PENTAIR Myers S4 Sump and Effluent Pumps Instruction Manual
- June 9, 2024
- Pentair
Table of Contents
PENTAIR Myers S4 Sump and Effluent Pumps
SAFETY PRECAUTIONS
All Myers sump pumps are grounded to prevent electrical shock. POWER CORD MUST
BE PLUGGED INTO GROUNDED TYPE RECEPTACLE. A separate circuit breaker or fuse
block should be used for the pump and 15 amp circuit breaker or fuse should be
used. Receptacle must be installed at least 4 feet above floor level to prevent
tampering by small children and to be out of possible flooding range. Be
careful with power cord to prevent cutting or pinching.
DO NOT USE AN EXTENSION CORD WITH SUMP PUMP. DO NOT CUT OFF GROUND PIN OR USE
AN ADAPTER FITTING. DO NOT WORK ON PUMP OR SWITCH UNTIL POWER CORD OR CORDS
ARE UNPLUGGED.
Sump basin must be vented in accordance with local plumbing codes. These pumps
are not designed for and cannot be installed in locations classified as
hazardous in accordance with the National Electric Code ANSI/NFPA 70.
CALIFORNIA PROPOSITION 65 WARNING:
This product and related accessories contain chemicals known to the State of
California to cause cancer, birth defects or other reproductive harm.
PUMP DESCRIPTION
The S4 is offered for either 115 volt or 230 volt–single phase–60 hertz. The
S4 sump pumps can be used to pump any basement drainage water. NOT TO BE USED
FOR SEWAGE WATER EXCEPT TO PUMP SEPTIC TANK EFFLUENT.
The S4 can be used to pump septic tank effluent but must be installed in
separate tank or compartment at the discharge side of the septic tank. NEVER
INSTALL PUMP DIRECTLY WHERE SLUDGE COLLECTS.
For septic tank pumping the automatic pumps should be used with a junction
box. The manual pumps should be used with a junction box and an MLC level
control. When a junction box is used, cut off the plugs on the pump cord and
the MLC switch cord and strip ends. The MLC switch must be connected in series
with one line. This provides a completely sealed system for power cord and
pump cord with no open receptacles or taped connections that can cause
electrical failure. The S4 sump pumps can be installed in any open or closed
type sump basin with a diameter of 12 to 18 inches. A polyethylene, fiberglass
or concrete tile basin may be used. If concrete tile is used, cement should be
poured in the bottom to give a smooth surface free of stones.
PIPING
Pumps can be installed with ABS, PVC, polyethylene, galvanized or copper pipe.
Proper adapters are required to connect plastic pipe to pump. The S4 discharge
is threaded for 1-1/2 inch pipe.
NOTE: DO NOT USE THREAD COMPOUND OR OVERTIGHTEN DISCHARGE PIPE INTO PUMP
PLASTIC DISCHARGE FITTING.
A CHECK VALVE MUST BE USED IN THE DISCHARGE LINE FOR ALL PUMPS. A shutoff
valve should be used with all S4 sump pumps. Always install check valve with
arrow on body in the direction of flow.
AIR LOCKING
A sump pump is said to be air locked if water traps air in the pump and the
air cannot get out, thus preventing pump from operating.
ALL MYERS SUMP PUMPS HAVE A SMALL AIR VENT HOLE IN THE IMPELLER CHAMBER TO LET
OUT TRAPPED AIR. IF THIS HOLE BECOMES PLUGGED, PUMP MAY AIR LOCK. THIS USUALLY
HAPPENS ON PUMPS THAT ARE USED MAINLY IN THE WET SEASONS. IN SUMMER MONTHS,
THE PUMP MAY BE TURNED OFF AS SUMP WATER DRIES UP. WHEN PUMP IS TURNED ON
AGAIN AND WATER COMES UP IN SUMP, THE AIR WILL TRAP IN PUMP IF NOT VENTED. AS
A SECONDARY PRECAUTION IN INSTALLATIONS OF THIS TYPE – 1/8″ HOLE SHOULD BE
DRILLED IN THE DISCHARGE PIPE BELOW THE CHECK VALVE. THE CHECK VALVE SHOULD BE
12 TO 18 INCHES ABOVE PUMP DISCHARGE. DO NOT PUT CHECK VALVE DIRECTLY INTO
PUMP DISCHARGE OPENING.
STARTING PUMP – S4A (AUTOMATIC)
- These pumps have an integral mechanical ball float switch as shown on installation drawing.
- The S4A1C is for 115 volts and S4A2C is for 230 volts. Plug cord into the proper voltage GROUNDED RECEPTACLE. The 115 volt plug will not plug into a 230 volt receptacle and vice versa.
- Run water into sump until pump starts.
- Allow pump to operate through several on-off cycles to be sure operation is satisfactory.
- If shutoff valve is used in discharge line, be sure valve is open.
NOTE: TETHER LENGTH OF SWITCH CORD MUST BE A MINIMUM OF 3-5/8″.
STARTING PUMP – S4M (MANUAL) USING MFS SWITCH WITH SERIES PLUG
- Install unit as shown on the installation drawing. Secure ball float to discharge pipe with minimum 3- 1/2 inches between float and cable tie.
- The S4M1C is for 115 volts and the S4M2C is for 230 volts. Plug MFS switch cord series plug into proper voltage GROUNDED RECEPTACLE.
- Plug pump cord plug into back of switch cord series plug.
- Run water into sump until pump starts. The level should be 12 to 13 inches above sump bottom.
- Be sure gate valve in discharge line is open.
NOTE: TETHER LENGTH OF SWITCH CORD MUST BE A MINIMUM OF 3-5/8″.
USING THE S4M FOR MANUAL OPERATION
The pump cord for these units can be plugged directly into proper GROUNDED
RECEPTACLE for continuous pump operation.
CAUTION: THIS TYPE OF OPERATION SHOULD BE USED ONLY FOR EMERGENCY USE OR
WHERE A LARGE VOLUME OF WATER IS TO BE PUMPED, SUCH AS A FLOODED BASEMENT.
PUMP MUST NOT RUN CONTINUOUSLY OUT OF WATER. DO NOT USE WITH EXTENSION CORD.
AUTOMATIC/MANUAL MODEL
The model S4 sump pumps can be changed from one style, automatic or manual, to
the other by only interchanging the plug ends of the float control with the
manual plug. The ball floats must be tethered with a cable clamp, as shown. DO
NOT REMOVE THE MOTOR CAP.
HOW MECHANICAL SWITCH FLOAT OPERATES
This level control uses a mechanical switch sealed in a polypropylene float
cylinder. The switch is not position sensitive; that is, it will operate
regardless of position. When level rises in the sump, the cylinder floats up
with the level. When the cylinder position is at an angle of about 45°, the
steel ball rolls over a detent and activates the switch. This starts the pump
motor. As the sump level draws down, the cylinder floats down and when it is
again at an angle of about 45°, the steel ball drops away, deactivating the
switch and the motor stops.
BE SURE CYLINDER FLOATS FREELY IN SUMP BASIN WITHOUT TOUCHING THE BASIN WALLS.
ADJUST PUMP POSITION IN SUMP IF NECESSARY.
PUMP MOTOR
NEVER REMOVE MOTOR HOUSING OR UNSCREW PUMP IMPELLER. Warranty on pump is void
if motor housing, impeller or seal have been removed. Any repair on motor must
be done by an authorized Myers service center.
CLEANING FLOAT
If pump becomes inoperative because of accumulation of trash on the float,
remove pump from sump and clean float.
- Wipe all water and dirt from pump and float.
- Be sure float operates freely after cleaning.
CLEANING IMPELLER AND VOLUTE CASE
- Remove the 5 screws that hold the lower plastic base to the plastic volute case.
- Use screwdriver to separate the plastic parts. Use care not to gouge a groove in the plastic. Pry in several spots to loosen.
- Remove loosened part and clean impeller and volute passage.
- Be sure impeller turns freely after cleaning.
- Clean out holes in plastic pump base and wash thoroughly before replacing.
- DO NOT UNSCREW IMPELLER.
TROUBLESHOOTING
Item | Cord Length | Volt | Part Number |
---|---|---|---|
Control Switch | 10′ | 115 | 218139130 |
20′ | 115 | 218139131 | |
10′ | 230 | 218139132 | |
20′ | 230 | 218139133 | |
10′ | 115 | 216289041 | |
20′ | 115 | 216289044 | |
10′ | 230 | 216289042 | |
20′ | 230 | 216289043 |
REPAIR PARTS
**Ref. No.**
| **Description| ****Qty.| Part Numbers
---|---|---|---
S4A1C| S4A2C| S4M1C| S4M2C**
1| Cord, Electric, with Plug| 1| 21628B044| 21628B043| 21628B044| 21628B043
2| Control, Level, with Plug Connector| 1| 21813B128| 21813B128| –| –
3| Plug, 1/8″ Pipe| 1| 05022A068| 05022A068| 05022A068| 05022A068
4| Wire with Terminals| 1| 09859A800| 09859A800| 09859A800| 09859A800
5| Screw, Machine 1/4-20 x 7/8 Lg.| 6| 18475A003| 18475A003| 18475A003|
18475A003
6| Cap, Motor (Not Stamped)| 1| 24431C000| 24431C000| 24431C000| 24431C000
7| Ring, O, 5-1/2 x 5-1/4 I.D. x 1/8| 1| 05876A146| 05876A146| 05876A146|
05876A146
8| Oil, Transformer (1 gal. in can)| .375 gal.| 11009A008| 11009A008|
11009A008| 11009A008
9| Housing & Stator Assembly Includes:| 1| 24446C010| 24446C011| 24446C010|
24446C011
Housing| 1| 24446C001| 24446C001| 24446C001| 24446C001
Stator| 1| 21599B020| 21599B021| 21599B020| 21599B021
Washer, SST, 1 x 33/64 x 1/32| 2| 05030A173| 05030A173| 05030A173| 05030A173
Washer, Teflon®, 1 x 33/64 x 1/16| 1| 05030A163| 05030A163| 05030A163|
05030A163
Rotor with Shaft| 1| 22821A001| 22821A001| 22821A001| 22821A001
Plate, Bearing| 1| 24661B000| 24661B000| 24661B000| 24661B000
10| Screw, S-T, #10 x 1/2 Lg.| 2| 09822A006| 09822A006| –| –
11| Clam, Cable| 1| 17190A008| 17190A008| –| –
12| Seal, 1/2″ Shaft| 1| 21607A010| 21607A010| 21607A010| 21607A010
13| Screw, Mach., Flat HD., #10-24 x 5/8″| 4| 07597A030| 07597A030| 07597A030|
07597A030
14| Impeller| 1| 21542B000| 21542B000| 21542B000| 21542B000
15| Sealant, Loctite® Grade 222| 1| 14550A005| 14550A005| 14550A005| 14550A005
16| Case, Volute| 1| 24633D000| 24633D000| 24633D000| 24633D000
17| Base| 1| 21543D000| 21543D000| 21543D000| 21543D000
18| Clip| 4| 21609A000| 21609A000| 21609A000| 21609A000
19| Screw, S-T, #10 x 1-3/4″| 5| 09822A040| 09822A040| 09822A040| 09822A040
20| Plate| 1| 21544B000| 21544B000| 21544B000| 21544B000
21| Plug, Manual| 1| –| –| 24448A000| 24448A000
22| Washer, Plastic| 1| –| –| 05030A213| 05030A213
23| Plug, Connector| 1| –| –| 24449A000| 24449A000
S4A TYPICAL INSTALLATION
S4M TYPICAL INSTALLATION
STANDARD LIMITED WARRANTY
Pentair Myers® warrants its products against defects in material and workmanship for a period of 12 months from the date of shipment from Pentair Myers or 18 months from the manufacturing date, whichever occurs first – provided that such products are used in compliance with the requirements of the Pentair Myers catalog and technical manuals for use in pumping raw sewage, municipal wastewater or similar, abrasive-free, noncorrosive liquids. During the warranty period and subject to the conditions set forth, Pentair Myers, at its discretion, will repair or replace to the original user, the parts that prove defective in materials and workmanship. Pentair Myers reserves the right to change or improve its products or any portions thereof without being obligated to provide such a change or improvement for prior sold and/or shipped units. Start-up reports and electrical schematics may be required to support warranty claims. Submit at the time of start- up through the Pentair Myers website: http://forms.pentairliterature.com/startupform/startupform.asp?type=m. Warranty is effective only if Pentair Myers authorized control panels are used. All seal fail and heat sensing devices must be hooked up, functional and monitored or this warranty will be void. Pentair Myers will cover only the lower seal and labor thereof for all dual seal pumps. Under no circumstance will Pentair Myers be responsible for the cost of field labor, travel expenses, rented equipment, removal/reinstallation costs or freight expenses to and from the factory or an authorized Pentair Myers service facility. This limited warranty will not apply: (a) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with the printed instructions provided; (b) to failures resulting from abuse, accident or negligence; (c) to normal maintenance services and parts used in connection with such service; (d) to units that are not installed in accordance with applicable local codes, ordinances and good trade practices; (e) if the unit is moved from its original installation location; (f) if unit is used for purposes other than for what it is designed and manufactured; (g) to any unit that has been repaired or altered by anyone other than Pentair Myers or an authorized Pentair Myers service provider; (h) to any unit that has been repaired using non factory specified/OEM parts.
Warranty Exclusions: PENTAIR MYERS MAKES NO EXPRESS OR IMPLIED WARRANTIES THAT EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. PENTAIR MYERS SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR ANY PARTICULAR PURPOSE.
Liability Limitation: IN NO EVENT SHALL PENTAIR MYERS BE LIABLE OR
RESPONSIBLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES RESULTING FROM OR
RELATED IN ANY MANNER TO ANY PENTAIR MYERS PRODUCT OR PARTS THEREOF. PERSONAL
INJURY AND/OR PROPERTY DAMAGE MAY RESULT FROM IMPROPER INSTALLATION. PENTAIR
MYERS DISCLAIMS ALL LIABILITY, INCLUDING LIABILITY UNDER THIS WARRANTY, FOR
IMPROPER INSTALLATION. PENTAIR MYERS RECOMMENDS INSTALLATION BY PROFESSIONALS.
Some states do not permit some or all of the above warranty limitations or the
exclusion or limitation of incidental or consequential damages and therefore
such limitations may not apply to you. No warranties or representations at any
time made by any representatives of Pentair Myers shall vary or expand the
provision hereof.
1101 MYERS PARKWAY ASHLAND, OHIO, USA 44805
419-289-1144
WWW.FEMYERS.COM
Warranty Rev. 12/13
490 PINEBUSH ROAD, UNIT #4
CAMBRIDGE, ONTARIO, CANADA N1T 0A5 800-363-PUMP