SAFETY INSTRUCTIONS

Important!

  • Carefully read the instructions before operating the unit
  • This appliance is for indoor use only.
  • Rating: This unit must be only connected to a 220 V / 15A earthed outlet.
  • Installation must be in accordance with the regulations of the country where the unit is used.
  • If you are in any doubt about the suitability of your electrical supply have it checked and, if necessary, modified by a qualified electrician.
  • This air conditioner has been tested and is safe to use. However, as with any electrical appliance – use it with care.
  • Disconnect the power plug from the socket before dismantling, assembling, or cleaning.
  • Avoid touching any moving parts of the appliance.
  • Never insert fingers, pencils, or any other objects through the guard
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities. It is also not intended for use by those with a lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Do not leave children unsupervised with this appliance.
  • Do not clean the unit by spraying it or immersing it in water.
  • Never connect the unit to an electrical outlet using an extension cord. If an outlet is not available, one should be installed by a qualified electrician.
  • Never operate this appliance if the cord or plug is damaged. Ensure the power cord is not stretched or exposed to sharp objects/edges.
  • A damaged supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard.
  • Any service other than a regular cleaning or filter replacement should be performed by an authorized service representative. Failure to comply could result in a voided warranty.
  • Do not use the appliance for any other purposes than its intended use.
  • The air conditioner unit must always be stored and transported upright, otherwise irreparable damage may be caused to the compressor; if in doubt we suggest waiting at least 24 hours before starting the unit.
  • Avoid restarting the air conditioning unit unless 3 minutes have passed since being turned off. This prevents damage to the compressor.
  • Never use the mains plug as a switch to start and turn off the air conditioning unit. Use the provided ON/OFF switch located on the control panel.
  • Always place the unit on a dry and stable surface.
  • The appliance should not be installed in the laundry or wet rooms
  • Do not use the appliance for any purpose other than those described in these instructions.
  • Minot will not accept any liability if the appliance is subject to improper use, or failure to comply with these instructions.
  • This machine is for household use only.
  • The appliance is for indoor use only, it’s not suitable for other occasions (including outdoor) use.

Energy Saving and Unit Safety Protection Tips

  • Do not cover or restrict the airflow from the outlet or inlet grills.
  • For maximum performance, the minimum distance from a wall or object should be 50cm.
  • Keep the filters clean. Under normal conditions, filters should only need cleaning once every three weeks (approximately). Since the filters remove airborne particles, more frequent cleaning may be necessary, depending on the air quality.
  • For the initial startup set the fan speed to maximum and the thermostat to 4-5 degrees lower than the current temperature. After, set the fan switch to low and set the thermostat to your desired setting.
  • To protect the unit we recommend not using the cooling function when the ambient temperature is higher than 35°C.

FEATURES AND PARTS LIST

  1. Features
    – Self-evaporative system
    – no external water tank is needed
    – Designer-inspired luxury model
    – LED screen, indicates the temperature and operation mode
    – On/Off timer function — allows you to choose when the unit operates
    – Compressor protection technology

  2. Parts list:

Winot MTA 12000C Portable Air Conditioner - Part list

  1. Exhaust pipe assembly
  2. Window sealing plate assembly
  3. Remote control
  4. Screw, washer, nut (for window kit)

INSTALLATION

Installation:
Warning: Before using this unit, please keep it upright for at least 3-4 hours. This unit can easily be moved from one room to another. While moving the unit please note that it must always be kept upright and then placed on an even surface.

  1. Assemble the fishtail connector onto the hose.

  2. Assemble the exhaust hose to the air conditioner body. Extend one head of the hose and screw it into the unit anti-clockwise. The hose can be removed by screwing the hose clockwise.
    Note: screw it into place should take no less than three rotations.

  3. In the same way, connect the hose to the assembled adaptor (at least three rotations).

  4. Installation of window kits.
    Partially open the window and then fix the window kit to the window.

  5. Make sure the unit is upright and there are no obstructions to the air inlets and outlet grills.

  6. Fix the other end of the hose to the air-outlet window kit.

Note: The window kit is only designed to be installed with sliding or sash windows or doors. The window kit is not designed or is to be used with any other style of window. However, the fishtail adaptor can be used with most windows/doors. When using the cooling mode ensure that the opening left is as small as possible. The best form of installation is through a wall duct. By properly venting, you expel hot air from your room while efficiently cooling it.

Important safeguards
The length of the soft hose extends from 28 cm to 150 cm. If the hose is extended above this length the unit may malfunction and this can invalidate the warranty. The outlet vent must be well-ventilated and not obstructed as this will cause the unit to overheat. Avoid bending the air hose more than 30 degrees It is recommended to use an original exhaust duct with a length of 150cm. If additional length is needed, we recommended to add one original exhaust duct only, total length is 300cm. Otherwise, if the length is too long, it will cause insufficient heat dissipation and result in failure. Warranty does not apply under improper use.

OPERATION AND SETTINGS

This portable air conditioner boasts 3 functions: cooling, dehumidifying, and fan. The fan has two speeds: high and low. Temperature range settings are 16-31°C. The unit will also display operating function, temperature, fault diagnostic, and protective functions on the LCD screen.

1. Control instruction Control panel

1: Swing button
2: Timer button
3: Speed button
4: Up button| 5: Down button
6: Mode button
7: Sleep button
8: Power button
---|---

When plugged in the unit is automatically in standby status.
The ‘POWER’ button presses the key to turn on and turn off the machine. In the case of power on, press the key to turn off the machine; in the case of power off, press the key to turn on the machine.
`MODE’ button In the case of power on, press the key to choose cooling, fan, and dehumidification mode.
`UP’ and ‘DOWN’ buttons: set temperature and timer.
In cooling mode, the temperature can range from 16— 31°C. The timer is 1-24 hrs.
Pressing the UP and DOWN buttons simultaneously, shifts between °C and °F.
‘FAN’ button
a) In cooling and fan mode, press the key to select high, medium, or low-speed operation.
b) In dehumidification mode, the fan key does not operate, and the fan will default to low-speed operation.
`TIMER’ button:
Press the button to select your desired operating times.
Use the and buttons to adjust hours from 1-24. You can only set the auto- shutoff timer while the unit is operating (on) You can only set the auto-start timer while the unit is switched off (standby) After you have set the timer will initiate and the units will start/ stop after the selected time. If you adjust the timer or press the power key previous settings will be cleared. Timer functions cannot be combined or repeated.
‘SWING’button: Press the button to turn on and turn off the swing function.

Sleep Mode: In the cooling Mode, Press the” Sleep buttons together to turn on the sleep mode, then the unit will work on Energy-Saving and lowest fan mode.
Note: The sleep mode is not operational in dehumidifying or Fan mode. Please use the remote control to set the sleep mode, it cannot be set from the air con touch control panel.

2. Operating Instructions of the Remote Control
2.1 Power: Press the key to turn on or off the machine
2.2 Mode: press the key to switch between cooling, fan, and dehumidification mode
2.3 Up press the + key to increase temperature and timer set value
2.4 Down: press the – key to reduce temperature and timer set value
2.5 Fan: press the key to cycle between high, medium, and low fan speed
2.6 Timer: press the key to set the timer value
2.7 Swing: Press the key to open or close the swing style. The airflow of the air outlet can blow at different angles.
2.8 Press the key to switch between Celsius and Fahrenheit
2.9 Sleep Mode: Press the key to turn on the sleep mode.

3. Multi-protective function
3.1. Frost Protection Function:
In cooling, dehumidification, or economic power saving mode, if the temperature of the exhaust pipe is too low, the machine will automatically enter protection status; if the temperature of the exhaust pipe rises to a certain temperature, it can automatically revert to normal operation.
3.2. Overflow Protection Function:
When the water in the water pan exceeds the warning level, the machine will automatically sound an alarm, and the LDC temperature display area will show “FL”. At this point, you need to move the drainage pipe connecting the machine or the water outlet to the sewer or another drainage area to empty the water (details see Drainage Instructions at the end of this chapter). After the water is emptied, the machine will automatically return to its original state.
3.3. Automatic Defrosting (heating and cooling models have this function):
The machine has an automatic defrosting function: during defrosting, a heating symbol on the display screen will flash.
3.4. Automatic Thermal Protection:
To protect the service life of the machine, the machine has automatic thermal protection in heating mode. During the protection period, the compressor and the blower motor will stop operation and will automatically return to a normal heating state after the temperature of the machine recovers.
3.5. Protection Function of the Compressor
To increase the service life of the compressor, it has a 3-minute delay booting protection function after the compressor is turned off.

WATER-DRAINAGE

  1. Manual drainage:
    1.1 When the internal water tank is full the unit will stop working.
    1.2 Shut off the unit and unplug. Try not to move the model abruptly as this may cause water to spill out from the internal water tank.
    1.3 Place a tray under the water plug.
    1.4 Screw off the drain plug and unplug the water rubber stopper – water will drain from the container.
    1.5 Put the water rubber stopper back and screw the drain
    1.6 Plug cap back into place

  2. Continuous drainage:
    2.1 Screw off the drain plug cap and unplug the water rubber stopper.
    2.2 Use a water pipe to connect to the water outlet.
    2.3 You can plumb this pipe into your current plumbing system, lead it outside or use a water pump.

Note: This model has a self-evaporative function, which reduces the need to empty the water tank. If the unit is vented correctly most of the water is reused to cool the condenser coils and any excess is evaporated. Please do not use continuous drainage if you intend to use the self-evaporating facility. If it is found that the water full light is on or there is water leakage, it is recommended to install the upper drain pipe first If the water leakage is still continued, you can install the lower drain pipe instead.

Maintenance

  1. Cleaning:
    Before cleaning and maintenance, turn off the machine and unplug the plug.
    Clean the surface
    Clean the surface of the machine with a wet soft cloth. Don’t use chemicals, such as benzene, alcohol, gasoline, etc.; otherwise, the surface of the air conditioning will be damaged or even the whole machine will be damaged.
    Air filter cleaning
    If the filter screen is clogged with dust, and the effectiveness of the air conditioning is reduced, be sure to clean the filter screen once every two weeks. A: Clean the upper filter screen frame
    a: Clasp the wedging block of the Evaporator filter screen frame with your hands. Force down from the outside to remove the Evaporator filter screen frame. and the rear housing to remove the Evaporator filter screen (as shown in the above figure).
    b: Put the Evaporator filter screen into warm water with neutral detergent (about 40 °C /104°F) and dry it in the shade after rinsing clean.
    B: Clean the lower filter screen frame
    a: Hold the handle of the air inlet filter screen frame, and pull it outward gently to remove it.
    b: Put the air inlet filter screen into warm water with neutral detergent (about 40°C / 104 °F) and dry it in the shade after rinsing clean.

  2. End of Season Maintenance:
    1. Pull out the plug from the drainage hole and empty the internal tank. You can also drain the water by leaning on the unit.
    2. Then switch the unit to low fan mode.
    3. Keep the unit in this mode for a half day – until the conduit is dried. Doing this helps to keep the inside of the unit dry and prevents mold from developing
    4. Turn off the unit and pull out the plug.
    5. Coil the wire and bind it together, then put it into the accessories space.
    6. Separate the air-exhaust pipe and store it safely.
    7. Cover the unit and keep it in a dry place.
    8. Take the batteries out of the remote control and store or dispose of, them safely Keep all accessories with the unit ready for next season.

  3. Emptying the condensate tank
    It is recommended to discharge the water inside the drain hole every month to keep the drain hole dry and clean, otherwise, it may lead to mechanical failure.

Troubleshooting

Do not repair or disassemble the air conditioning by yourself. The unqualified repair will lead to the failure of the warranty card and may cause damage to users or their properties.

P roblems Reasons Solutions
The air conditioning does not work. There is no electricity. Turn it on

after connecting it to a socket with electricity.
The overflow indicator displays “FL”.| Discharge the water inside.
The ambient temperature is too low or too high| Recommend to use the machine at the temperature of 7-35°C(44-95°F).
In cooling mode, the room temperature is lower than the set temperature; in heating mode, the room temperature is higher than the set temperature.| Change the set temperature.
In dehumidification mode, the ambient temperature is low.| The machine is placed in a room with an ambient temperature of greater than 17 °C. (62 °F).
The cooling or heating effect is not good| There is direct sunlight.| Pull the Curtain.
Doors or windows are open; there are a lot of people; or in cooling mode, there are other sources of heat.| Close doors and windows, and add new air conditioning.
The filter screen is dirty.| Clean or replace the filter screen.
The air inlet or outlet is blocked.| Clear obstructions.
Big Noise| The air conditioning is not placed on a flat surface.| Put the air conditioning in a flat and hard place (to reduce noise).
The compressor does not work.| Overheat protection starts.| Wait for 3 minutes until the temperature is lowered, and then restart the machine.
The remote control does not work.| The distance between the machine and the remote control is too far.| Let the remote control get close to the air conditioning, and make sure that the remote control directly faces the direction of the remote-control receiver.
The remote control is not aligned with the direction of the remote control receiver.
Batteries are dead.| Replace batteries.
Displays ‘El’.| The room temperature sensor is abnormal.| Check the room temperature sensor and related circuitry.
Displays ‘E2’| The pipe temperature sensor is abnormal.| Check the pipe temperature sensor and related circuitry.

If problems not listed in the table occur or recommended solutions do not work, please contact the professional service organization.

APPENDIX

Disposal:
Do not dispose of this product as unsorted municipal waste. Collection of such waste must be handled separately as special treatment is necessary. Recycling facilities are now available for all customers at which you can deposit your old electrical products. Customers will be able to take any old electrical equipment to participate in civic amenity sites run by their local councils. Please remember that this equipment will be further handled during the recycling process, so please be considerate when depositing your equipment. Please contact the local council for details of your local household waste recycling centers.

TECHNICAL DATA

Capacity: Cooling/Heating 3.52KWh/12,000BTU
Rated Input: Cooling/Heating 1340W
Air Flow 400m3/h
EER rate A
Compressor Rotary, R410A gas 530g
Anti-electric shock Rate I
Thermostat 16-31°C
Moisture removal 26.4L
Timer Yes
Remote control Yes
Net Weight 27Kg
Dimension(LDH) 420360722mm