SKOPE SCS Connect Electronic Controller
Service Procedures
Exchanging a Refrigeration Unit
Open SCS Connect Track App and perform a manual scan on the designated cabinet
before isolating it from the mains power supply. For manual scan instructions
see “Track App” on page 13.
Follow all instructions documented in the appropriate Service Manual to ensure
the exchange of the refrigeration unit is completed correctly.
Once the replacement refrigeration unit has been installed and tested, and is
operating correctly, tell the customer that this cabinet is ready to be set up
via the SKOPE-connect App.
If the customer is a Corporate customer see “SCS Setup” on page 10.
Swapping a Faulty Controller
Open SCS Connect Track App and perform a manual scan on the cabinet before
isolating it from the mains power supply. For manual scan instructions see
“Track App” on page 13.
Follow all instructions documented in the appropriate Service Manual to ensure
the safe removal and replacement of the faulty controller. Return the faulty
controller to SKOPE for analysis.
You will need to use the Field App to download the correct parameters file
from the cloud, as replacement controllers are not supplied with SKOPE
parameters.
Once the replacement controller has been installed and tested, and is
operating correctly, tell the customer that this cabinet is ready to be set up
via the SKOPE-connect App.
If the customer is a Corporate customer see “SCS Setup” on page 10.
Application Procedures
Open the required app on your smart device. The app must be installed before opening.
SCS Connect Field App
For SCS Connect Field app installation, see Quick Start Guide PRN80176.
SCS Connect Track App
For SCS Connect Track app installation, see Quick Start Guide PRN80177.
Field App
Home Screen The home screen gives you a live snapshot of the cabinet’s
operation, components and any alarms or events.
Note: Only inputs connected to, or components directly controlled by, the SCS Connect controller will be displayed upon the Home Screen. For example, if the condenser fan is directly driven from the compressor then the condenser fan icon will not be displayed on the home screen.
Events (Alarms or Faults) can be accessed directly from the home screen.
This allows you to view details about the fault, as well as history of the
recorded faults.
Tap on any component showing the small yellow triangle symbol to view the
current event.
From the details screen you can see the possible cause, along with a current
reading and any parameters that may be related to the fault.
The event history for that component can be viewed by selecting the yellow
triangle beside Event History.
App Menu The menu (three horizontal bars on the top right hand side)
provides access to the first level of the app’s functions.
App menu items
Menu item | Description |
---|---|
Home | Returns to the home screen |
Output control | Output control screen |
Edit parameters | Access the parameters for editing |
Load parameter file | Select a parameters file from local or cloud storage |
Statistics | Review the controller’s statistics |
SCS info | Details of the SCS controller |
SCS setup | Set up and change asset information |
Disconnect | Disconnect the app from the controller |
Settings | App settings |
IMPORTANT After any controller connection or modification has been completed, always DISCONNECT your device from the controller to confirm all changes.
Output Control Displays real time data when connected to the cabinet by allowing real time interaction with both inputs (probes, switches) and outputs (relays, PWM).
Note: Any selected output changes override any priorities in the
controller, but are limited to a 2-minute time scale before resetting to their
previous status.
You can add or remove inputs or outputs via the + button. This will add or
remove a trace line from the live chart.
Only relays that are being used can be switched.
If the fan motor is a controlled speed motor, operating speeds are shown.
The negative number shows counterclockwise rotation.
CAUTION
Do NOT switch the compressor on and off without allowing pressure to equalise
in between. Switching on and off may cause permanent damage to the compressor
leading to failure.
Edit Parameters
Parameters are arranged in categories to help with navigation. Drop-down boxes
give lists of available parameters – scroll up and down for the complete list.
Only parameters needed to operate the cabinet will be visible. These may
differ between cabinet types.
Each category contains the parameters associated with that mode.
Note: If you change a parameter you must note details of all changes on
all warranty or service documentation, including the original setting, the new
setting and reasons why the change was made. Updates are not applied until
DISCONNECT has been selected from menu.
To change a parameter, select the parameter and making the adjustment using
the slider or the – and + buttons. Save the using the Enter button within the
newly opened screen. The maximum and minimum allowances for each parameter are
shown, along with a Default button.
IMPORTANT
Do NOT press the Default button.
The Default button sets the parameter back to Wellington Drive defaults, not
SKOPE defaults.
When a parameter is selected, a new screen opens allowing you to modify the
parameter.
Load Parameters
When you are installing a new controller, or trying to diagnose a fault and
there is a chance that the parameters may have been corrupted or modified, the
Field App allows you to download the SKOPE factory parameters files stored in
the cloud.
Selecting Load Parameter File opens the Select Configuration File page which
shows the status of the currently selected file and gives the option of
selecting a new file. Press Select File.
From this screen you can access the parameters file from either Server (the
cloud) or Local (your device). You must only use released parameters files.
To ensure that you have the most recent parameters file SKOPE recommends you always download the latest release from the cloud. A data connection is required. If no data connection is available, download the correct parameters file, using the Download button, to your device (Local) before to travelling to the site. Once downloaded, select Local to check that you have the correct file.
From the Local list choose the required file to upload to the SCS controller.
Check the “Current File” field to ensure the correct parameters file has been
selected, then press Write to SCS.
To delete a file from your device, select the parameters file from the list
and press Delete.
Note: New parameters updates are not applied until DISCONNECT has been
selected from the menu.
Statistics The statistics section allows you to view the last 7 days’
data from within the SCS Connect controller.
To see the data better, turn your device into landscape mode (on its side).
You can add data points to review multiple points at once. Seeing operational
trends or intermittent faults may help to diagnose problems.
Press the + button, then select the data points you wish to add to your chart.
SCS Info
The SCS Info section contains information about the controller, including the
firmware versions and key data about the cabinet:
- SKOPE Asset #
- SKOPE Serial # (the asset and serials numbers will be the same in most instances)
- Model of the cabinet
- Brand of the cabinet – the brand will vary if the cabinet belongs to a Corporate customer
If your role includes setting up cabinets for Corporate or Fleet customers, you may have access to Reset IDs (see “Reset Cabinet IDs” on page 12 for further details).
SCS Setup
Corporate only.
Note: General Market cabinets require the cabinet to be set up via the
SKOPE-connect app, which the store owner or manager will have access to. Check
to see if they have it on their device.
SCS Setup is only available in certain roles. If your role requires regular
access to this procedure and you do not have access, contact SKOPE.
Linking an SCS controller to a refrigeration cabinet is a key part of allowing
accurate data to be gathered for review and service assistance.
Select the appropriate owner and the brand.
The cabinet owner should always be set to SKOPE – this should come pre-set
from the factory. The brand is the corporate customer who is using the
cabinet. This is not set at the factory before delivery and must be set before
placing the cabinet into the market.
IMPORTANT
Always select SKOPE as the cabinet owner from the drop-down box if not already
set.
The list of available brands will appear once the cabinet owner has been set.
Ensure you select the correct brand at this stage as an additional reset
process will be required if it is set incorrectly.
When the owner and brand are successfully set, you can add the key details of
the cabinet.
There are 6 sections in the SCS Setup page. The first 4 must be completed; the
corporate owner may require all 6 to be completed.
Asset # may be either the Corporate Asset # or the SKOPE Serial #. You can
enter this manually
(Corporate #), or use the camera on your device to scan the bar-code on the
serial label inside the cabinet (SKOPE #).
Cabinet Model: Selectable drop-down box once the Asset # has been entered.
This can be checked against the serial label inside the cabinet.
Manufacturer Serial #: Can be added by pressing the Edit button and using the
camera on your device to scan the bar-code on the serial label inside the
cabinet (the same process as for the Asset #).
Install Address: Manually type in the physical address of the location
for the installed cabinet.
Select Show on Map to see the actual location. If the shown Google Address is
correct, press the Use Google Address button. This is recommended, as it
ensures a consistent address format.
Select the Outlet/Unit tab, enter any available data and press the Save
button.
Additional Data: If the corporate owner permits access via the SKOPE-
connect app, then the Customer ID field must remain blank. If the corporate
owner wishes to restrict this access, the SKOPE-connect access can be
deactivated. See “Deactivate SKOPE-connect” on page 11.
Information stored in the Customer ID field may be hidden from view.
Photo and Notes: Optional. This may be required by the corporate owner.
If these need tobe added, take an picture of the store from the outside, as
well as one of the entire cabinet once installed. These photos will be found
in the photos app on your device and can be added one at a time. SKOPE
recommends one for cabinet and one for the store.
IMPORTANT
Photos can’t be removed once saved. Choose appropriate photos, as they will be
visible to all people who have access to the reporting application.
Use the Notes for both the Cabinet and the Outlet for relevant information to
help identify location of the cabinet, or things that may affect its
performance or operation.
After information has been entered, disconnect from the controller to use the
Track App to capture all relevant data.
Deactivate SKOPE connect
You will only need to enter information in this tab if the corporate owner
does not permit access to the cabinet via the SKOPE-connect application that
the store owner may have. If the corporate owner wishes to restrict this
access, you need to add a Customer ID.
IMPORTANT
The customer ID field must be blank if SKOPE-connect access is required.
Reset Cabinet IDs
Corporate only.
General Market cabinets do not require an ID reset. Follow this process to
change the brand attributed to a cabinet after it has initially been set.
Open the SCS Info section from the menu. If you have the required level of
access you will see the option to Reset IDs. Resetting the IDs will clear all
manufacturer and owner information, and you will need to re-enter it.
After a successful ID Reset you will need to follow the SCS Setup process
which will include an additional step to enter the Manufacturer information.
Select the Menu.
The Menu screen will differ from normal. Select SCS Setup from the list.
IMPORTANT
You must select SKOPE from the drop-down list.
Once you have successfully set the manufacturer, you can continue the process of setting up brand and asset information. See “SCS Setup” on page 10.
Track App
Bluetooth must be on to perform a manual scan with the Track App. Open the App
and press the Scan or Connect Now button.
Data from the cabinet will be downloaded into your device and then uploaded to
the cloud for future analysis.
Note: “Download completed” does not mean that the data has been uploaded
to the cloud. The upload process requires data, and will be automatically
completed when data coverage available.
Alarms
Display
Any alarms that happen can result in warm product, and are logged. Some alarms
can be cleared by the store owner, but others can only be cleared by a service
technician.
Alarm Codes
Display | Alarm Type | Description |
---|---|---|
dor | Door open | The door has been open for several minutes. |
ALr2 ALr3 | Over voltage protection Under voltage protection | The maximum or |
minimum allowable mains supply voltage has been exceeded. The cabinet has
temporarily shut down to prevent damage and will restart once the supply
voltage decreases or increases.
ALr8| Estimated product temperature below allowable range| The estimated
product temperature has been below the allowable range for longer than the
permissible time.
Potential causes include an empty or partially filled cabinet, low ambient temperature.
ALr9| Estimated product temperature above allowable range| The estimated product temperature has been above the allowable range for longer than the permissible time.
Potential causes include excessive door openings, door being left open, warm product loaded into cabinet.
ALr14| High condensing temperature protection| The system was operating at an elevated temperature and has temporarily shut down to prevent damage. Extended operation in this condition may result in increased energy consumption and a reduction in cabinet life.
This alarm may be caused by very high ambient temperature.
ALr15| Excessive condensing temperature protection| The system was operating
at an excessive temperature and has shut down to prevent permanent damage.
This alarm may occur due to very high ambient temperature.
ALr17| Control probe failure| A critical system sensor has failed, and the
cabinet can no longer operate.
ALr18| Electrical over-current protection activated| The compressor was
drawing too much current and has shut down to prevent permanent damage.
ALr19| Failed to reach set temperature| The refrigeration system has been
operating continuously for a long period without reaching the set temperature.
ALr20| Over-cooling product| The internal temperature is too low. The system
has temporarily shut down until the temperature has returned to normal.
This alarm may be caused by the set temperature being raised by a large amount.
ALr21| Excessive compressor cycling protection| The system has been turning on
and off too frequently.
ALr22| Evaporator fan over-current protection| The current supplied to the
evaporator fan motor is too high.
ALr23| Condenser fan over-current protection| The current supplied to the
condenser fan motor is too high.
ALr24| Controller communication error| The controller has lost communication
channels.
ALr25| Controller update failure| The controller update could not be
completed.
ALr26| Controller hardware failure| The controller hardware has failed.
ALr27| Probe failure| A non-critical system probe has failed. The cabinet will
continue to operate with partial function but requires service.
ALr28| No downward tendency| The temperature is no longer decreasing.
ALr29| Compressor cutting out| The compressor cut out on its internal
protection or a pressure switch.
ALr30| Excessive automatic defrosting| The system is automatically defrosting
too frequently.
ALr31| Compressor stall| The compressor is stalling on start up.
CUSTOMER SERVICE
SCS Connect Electronic Controller
Technicians’ Manual
MAN80199
Rev. 1.1 Jan. 2022
© 2019 SKOPE Industries Limited. All rights reserved.
SKOPE Industries Limited reserves the right to alter specifications without
notice.
is a registered trademark of SKOPE Industries Limited.
SKOPE Industries Limited
ABN: 73 374 418 306
AU: 1800 121 535
NZ: 0800 947 5673
skope@skope.com
www.skope.com
SKOPE INDUSTRIES LIMITED
Head Office
PO Box 1091, Christchurch
New Zealand
A.B.N. 73 374 418 306
AU: 1800 121 535
NZ: 0800 947 5673
E-mail: skope@skope.com
Website: www.skope.com
Trademark Infringement
The SKOPE trademark on this product is infringed if the owner, for the time
being, does any of the following:
-
Applies the trade mark to the product after its state, condition, get-up or packaging has been altered in any manner
-
Alters, removes (including part removal) or obliterates (including part obliteration) the trade mark on the product
-
Applies any other trade mark to the product
-
Adds to the product any written material that is likely to damage the reputation of the trade mark
Notice of the above contractual obligations passes to: -
Successors or assignees of the buyer
-
Future owners of the product