poly 1354-68669-001 RealPresence Group Series Media Center Installation Guide

June 9, 2024
Poly

1354-68669-001 Real Presence Group Series Media Center
Installation Guide

1354-68669-001 Real Presence Group Series Media Center

Polycom Real Presence Group Series Media Center with 65 Inch Dual Displays

This supplement describes how to attach 65 inch dual displays on the Polycom Real Presence Group Series Media Center. Follow the instructions in Setting Up the Polycom  Real Presence Group Series Media Center, 1725-08510-00X, and use this supplement to replace the steps to install the displays.
Single 55/65 inch Lower Display Rail, 1354-67626-002poly 1354 68669 001
RealPresence Group Series Media Center - fig(2) Dual 65 inch Lower Display Rail Extension, 1354-68667-002poly 1354 68669 001 RealPresence Group Series Media Center -
fig1Dual 65 inch Center Top Display Rail, 1354-68669-001poly 1354 68669 001 RealPresence Group Series
Media Center - fig2(2) Dual 65 inch Upper Display Rail Extension, 1354-68671-001poly 1354 68669 001 RealPresence Group Series Media Center -
fig3

(4) Display Mounting Bracket Assembly  2342-67629-001
(4) M8 x 20 Button Head Cap Screw 1601-52713-001
(4) M8 Hex Flange Nut 1600-52845-001
(4) M10 x 25 Flanged Socket Head Cap Screw
1601-67617-002
M8 Wrench
1102-68064-001

For more information about the components of the Real Presence Group Series Media Center, refer to the documentation at http://support.polycom.com/PolycomService/support/us/support/video/group_series/group_packaged_solutions.html.

The Media Center components are heavy. Polycom recommends that two people perform the installation.

5a Install the lower display rail by aligning the holes in the display rail with the holes in the vertical supports. Attach with four M10 x 25 flanged socket head cap screws. Do not  fully tighten.

poly 1354 68669 001 RealPresence Group Series Media Center -
fig4

5b Install a lower display rail extension to each side of the lower display rail using two M8 x 20 button head cap screws and two M8 hex nuts per side. Ensure the edge of the rail  extension is 3.97 inches from the inner cut edge of the bottom display rail. Tighten using the supplied M8 wrench.poly
1354 68669 001 RealPresence Group Series Media Center -
fig5

6a Attach an upper display rail extension to each end of the center top display rail using two M10 x 25 flanged socket head cap screws per extension. poly 1354 68669 001 RealPresence Group Series Media Center -
fig6

6b Install the upper display rail assembly by aligning the holes in the display rail with the holes in the vertical supports. Attach with two M10 x 25 flanged socket head cap screws per vertical support. Do not fully tighten.poly 1354 68669 001 RealPresence Group Series Media Center -
fig7

Attach the rear panel by inserting the two tabs at the bottom of the door into the slots in the base. This serves as an alignment tool to ensure the frame is properly aligned  before tightening all bolts. Using the L-key, tighten the socket head cap screws at the bottom of the base, the lower display rail, and the upper display rail. Remove the rear panel.poly 1354 68669 001
RealPresence Group Series Media Center - fig8

On the back side, install a handle on both ends of the bottom display rail.poly 1354 68669 001 RealPresence Group Series Media Center -
fig9

Install the display mount brackets on the display. For the LG and Sampo 65 inch (PMQ65ML) display, position the display mounting bracket using the sixth hole from the top  with the top mounting hole on the display. The bottom hole on the display is the seventh hole up from the bottom of the bracket.
For the Sampo 55 inch and 65 inch (PME65MA) display, position the third hole down from the top of the display bracket with the third hole down from the top of the  display. The bottom hole on the display lines up with the fifth hole up from the bottom of the display bracket.
Install the supplied 1/4-20 x 3.5 inch socket head cap screws at the top of each display bracket. Leave the screws adjusted up before mounting the display to the top rail.
Repeat with the second display.

LG 65 inch and Sampo 65 (PMQ65ML) inch Displaypoly 1354 68669 001
RealPresence Group Series Media Center - fig10

Sampo 55 inch and 65 inch (PME65MA) Display poly 1354 68669 001
RealPresence Group Series Media Center - fig11

With the assistance of another person, lift the display and position the display bracket hooks above the edge of the upper horizontal display rail on the Media Center.  Carefully lower the display onto the rail, ensuring the hooks are fully engaged with the rail and that the outer most bracket is positioned within the safety tab on the outer rail  end (1). Repeat with the second display.
Adjust the leveler screws as needed to help eliminate any gap between the two displays when they are tightly abutted (2).poly 1354 68669 001 RealPresence
Group Series Media Center - fig12

Center the displays on the Media Center. Insert one M6 x 16 flanged button head screw into each outer display bracket to lock the displays.poly 1354
68669 001 RealPresence Group Series Media Center - fig13

Power Rating:
Voltage rating: 100-240 VAC, 50/60Hz
Maximum power consumption (configured with Group Series 500 codec and EagleEye IV camera under full load operating conditions):
651.4W with Sampo (PME65MA) display
591.4W with Sampo (PMQ65ML) display
651.4W with LG display
Approximate system weight (including displays, codec, camera, and sound system):
715 lbs. with Sampo (PME65MA) display
613 lbs. with Sampo (PMQ65ML) display
555 lbs. with LG display

Regulatory Notices:

  • This equipment is intended for indoor use only.
  • Only use this equipment with the displays supplied by Polycom.
  • Do not use a power cord that is damaged. This could cause fire or electric shock. Contact the manufacturer for a replacement cord, if necessary.
  • Only use a power cord which is appropriately rated and approved relevant to the country of use.
  • This equipment should be used only on even surfaces.
  • When moving or positioning the system, only use the handles located at the bottom of the display rail at the rear of the unit.
  • This equipment has lockable wheels which should be applied while the cart is stationary.
  • When connecting to the mains supply, connect only to an earthed supply outlet which is installed near the equipment and is easily accessible.
  • Keep ventilation openings free from any obstructions.
  • The ambient operating temperature rating of this equipment is 0 – 40ºC and should not be exceeded.
  •  Do not immerse the system in any liquid or place any liquids on it.
  • Do not spray liquids directly onto the system when cleaning. Always apply the liquid first to a static-free cloth.
  • For further information concerning the individual components of this equipment, please refer to the respective product literature.
  • For support or service, please contact your Poly distributor or go to the Poly Online Support Center at support.polycom.com/content/support.html.

© 2021 Plantronics, Inc. All rights reserved.
Poly, the propeller design, and the Poly logo are trademarks of Plantronics, Inc.
The Bluetooth trademark is owned by Bluetooth SIG,
Inc. and any use of the mark by Plantronics, Inc. is under license.
All other trademarks are the property of their respective owners.
1725-68117-003A

Documents / Resources

| poly 1354-68669-001 RealPresence Group Series Media Center [pdf] Installation Guide
1354-68669-001 RealPresence Group Series Media Center, 1354-68669-001, RealPresence Group Series Media Center, Media Center
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals