can cause safety problems in the affected systems. Read and understand this section to eliminate or reduce the amount of electromagnetic disturbance generated by this machine.
This machine has been designed to operate in an industrial area. To operate in a domestic area it is necessary to observe particular precautions to eliminate possible electromagnetic disturbances. The operator must install and operate this equipment as described in this manual. If any electromagnetic disturbances are detected the operator must put in place corrective actions to eliminate these disturbances, if necessary with assistance from Lincoln Electric.
WARNING
Provided that the public low voltage system impedance at the point of common coupling is lower than:
- 58 mΩ for the CITOLINE i250
- 59,9 mΩ for the CITOLINE i300
This equipment is compliant with IEC 61000-3-11 and IEC 61000-3-12 and can be connected to public low voltage systems. It is the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the system impedance complies with the impedance restrictions.
Before installing the machine, the operator must check the work area for any devices that may malfunction because of electromagnetic disturbances. Consider the following.
- Input and output cables, control cables, and telephone cables that are in or adjacent to the work area and the machine.
- Radio and/or television transmitters and receivers. Computers or computer controlled equipment.
- Safety and control equipment for industrial processes. Equipment for calibration and measurement.
- Personal medical devices like pacemakers and hearing aids.
- Check the electromagnetic immunity for equipment operating in or near the work area. The operator must be sure that all equipment in the area is compatible. This may require additional protection measures.
- The dimensions of the work area to consider will depend on the construction of the area and other activities that are taking place.
Consider the following guidelines to reduce electromagnetic emissions from the machine.
- Connect the machine to the input supply according to this manual. If disturbances occur if may be necessary to take additional precautions such as filtering the input supply.
- The output cables should be as short as possible and positioned together as close as possible to each other. If possible connect the work piece to ground in order to reduce the electromagnetic emissions. The operator must check that connecting the work piece to ground does not cause problems or unsafe operating conditions for personnel and equipment.
- Shielding of cables in the work area can reduce electromagnetic emissions. This may be necessary for special applications.
WARNING
EMC classification of this product is class A in accordance with electromagnetic compatibility standard EN 60974-10 which means that the product is designed to be used in an industrial environment only.
WARNING
The Class A equipment is not intended for use in residential locations where
the electrical power is provided by the public low-voltage supply system.
There may be potential difficulties in ensuring electromagnetic compatibility
in those locations, due to conducted as well as radiated disturbances.
Safety
WARNING
This equipment must be used by qualified personnel. Be sure that all installation, operation, maintenance and repair procedures are performed only by qualified person. Read and understand this manual before operating this equipment. Failure to follow the instructions in this manual could cause serious personal injury, loss of life, or damage to this equipment. Read and understand the following explanations of the warning symbols. Lincoln Electric is not responsible for damages caused by improper installation, improper care or abnormal operation.
**| WARNING: This symbol indicates that instructions must be followed
to avoid serious personal injury, loss of life, or damage to this equipment.
Protect yourself and others from possible serious injury or death.
---|---
| READ AND UNDERSTAND INSTRUCTIONS: Read and understand this manual
before operating this equipment. Arc welding can be hazardous. Failure to
follow the instructions in this manual could cause serious personal injury,
loss of life, or damage to this equipment.
| ELECTRIC SHOCK CAN KILL: Welding equipment generates high voltages. Do
not touch the electrode, work clamp, or connected work pieces when this
equipment is on. Insulate yourself from the electrode, work clamp and
connected work pieces.
| ELECTRICALLY POWERED EQUIPMENT: Turn off input power using the
disconnect switch at the fuse box before working on this equipment. Ground
this equipment in accordance with local electrical regulations.
| ELECTRICALLY POWERED EQUIPMENT: Regularly inspect the input, electrode,
and work clamp cables. If any insulation damage exists replace the cable
immediately. Do not place the electrode holder directly on the welding table
or any other surface in contact with the work clamp to avoid the risk of
accidental arc ignition.
| ELECTRIC AND MAGNETIC FIELDS MAY BE DANGEROUS: Electric current
flowing through any conductor creates electric and magnetic fields (EMF). EMF
fields may interfere with some pacemakers and welders having a pacemaker shall
consult their physician before operating this equipment.
| CE COMPLIANCE: This equipment complies with the European Community
Directives.
| ARTIFICIAL OPTICAL RADIATION: According with the requirements in
2006/25/EC Directive and EN 12198 Standard, the equipment is a category 2. It
makes mandatory the adoption of Personal Protective Equipment (PPE) having
filter with a protection degree up to a maximum of 15, as required by EN169
Standard.
| FUMES AND GASES CAN BE DANGEROUS: Welding may produce fumes and gases
hazardous to health. Avoid breathing these fumes and gases. To avoid these
dangers the operator must use enough ventilation or exhaust to keep fumes and
gases away from the breathing zone.
| ARC RAYS CAN BURN: Use a shield with the proper filter and cover plates
to protect your eyes from sparks and the rays of the arc when welding or
observing. Use suitable clothing made from durable flame-resistant material to
protect you skin and that of your helpers. Protect other nearby personnel with
suitable, non-flammable screening and warn them not to watch the arc nor
expose themselves to the arc.
| WELDING SPARKS CAN CAUSE FIRE OR EXPLOSION:** Remove fire hazards
from the welding area and have a fire extinguisher readily available. Welding
sparks and hot materials from the welding process can easily go through small
cracks and openings to adjacent areas. Do not weld on any tanks, drums,
containers, or material until the proper steps have been taken to insure that
no flammable or toxic vapors will be present. Never operate this equipment
when flammable gases, vapors or liquid combustibles are
present.
| WELDED MATERIALS CAN BURN: Welding generates a large amount of heat.
Hot surfaces and materials in work area can cause serious burns. Use gloves
and pliers when touching or moving materials in the work area.
| CYLINDER MAY EXPLODE IF DAMAGED: Use only compressed gas cylinders
containing the correct shielding gas for the process used and properly
operating regulators designed for the gas and pressure used. Always keep
cylinders in an upright position securely chained to a fixed support. Do not
move or transport gas cylinders with the protection cap removed. Do not allow
the electrode, electrode holder, work clamp or any other electrically live
part to touch a gas cylinder. Gas cylinders must be located away from areas
where they may be subjected to physical damage or the welding process
including sparks and heat sources.
| A GAS CYLINDER can be
used with this machine. In this case, place the gas cylinder on the back of
the machine on the shelf intended for this and secure it by attaching it to
the machine with chains. The height of the cylinder cannot exceed 1.65m.
| MOVING PARTS ARE DANGEROUS: There are moving mechanical parts in this
machine, which can cause serious injury. Keep your hands, body and clothing
away from those parts during machine starting, operating and servicing.
| SAFETY MARK: This
equipment is suitable for supplying power for welding operations carried out
in an environment with increased hazard of electric shock.
The manufacturer reserves the right to make changes and/or improvements in design without upgrade at the same time the operator’s manual.
Introduction
The welding machines CITOLINE i250 and CITOLINE i300 can be used for welding in below methods:
- GMAW
- FCAW
- SMAW
The complete package contains:
- Work lead with ground clamp – 3m,
- Gas hose – 2m,
- Drive roll V0.8/1.0 for solid wire (assembly in the wire feeder).
Recommended equipment, which can be bought by user, was mentioned in the chapter “Accessories”.
Installation and Operator Instructions
Read this entire section before installation or operation of the machine.
Location and Environment
This machine will operate in harsh environments.
However, it is important that simple preventative measures are followed to
assure long life and reliable operation.
- Do not place or operate this machine on a surface with an incline greater than 10° from horizontal.
- Do not use this machine for pipe thawing.
- This machine must be located where there is free circulation of clean air without restrictions for air movement to and from the air vents. Do not cover the machine with paper, cloth or rags when switched on.
- Dirt and dust that can be drawn into the machine should be kept to a minimum.
- This machine has a protection rating of IP23. Keep it dry when possible and do not place it on wet ground or in puddles.
- Locate the machine away from radio controlled machinery. Normal operation may adversely affect the operation of nearby radio controlled machinery, which may result in injury or equipment damage. Read the section on electromagnetic compatibility in this manual.
- Do not operate in areas with an ambient temperature greater than 40°C.
Duty cycle and Overheating
The duty cycle of a welding machine is the percentage of time in a 10 minute
cycle at which the welder can operate the machine at rated welding current.
Example: 60% duty cycle
Excessive extension of the duty cycle will cause the thermal protection
circuit to activate.
Input Supply Connection
WARNING
Only a qualified electrician can connect the welding machine to the supply network. Installation had to be made in accordance with the appropriate National Electrical Code and local regulations.
Check the input voltage, phase and frequency supplied to this machine before
turning it on. Verify the connection of ground wires from the machine to the
input source. The welding machine CITOLINE i250, CITOLINE i300, must be
connected to a correctly installed plug-in socket with an earth pin.
Input voltage is three-phase 400VAC, 50/60Hz. For more information about input
supply refer to the technical specification section of this manual and to the
rating plate of the machine.
Make sure that the amount of mains power available from the input supply is
adequate for normal operation of the machine. The necessary delayed fuse (or
circuit breaker with “D” characteristic) and cable sizes are indicated in the
technical specification section of this manual.
WARNING
The welding machine can be supplied from a power generator of output power at least 30% larger than input power of the welding machine.
WARNING
When powering welder from a generator be sure to turn off welder first, before generator is shut down, in order to prevent damage to welder!
Output Connections
Refer to points [1], [3] and [4] of the figures below.
Controls and Operational Features
-
EURO Socket: For connecting a welding gun (for GMAW / FCAW processes).
-
Lead of Changing Polarity of EURO socket.
-
Positive Output Socket for the Welding Circuit: For connecting an electrode holder with lead / work lead depending on the require configuration.
-
Negative Output Socket for the Welding Circuit: For connecting an electrode holder with lead / work lead depending on the require configuration.
-
User Interface: See “User Interface” chapter.
-
Gas Connector: Connection for gas line.
-
Power Switch ON/OFF (I/O): Controls the input power to the machine. Be sure the power source is connected to the mains supply before turning power on (“I”).
-
Power Lead (3,4m): Connect the supply plug to the existing input cable that is rated for the machine as indicated in this manual, and conforms to all applicable standards. This connection shall be performed by a qualified person only.
-
Spooled Wire (for GMAW / FCAW): Not supplied as standard.
-
Wire Spool Holder: Maximum 15kg spools. Maximum 300mm diameter spools. Holder allows mounting plastic, steel and fiber spools onto 51 mm spindle.
Note: Plastic Brake Nut has a Left-hand thread. -
Wire drive: 4-rolls wire drive.
-
Switch: Cold Inch / Gas Purge: This switch allows wire feeding (wire test) and gas flow (gas test) without switching on the output voltage.
-
Thermal Overload Indicator: It indicates that the machine is overloaded or that the cooling is not sufficient. Displays show: “ALA ot” = Alarm Over Temperature message.
-
Input Power Indicator: This LED lights up when the welding machine is ON and is ready to work.
-
Left Display: Shows wire feed speed or welding current. During welding shows the actual welding current value.
-
Output Current LED Indicator: Informs that the Left Display shows the output current in ampere.
-
Wire Feed Speed LED Indicator: Informs that the Left Display shows the wire feed speed in m/min.
-
Right Display: Depending on the selected function and the welding program shows the welding voltage in volts or value of Arc Force. During welding shows the actual output welding voltage.
-
Inductance Control: Adjusts the hardness of the arc. A low value (1-4) makes the arc harder (more spatter), while a high value (8-10) produces a softer arc (less spatter). Adjustment range: 0 to +10.
-
Wire Diameter or Manual Mode Selection Button: Sets the diameter of the welding wire for Synergic Mode or choose Manual Mode.
Process| Symbol| Description
---|---|---
| 0.6| Available wire diameter depends on choosing gas shielding type, type of wire and welding wire material.
0.8
0.9
1.0
1.2
| The machine works in Manual mode. Welding parameters (wire feed speed and voltage) are selected by the user. -
Wire Material Selection Button: sets the type of wire materials (for Synergic Mode only):
Process| Symbol| Description
---|---|---
| Fe| Steel
Al| Aluminum
SS| Stainless steel -
Burnback Time Selection Button – for Synergic and Manual Mode, allow to choose and set burn back time:
Process| Symbol| Description
---|---|---
| | Burn back Time – amount of time that the welding is continued after the wire stops feeding. It prevents the wire from sticking in the puddle and prepares the end of the wire for the next arc ignition.- Regulation range: from 0,02 to 0,25 seconds.
- Regulation range: from 0,02 to 0,25 seconds.
-
Welding Wire Type Selection Button: Set welding wire type (for Synergic Mode only):
Process| Symbol| Description
---|---|---
| Solid|- For Synergic Mode only
- Gas shield required
Flux Cored
-
Run-In WFS Button: Allow to show and set the Run-in wire feed speed value (for Synergic and Manual Mode):
Process| Symbol| Description
---|---|---
| | Run-in WFS – sets the wire feed speed from the time the trigger is pulled until an arc is established.- Adjust range: from 20 to 100 percent of the WFS value.
- When Run-In value is more than max WFS, machine keep max WFS.
-
Gas Selection Button: Enables the selection of the type of shielding gas (for Synergic Mode only).
Process| Symbol| Description
---|---|---
| CO2| To choose gas shielding.
MIX
Ar -
Selection Button to Display Work point as WFS or A: Allows to change the operating point display as wire feed speed (WFS) in [m/min] or as an output current value in [A]. Only available in synergic mode.
Process| Symbol| Description
---|---|---
| | Work point values are displayed in m/min.
| Work point values are displayed as an amperage [A]. -
Torch Trigger Mode Button (2-Step/4-Step): Change the function of the torch trigger.
Process| Symbol| Description
---|---|---
| | 2-Step trigger operation turns welding on and off as direct response to the trigger. Welding process starts when the torch trigger is press.
| 4-Step mode allows to continue welding, when the torch trigger is released. To stop welding, the torch trigger should be pressed again.4-step model facilitates to make long welds.
-
Welding Process Selection Button: Allow to choose the welding process:
Symbol| Description
---|---
| GMAW/FACW welding mode.
| SMAW welding mode. -
The Center Control: Sets the value shown on the right display. Depending on welding processes or selected function can be set:
Process| Symbol| Description
---|---|---
| | The welding voltage (also during welding).
| | Burn back Time-
Adjust range: from 0.02 to 0.25 seconds
| | Run-in WFS -
Adjust range: from 20 to 100 percent of the WFS value.
| | ARC FORCE, the output current is temporarily increased to clear short circuit connections between the electrode and the workpiece. Lower values will provide less short circuit current and a softer arc. Higher settings will provide a higher short circuit current, a more forceful arc and possibly more spatter. -
Adjust range: from 0 to 100.
-
-
Left Control: Sets the value shown on the left display. Depending on welding process can be set:
Process| Mark| Description
---|---|---
| | Work point values are displayed in m/min.
| | Work point values are displayed as an amperage [A].
Welding SMAW Process
CITOLINE i250, CITOLINE i300 does not include the electrode holder with lead necessary for SMAW welding, but the one can be purchased separately.
Procedure of begin welding of SMAW process:
- First turn the machine off.
- Determine the electrode polarity for the electrode to be used. Consult the electrode data for this information.
- Depending on the polarity of using electrode, connect the work lead and the electrode holder with lead to output socket [3] or [4] and lock them. See the Table 1.
Table 1.
| | | Output socket
---|---|---|---
POLARITY| DC (+)| The electrode holder with lead to SMAW| [3]|
Work lead| [4]| **
DC (-)| The electrode holder with lead to SMAW| [3]| **
Work lead| [4]| ****
- Connect the work lead to the welding piece with the work clamp.
- Install the proper electrode in the electrode holder.
- Turn the welding machine on.
- Set welding mode to SMAW.
- Set the welding parameters.
- The welding machine is now ready to weld.
- By applying the principle of occupational health and
- safety at welding, welding can be begun.
User can set functions:
- The welding current
- Arc dynamics ARC FORCE
Welding GMAW, FCAW Process
CITOLINE i250, CITOLINE i300 can be used to welding GMAW, FCAW-GS, FCAW-SS
process.
NOTE: Welding FCAW-SS process is possible in Manual Mode only.
In CITOLINE i250, CITOLINE i300 can be set:
- Wire Feed Speed, WFS
- The welding voltage
- Burn back Time
- Run-in WFS
- 2-Step/4-Step
- Polarization DC+/DC-
- Inductance
Preparation the Machine for Welding GMAW and FCAW Process.
Procedure of welding in GMAW or FCAW process:
- Determine the wire polarity for the wire to be used. Consult the wire data for this information.
- Connect output the gas-cooled gun to GMAW / FCAW process to Euro Socket [1].
- Depending on the using wire, connect the work lead to output socket [3] or [4]. See the Table 2.
Table 2
| | | Output socket
---|---|---|---
POLARITY| DC (+)| Lead of Changing Polarity [2]| [3]|
Work lead| [4]| **
DC (-)| Lead of Changing Polarity [2]| [3]|
Work lead| [4]| **
- Connect the work lead to the welding piece with the work clamp.
- Install the proper wire.
- Install the proper drive roll.
- Make sure, if it is needed (GMAW, FCAW-GS processes), that the gas shield has been connected.
- Turn the machine on.
- Push the Cold Inch Switch [12] to feed the wire through the gun liner until the wire comes out of the threaded end.
- Install a proper contact tip.
- Check gas flow with Gas Purge Switch [12] – GMAW and FCAW processes.
- Close the left side panel.
- Set welding mode to GMAW
- The welding machine is now ready to weld.
- By applying the principle of occupational health and safety at welding, welding can be begun.
Welding GMAW Process in synergic mode
In synergic mode, the welding load voltage is not set by user. The correct welding load voltage will set by the machine’s software.
The optimum output welding voltage is automatically set by the machine when changing the wire feed speed m/min or the output current value in A, depending on the selected work point. Table 3 below show all available synergic welding programs.
Wire Diameter | Wire type | Wire Material | Gas Type |
---|---|---|---|
0.6 | Solid | Fe | CO2 |
0.8 | Solid | Fe | CO2 |
0.9 | Solid | Fe | CO2 |
1.0 | Solid | Fe | CO2 |
1.2 | Solid | Fe | CO2 |
0.6 | Solid | Fe | MIX |
0.8 | Solid | Fe | MIX |
0.9 | Solid | Fe | MIX |
1.0 | Solid | Fe | MIX |
1.2 | Solid | Fe | MIX |
0.8 | Solid | Ss | MIX |
0.9 | Solid | Ss | MIX |
1.0 | Solid | Ss | MIX |
1.2 | Solid | Ss | MIX |
0.8 | Flux-Cored | Fe | CO2 |
0.9 | Flux-Cored | Fe | CO2 |
1.0 | Flux-Cored | Fe | CO2 |
1.2 | Flux-Cored | Fe | CO2 |
0.8 | Flux-Cored | Fe | MIX |
0.9 | Flux-Cored | Fe | MIX |
1.0 | Flux-Cored | Fe | MIX |
1.2 | Flux-Cored | Fe | MIX |
1.0 | Solid | Al | Ar |
1.2 | Solid | Al | Ar |
Loading the Electrode Wire
Depending on the type of wire spool it can be installed on the wire spool support without adapter or installed with use applicable adapter that must be purchased separately (see “Accessories” chapter).
WARNING
Turn the input power OFF at the welding power source before installation or changing a wire spool.
- Turn the machine off.
- Open the side cover of the machine.
- Unscrew the locking nut of the sleeve.
- Load the spool with the wire on the sleeve such that the spool turns anticlockwise when the wire is fed into the wire feeder.
- Make sure that the spool locating pin goes into the fitting hole on the spool.
- Screw in the fastening cap of the sleeve.
- Put on the wire roll using the correct groove corresponding to the wire diameter.
- Free the end of the wire and cut off the bent end making sure it has no burr.
- The device is adapted to the spool max. 300mm
WARNING
Sharp end of the wire can hurt.
- Rotate the wire spool anticlockwise and thread the end of the wire into the wire feeder as far as the Euro socket.
- Adjust force of pressure roll of the wire feeder properly.
Adjustments of Brake Torque of Sleeve
To avoid spontaneous unrolling of the welding wire the sleeve is fitted with a
brake.
Adjustment is carried by rotation of its Allen screw M8, which is placed
inside of the sleeve frame after unscrewing the fastening cap of the sleeve.
- 31. Fastening cap.
- 32. Adjusting Allen screw M8.
- 33. Pressing spring.
Turning the Allen screw M8 anticlockwise increases the spring tension and you
can increase the brake torque Turning the Allen screw M8 clockwise decreases
the spring tension and you can decrease the brake torque.
After finishing of adjustment, you should screw in the fastening cap again.
Adjusting of Force of Pressure Roll Force
The pressure arm controls the amount of force the drive rolls exert on the
wire.
Pressure force is adjusted by turning the adjustment nut clockwise to increase
force, counterclockwise to decrease force. Proper adjustment of pressure arm
gives the best welding performance.
WARNING
If the roll pressure is too low the roll will slide on the wire. If the roll
pressure is set too high the wire may be deformed, which will cause feeding
problems in the welding gun. The pressure force should be set properly.
Decrease the pressure force slowly until the wire just begins to slide on the
drive roll and then increase the force slightly by turning of the adjustment
nut by one turn.
Inserting Electrode Wire into Welding Torch
- Turn the welding machine off.
- Depending on welding process, connect the proper gun to the euro socket, the rated parameters of the gun and of the welding machine should be matched.
- Remote the nozzle from the gun and contact tip or protection cap and contact tip. Next, straighten the gun out flat.
- Turn the welding machine on.
- Push the Cold Inch Switch [12] to feed the wire through the gun liner until the wire comes out of the threaded end.
- When switch is released spool of wire should not unwind.
- Adjust wire spool brake accordingly.
- Turn the welding machine off.
- Install a proper contact tip.
- Depending on the welding process and the type of the gun, install the nozzle (GMAW process) or protection cap (FCAW- process).
WARNING
Take precaution to keep eyes and hands away from the end of the gun while the
wire is being come out of the threated end.
Changing Driving Rolls
WARNING
Turn the input power off of the welding power source before installation or
changing drive rolls.
CITOLINE i250, CITOLINE i300 is equipped with drive roll V0.8/V1.0 for steel wire. For others wire type or / and diameter, the proper drive rolls kit you can find in ʺAccessoriesʺ chapter and follow instructions:
- Turn the input power OFF.
- Unlock 2 rolls by turning 2 Quick-Change Carrier Gear [38].
- Release the pressure roll levers [39].
- Change the drive rolls [37] corresponding to the used wire.
WARNING
Be sure that the gun liner and contact tip are also sized to match the
selected wire size.
WARNING
For wires with the diameter larger than 1.6mm, the following parts have to be
changed:
- The guide tube of the feeding console [35] and [36].
- The guide tube of the Euro Socket [34].
- Lock 2 new rolls by turning 2 Quick-Change Carrier Gear [38].
- Insert the wire through the guide tube, over the roller and through the guide tube of Euro Socket into liner of gun. The wire can be pushed into the liner manually for a few centimeters, and should feed easily and without any force.
- Lock the pressure roll lever [39].
Gas Connection
A gas cylinder must be installed with a proper flow regulator. Once a gas cylinder with a flow regulator has been securely installed, connect the gas hose from the regulator to the machine gas inlet connector.
WARNING
The welding machine supports all suitable shielding gases including carbon dioxide, argon and helium at a maximum pressure of 5,0 bars.
Transport & Lifting
WARNING
Falling equipment can cause injury and damage to unit.
During transportation and lifting with a crane, adhere to the following rules:
- Power source does not include the eye bolt which can be used to transport or lifting the machine.
- To lift use of suitable lifting equipment capacity.
- To lifting and transport use a travers and minimum two belts.
- Lift only power source without gas cylinder, cooler and wire feeder, or/and any other accessories.
Maintenance
WARNING
For any repair operations, modifications or maintenances, it is recommended to
contact the nearest Technical Service Center or Lincoln Electric. Repairs and
modifications performed by unauthorized service or personnel will cause, that
the manufacturer’s warranty will become null and void.
Any noticeable damage should be reported immediately and repaired.
Routine maintenance (everyday)
- Check condition of insulation and connections of the work leads and insulation of power lead. If any insulation damage exists replace the lead immediately.
- Remove the spatters from the welding gun nozzle. Spatters could interfere with the shielding gas flow to the arc.
- Check the welding gun condition: replace it, if necessary.
- Check condition and operation of the cooling fan. Keep clean its airflow slots.
Periodic maintenance (every 200 working hours but at list once every year)
- Perform the routine maintenance and, in addition:
- Keep the machine clean. Using a dry (and low pressure) airflow, remove the dust from the external case and from the cabinet inside.
- If it is required, clean and tighten all weld terminals.
The frequency of the maintenance operations may vary in accordance with the working environment where the machine is placed.
WARNING
Do not touch electrically live parts.
WARNING
Before the case of welding machine will be removed, the welding machine had to
be turned off and the power lead had to be disconnected from mains socket.
WARNING
Mains supply network must be disconnected from the machine before each
maintenance and service. After each repair, perform proper tests to ensure
safety.
Customer Assistance Policy
The business of The Lincoln Electric Company is manufacturing and selling high
quality welding equipment, consumables, and cutting equipment. Our challenge
is to meet the needs of our customers and to exceed their expectations. On
occasion, purchasers may ask Lincoln Electric for advice or information about
their use of our products. We respond to our customers based on the best
information in our possession at that time. Lincoln Electric is not in a
position to warrant or guarantee such advice, and assumes no liability, with
respect to such information or advice. We expressly disclaim any warranty of
any kind, including any warranty of fitness for any customer’s particular
purpose, with respect to such information or advice. As a matter of practical
consideration, we also cannot assume any responsibility for updating or
correcting any such information or advice once it has been given, nor does the
provision of information or advice create, expand or alter any warranty with
respect to the sale of our products Lincoln Electric is a responsive
manufacturer, but the selection and use of specific products sold by Lincoln
Electric is solely within the control of, and remains the sole responsibility
of the customer. Many variables beyond the control of Lincoln Electric affect
the results obtained in applying these types of fabrication methods and
service requirements.
Subject to Change – This information is accurate to the best of our knowledge
at the time of printing. Please refer to
www.oerlikon.com for any updated information.
WEEE
Do not dispose of electrical equipment together with normal waste! In
observance of European Directive 2012/19/EC on Waste Electrical and Electronic
Equipment (WEEE) and its implementation in accordance with national law,
electrical equipment that has reached the end of its life must be collected
separately and returned to an environmentally compatible recycling facility.
As the owner of the equipment, you should get information on approved
collection systems from our local representative.
By applying this European Directive you will protect the environment and human
health!
Spare Parts
Part List reading instructions
- Do not use this part list for a machine if its code number is not listed. Contact the Lincoln Electric Service Department for any code number not listed.
- Use the illustration of assembly page and the table below to determine where the part is located for your particular code machine.
- Use only the parts marked “X” in the column under the heading number called for in the assembly page (# indicate a change in this printing).
First, read the Part List reading instructions above, then refer to the “Spare Part” manual supplied with the machine that contains a picture-descriptive part number cross-reference.
REACh
Communication in accordance with Article 33.1 of Regulation (EC) No 1907/2006
– REACh.
Some parts inside this product contain:
Bisphenol A, BPAEC 201-245-8, , CAS 80-05-7
Cadmium,EC 231-152-8, CAS 7440-43-9
Lead,EC 231-100-4, CAS 7439-92-1
Phenol, 4-nonyl-, branched, EC 284-325-5, CAS 84852-15-3
in more than 0,1% w/w in homogeneous material. These substances are included
in the “Candidate List of Substances of Very High Concern for Authorisation”
of REACh.
Your particular product may contain one or more of the listed substances.
Instructions for safe use:
- use according to Manufacturer instructions, wash hands after use;
- keep out of reach of children, do not put in mouth,
- dispose in accordance with local regulations.
Authorized Service Shops Location
- The purchaser must contact Lincoln Electric or Authorized Service Facility about any defect claimed under warranty period.
- Contact your local Sales Representative for assistance in locating the nearest Authorized Service Facility.
Electrical Schematic
Refer to the “Spare Part” manual supplied with the machine.
Accessories
OPTIONS & ACCESSORIES
E/H-300A-50- x M| Electrode holder 300A/50mm², x =5 (5m) or x =10
(10m)
E/H-400A-70- x M| Electrode holder 400A/70mm², x =5 (5m) or x =10
(10m)
K10158-1| Adapter for spool type S300
K10158| Adapter for spool 300mm
R-1019-125-1/08R| Adapter for spool 200mm
Roll Kit For Solid Wires
KP69025-0608| SOLID DRIVE ROLL 0.6/0.8
KP69025-0809| SOLID DRIVE ROLL 0.8/0.9
KP69025-0810| SOLID DRIVE ROLL 0.8/1.0
KP69025-1012| SOLID DRIVE ROLL 1.0/1.2
KP69025-1216| SOLID DRIVE ROLL 1.2/1.6
Roll Kit For Aluminum Wires
KP69025-0608A| ALUMINUM DRIVE ROLL 0.6/0.8
KP69025-0809A| ALUMINUM DRIVE ROLL 0.8/0.9
KP69025-1012A| ALUMINUM DRIVE ROLL 1.0/1.2
KP69025-0810A| ALUMINUM DRIVE ROLL 0.8/1.0
KP69025-1216A| ALUMINUM DRIVE ROLL 1.2/1.6
Roll Kit For Cored Wires
KP69025-0608R| FLUX CORED DRIVE ROLL 0.6/0.8
KP69025-0809R| FLUX CORED DRIVE ROLL 0.8/0.9
KP69025-1012R| FLUX CORED DRIVE ROLL 1.0/1.2
KP69025-0810R| FLUX CORED DRIVE ROLL 0.8/1.0
KP69025-1216R| FLUX CORED DRIVE ROLL 1.2/1.6
MIG/MAG TORCHES
W10429-24-3M| LGS2 240 G-3.0M MIG GUN AIR COOLED
W10429-24-4M| LGS2 240 G-4.0M MIG GUN AIR COOLED
W10429-24-5M| LGS2 240 G-5.0M MIG GUN AIR COOLED
W10429-25-3M| LGS2 250 G-3.0M MIG GUN AIR COOLED
W10429-25-4M| LGS2 250 G-4.0M MIG GUN AIR COOLED
W10429-25-5M| LGS2 250 G-5.0M MIG GUN AIR COOLED
W10429-36-3M| LGS2 360 G-3.0M MIG GUN AIR COOLED
W10429-36-4M| LGS2 360 G-4.0M MIG GUN AIR COOLED
W10429-36-5M| LGS2 360 G-5.0M MIG GUN AIR COOLED
References
- Creating innovative industrial solutions for a better life | Oerlikon
- Operator Manuals, Spares and Wiring Diagrams | Lincoln Electric
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>