Midea D50-15ED2 Storage Electric Water Heater Instruction Manual
- June 9, 2024
- Midea
Table of Contents
Midea D50-15ED2 Storage Electric Water Heater
CAUTIONS
Before installing this water heater ,check and confirm that the earthing on
the supply socket is reliably grounded. Otherwise, the electrical water heater
can not be installed and used. Do not use extension boards. Incorrect
installation and use of this electrical water heater may result in serious
injuries and loss of property.
Special Cautions
- The supply socket must be earthed reliably. The rated current of the socket shall not be lower than 10A. The socket and plug shall be kept dry to prevent electrical leakage.
- The installation height of the supply socket shall not be lower than 1.8m.
- The wall in which the electrical water heater is installed shall be able to bear the load more than two times of the heater filled fully with water without distortion and cracks. Otherwise, other strengthen-ing measures shall be adopted.
- The pressure relief valve attached with the heater must be installed at the cold water inlet of this heater(see Fig.1), and make sure it is not exposed in the foggy. The water may be outflowed from pressure relief valve, so the outflow pipe must open wide in the air; The pressure relief valve need to be checked and cleaned regularly, so as to make sure it will not be blocked.
-
When using the heater for the first time(or the first use after maintenance), the heater can not be switched on until it has been filled fully with water. When filling the water, at least one of the outlet valves at the outlet of the heater must be opened to exhaust the air. This valve can be closed after the heater has been filled fully with water.
-
The water heater is not intended for use by persons(including children)with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instructions concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the heater.
-
During heating, there may be drops of water dripping from the pressure release hole of the pressure relief valve. This is a normal phenomenon. If there is a large amount of water leak, please contact customer care center for repair. This pressure release hole shall, under no circumstances, be blocked; otherwise, the heater may be damaged, even resulting in accidents.
-
The drainage pipe connected to the pressure release hole must be kept sloping downwards. Since the water temperature inside the heater can reach up to 75℃, the hot water must not be exposed to human bodies when it is initially used. Adjust the water temperature to a suitable temperature to avoid scalding.
-
If the flexible power supply cord is damaged, the special supply cord provided by the manufacturer must be selected, and replaced by the professional maintenance personnel. If any parts and components of this electrical water heater are damaged please contact customer care center for repair.
-
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
-
Children should be supervised to ensure that they do not play with the appliance.
The maximum inlet water pressure is 0.5MPa; the minimum inlet water pressure is 0.1MPa, if this is necessary for the correct operation of the appliance. -
The water may drip from the discharge pipe of the pressure-relief device and that this pipe must be left open to the atmosphere; The pressure-relief device is to be operated regularly to remove lime deposits and to verify that it is not blocked.
-
In order to drain away the water inside the inner container, it can be drained away from the pressure release valve. Twist the thread screw of the pressure release valve off, and lift the drain handle upwards.(See Fig.1) A discharge pipe connected to the pressure-relief device is to be installed in a continuously downward direction and in a frost-free environment.
PRODUCT INTRODUCTION
Nomenclature
- is the product code of the storage electric water heater; is the capacity (L);
- represents the rated power (*100W);
- represents the pattern code (eg : A,B,C…);
- represents the extension of pattern (eg : 1,2,3…);
NOTE: This manual is applicable to the storage electric water heaters (D *-***) manufactured by this company.
Technical Performance Parameters
Model
| Volume (L)| Rated Power (W)| Rated Voltage (ACV)| Rated Pressure (MPa)| Max
Of Water Temperature (°C)| Protection Class| Waterproof Grade
---|---|---|---|---|---|---|---
D30-15ED2| 28| 1500| 220-240| 0.8| 75| I| IPX4
D50-15ED2| 47| 1500| 220-240| 0.8| 75| I| IPX4
D80-15ED2| 74| 1500| 220-240| 0.8| 75| I| IPX4
D100-15ED2| 93| 1500| 220-240| 0.8| 75| I| IPX4
Brief introduction of product structure
| D30-20ED2| D50-20ED2| D80-20ED2| D100-20ED2
---|---|---|---|---
A| 470| 470| 570| 570
B| 575| 860| 900| 1090
C| 250| 250| 300| 300
D| 355| 355| 415| 415
E| 183| 183| 265| 265
F| 302| 470| 365| 550
(Note: All dimensions are in mm)
Internal Wire Diagram
UNIT INSTALLATION
Installation Instruction
-
This electrical water heater shall be installed on a solid wall. If the strength of the wall cannot bear the load equal to two times of the total weight of the heater filled fully with water, it is then necessary to install a special support.
Incase of hollow bricks wall, ensure to fill it with cement concrete completely. -
After selecting a proper location, determine the positions of the two install holes used for expansion bolts with hook, Make two holes in the wall with the corresponding depth by using a chopping bit with the size matching the expansion bolts attached with the machine, insert the screws, make the hook upwards, tighten the nuts to fix firmly, and then hang the electrical water heater on it (see Fig.2).
-
Install the supply socket in the wall. The requirements for the socket are as follows: 250V/10A, single phase, three electrodes. It is recommended to placed the socket on the right above the heater. The height of the socket to the ground shall not be less than 1.8m (see Fig.3).If there is fault on power cable, it should be replaced by the manufacturers, agencies or qualified person who is able to do this so as to ensure the safety.
-
If the bathroom is too small, the heater can be installed at another place. However, in order to reduce the pipeline heat losses, the installation position of the heater shall be closed to the location shall be as near as possible to the heater.
Pipelines Connection
- The dimension of each pipe part is G1/2” ; The massive pressure of inlet should use Pa as the unit; The minimum pressure of inlet should use Pa as the unit.
- Connection of pressure relief valve with the heater on the inlet of the water heater.
- In order to avoid leakage when connecting the pipelines, the rubber seal gaskets provided with the heater must be added at the end of the threads to ensure leak proof joints (see Fig.4).
- If the users want to realize a multi-way supply system, refer to the method shown in fig.5 and fig.6 for connection of the pipelines.
NOTE
Please be sure to use the accessories provided by our company to install this
electric water heater. This electric water heater can not be hung on the
support until it has been confirmed to be firm and reliable. Otherwise, the
electric water heater may drop off from the wall, resulting in damage of the
heater, even serious accidents of injury. When determining the locations of
the bolt holes, it shall be ensured that there is a clearance not less than
0.2m on the right side of the electric heater, to convenient the maintenance
of the heater, if necessary.
METHODS OF USING
- First, open any one of the outlet valves at the outlet of the water heater, then, open the inlet valve. The water heater gets filled with water. When water flows out of the outlet pipe it implies that the heater has been filled fully with water, and the outlet valve can be closed.
NOTE: During normal operation, the inlet valve shall be always kept open.
- Insert the supply plug into the supply socket, the indicator will light up this time.
- The thermostat will automatically control the temperature. When the water temperature inside the heater has reached the set temperature, it will switch off automatically, when the water tempera-ture falls below the set point the heater will be turned on automatically to restore the heating.
Operating Of The Unit
(Fig.7)
- “1” button is for selecting mode. When press firstly, display screen “4” will show the six frequency option( index number “1” means 1500W for one tank, index number “2” means 1500W for dual tank , index number “3” means smart control energy saving mode, index number “4” means ECO mode, index number “5” means high temperature bacteriostatic mode, index number “6” means reservation hour setting mode).
- “2” is the on/off button, when press, water heater start working, display screen will be lighted up. Then press again, electricity will be cut off, and display screen will be shut down.
- “3” is for temperature adjustment knob with 360 °loop. Temperature increases by clockwise rotation, and decreases if anticlockwise. During the rotation , display screen ” 4″ will change accordingly. When temperature setting meets customers’ requirements, stop rotating and display screen “4” will flash for around 3 seconds, which means temperature has been settled successfully. After flashing ,display screen “4” value will return to current inner water heater temperature. After the smart control energy saving mode, the knob can not be adjusted.
- “6” is for frequency display. If number ” 1″ comes out , it means 1500W(only one tank is heating ) ; If number “2” comes out , it means 1500W (the two inner tank has been being heated up ), If number ” 3″ comes out , it means smart control energy saving mode, the water temperature is automatically changed. The appliance works to reduce the electricity energy of the user consumption, which allows heat loss to be minimized and energy savings to be maximized. This function is manually activated. The user can press the POWER button three times to start the smart control.
- From “5” &“7” &“8”(this horizontal strip ) , customer could tell heating status and WIFI connection status . The light “5” will turn on when power is connected. The light “5“ will blink , when smart control energy saving mode is started , According the temperature settled, the light “7” will be shown in red which means water heater is being heated. When inner water heater temperature reaches the settled value , light “7” will turns off , which means water heater enter into warm-keeping status. Long press the on key for 3 seconds, and the WIFI light starts to flash. After the connection is completed, the WIFI light is always on.
- “4” could show the current inner water temperature as well as settled temperature value. If no person operates on water heater , the value in display screen ” 4″ means current temperature value .By spinning knob “3” , “4” values will vary accordingly ( i.e temperature setting process) , when finish temperature setting , “4” values will return back to actual current inner water heater temperature.
Error code for serviceman’s use
- E2: Dry Asking—Top up with water and re-heat.
- E3: Overheating—Check the heating system or replace it. E4: Sensor Fault—Check the sensor or replace it.
MAINTENANCE
- Temperature limiter cut off electricity if water heater is overheated or thermostat damages. Manual resetting is needed. Resetting knob is as follows (see Fig.9).
WARNING
Non-professionals are not allowed to disassemble temperature limiter to
reset . Please contact professionals to maintain. Otherwise our company will
not take responsibility if any quality accident happens because of this
- Check the power supply plug and socket frequently to make sure that they have good, reliable contact and are well grounded without overheating phenomenon.
- If the heater is not used for a long time, especially in the regions with low atmospheric temperature(lower than 0℃), the water inside the heater shall be drained away. This will prevent the damage to the heater due to water freezing in the inner container, (Refer Cautions in this manual for the method to drain away the water from the inner container).
- In order to ensure that the water heater operates efficiently for a long time, it is recommended to clean the inner container and the deposits on the electrical heating components periodically.
- It is recommended to examine the magnesium anode protection materials every six months or so. If all the material has been consumed, please replace with the new material.
WARNING
Do cut off power supply before maintenance, to avoid danger like electric
shock.
TROUBLESHOOTING
NOTE
This products are not equipped with plug. Please contact professionals to
purchase and install plug. Parts illustrated in this use and care manual are
indicative only, parts provided with the product may differ with
illustrations. This product is intended for household use only. Specifications
are subject to change without notice.
Produce information with EU regulation
The electrical storage water heater D50-15ED2 of the company MIDEA Ltd. was
tested with a declared load profile of the size “M”
The product fulfills and corresponds to the requirements of the commission
regulation standards (No 814/2013) for electrical storage water heater and
achieved a water heating energy efficiency of ηwh=39% that correspond to the
water heating efficiency class “B”
In accordance with AnnexⅡ Energy Efficiency Classes article 1 of the
commission regulation (No 812/2013)
The evaluation of the result of this report with respect of conformity with
the related commission regulation (No 812/2013 and 814/2019) is only a part of
the conformity assessment to achieve the ErP-Label. Electricity consumption
Qelec, water heating energy efficiency ηwh and mixed water at 40°C (V40).
Description | Parameter | Value | Unit |
---|---|---|---|
k-Value | k | 0.23 | |
Smart control compliance | smart | 1 | |
Smart control factor | SCF | 23.2 | % |
Conversion coefficient | CC | 2.5 | |
Ambient correction term | Qcor | -0.082 | |
Referent energy | Qref | 5.845 | kWh |
Useful energy content | QH2O | 5.958 | kWh |
Correction ratio of reference and useful energy | Qref/QH2O | 0.981 | kWh |
Daily electricity consumption (measured) | Qtest_elec | 7.423 | kWh |
Water temperature at the beginning of the 24h measurement cycle | T3 | 73.9 | ℃ |
Water temperature at the end of the 24h measurement cycle | T5 | 71.4 | ℃ |
Storage volume | Mact | 47 | kg |
Storage volume | Cact | 47 | L |
Daily electricity consumption (corrected) | Qelec | 7.417 | kWh |
Sequence of SMART tapping cycles used during the test | M/S/M/S/M |
Useful energy content of the hot water drawn-off during smart period Qreference,H2O expressed in kWh:|
Qreference,H2O
|
22.161
| kWh
Useful energy content of the hot water drawn-off during smart period
Qsmart,H2O expressed in kWh:|
Qsmart,H2O
|
22.157
| kWh
The weekly electricity consumption with smart controls| Qelec, week, smart|
26.662| kWh
The weekly electricity consumption without smart controls| Qelec, week|
29.288| kWh
Water heating energy efficiency| ηwh| 39.2| %
Annual Electricity Consumption| AEC| 1309| kWh
Water heating energy efficiency class| B
Water temperature without tapping| Tset| 73| ℃
Average water temperature of inlet cold water| θc| 10.4| ℃
Normalized value of the average temperature| θp| 72.6| ℃
Calculated volume that delivered hot water of at least 40℃| V40| 75| L
The electrical storage water heater D80-15ED2 of the company MIDEA Ltd. was
tested with a declared load profile of the size “M”
The product fulfills and corresponds to the requirements of the commission
regulation standards (No 814/2013) for electrical storage water heater and
achieved a water heating energy efficiency of ηwh=39% that correspond to the
water heating efficiency class “B”
In accordance with AnnexⅡ Energy Efficiency Classes article 1 of the
commission regulation (No 812/2013)
The evaluation of the result of this report with respect of conformity with
the related commission regulation (No 812/2013 and 814/2019) is only a part of
the conformity assessment to achieve the ErP-Label. Electricity consumption
Qelec, water heating energy efficiency ηwh and mixed water at 40°C (V40).
Description | Parameter | Value | Unit |
---|---|---|---|
k-Value | k | 0.23 | |
Smart control compliance | smart | 1 | |
Smart control factor | SCF | 21.5 | % |
Conversion coefficient | CC | 2.5 | |
Ambient correction term | Qcor | -0.107 | |
Referenct energy | Qref | 5.845 | kWh |
Useful energy content | QH2O | 5.958 | kWh |
Correction ratio of reference and useful energy | Qref/QH2O | 0.981 | kWh |
Daily electricity consumption (measured) | Qtest_elec | 7.803 | kWh |
Water temperature at the beginning of the 24h measurement cycle | T3 | 74 | ℃ |
Water temperature at the end of the 24h measurement cycle | T5 | 71.9 | ℃ |
Storage volume | Mact | 74 | kg |
Storage volume | Cact | 74 | L |
Daily electricity consumption (corrected) | Qelec | 7.781 | kWh |
Sequence of SMART tapping cycles used during the test | M/S/M/S/M |
Useful energy content of the hot water drawn-off during smart period Qreference,H2O expressed in kWh:| Qreference,H2O|
22.157
| kWh
Useful energy content of the hot water drawn-off during smart period
Qsmart,H2O expressed in kWh:|
Qsmart,H2O
|
22.156
| kWh
The weekly electricity consumption with smart controls| Qelec,week,smart|
28.364| kWh
The weekly electricity consumption without smart controls| Qelec,week| 31.426|
kWh
Water heating energy efficiency| ηwh| 39.0| %
Annual Electricity Consumption| AEC| 1315| kWh
Water heating energy efficiency class| B
Water temperature without tapping| Tset| 73| ℃
Average water temperature of inlet cold water| θc| 10.4| ℃
Normalised value of the average temperature| θp| 72.6| ℃
Calculated volume that delivered hot water of at least 40℃| V40| 110| L
The electrical storage water heater D100-15ED2 of the company MIDEA Ltd. was
tested with a declared load profile of the size “M”
The product fulfills and corresponds to the requirements of the commission
regulation standards (No 814/2013) for electrical storage water heater and
achieved a water heating energy efficiency of ηwh=41% that correspond to the
water heating efficiency class “B”
In accordance with AnnexⅡ Enercy Efficiency Classes article 1 of the
commission regulation (No 812/2013)
The evaluation of the result of this report with respect of conformity with
the related commission regulation (No 812/2013 and 814/2019) is only a part of
the conformity assessment to achieve the ErP-Label.
Electricity consumption Qelec, water heating energy efficiency ηwh and mixed
water at 40°C (V40).
Description | Parameter | Value | Unit |
---|---|---|---|
k-Value | k | 0.23 | |
Smart control compliance | smart | 1 | |
Smart control factor | SCF | 15.82 | % |
Conversion coefficient | CC | 2.5 | |
Ambient correction term | Qcor | -0.02278 | |
Referenct energy | Qref | 5.845 | kWh |
Useful energy content | QH2O | 5.958 | kWh |
Correction ratio of reference and useful energy | Qref/QH2O | 0.981 | kWh |
Daily electricity consumption (measured) | Qtest_elec | 6.5851 | kWh |
Water temperature at the beginning of the 24h measurement cycle | T3 | 73.3 | ℃ |
Water temperature at the end of the 24h measurement cycle | T5 | 72.8 | ℃ |
Storage volume | Mact | 92 | kg |
Storage volume | Cact | 92.1 | L |
Daily electricity consumption (corrected) | Qelec | 6.765 | kWh |
Sequence of SMART tapping cycles used during the test | M/S/M/S/M |
Useful energy content of the hot water drawn-off during smart period Qreference,H2O expressed in kWh:| Qreference,H2O|
22.127
| kWh
Useful energy content of the hot water drawn-off during smart period
Qsmart,H2O expressed in kWh:| Qsmart,H2O|
22.100
|
kWh
The weekly electricity consumption with smart controls| Qelec,week,smart|
25.529| kWh
The weekly electricity consumption without smart controls| Qelec,week| 27.832|
kWh
Water heating energy efficiency| ηwh| 40.8| %
Annual Electricity Consumption| AEC| 1258| kWh
Water heating energy efficiency class| B
Water temperature without tapping| Tset| 73| ℃
Average water temperature of inlet cold water| θc| 10.4| ℃
Normalised value of the average temperature| θp| 68.2| ℃
Calculated volume that delivered hot water of at least 40℃| V40| 131| L
The product is subject to change without notice. Please keep this manual properly.
References
- Midea Italia | Climatizzazione residenziale e multisplit, frigoriferi, lavatrici, elettrodomestici e piccoli elettrodomestici per la casa
- Midea - Make yourself at Home - World's Number 1 Appliance Producer
Read User Manual Online (PDF format)