CTM SC-1200 series 1200W Pure Sine Wave Inverter / Charger Instruction Manual
- June 9, 2024
- CTM
Table of Contents
CTM SC-1200 series 1200W Pure Sine Wave Inverter / Charger
Feature
-
Bi-directional All-in-One Design
-
Compact Size
Highly Integration = Installation hassle-free -
Certifed by UL
UL458 & Supplement SA / CSA C22.2 No. 107.1-01
UL1741 / CSA C22.2 No. 107.1-01 / KKK-A-1822F (For Ambulance) -
5-in-1 Operating Modes
1. Inverter mode 2. Charger mode 3. Power Sharing 4. Power Generation
5. Power Support
| | SC-1200-112| SC-1200-124| SC-1200-212| SC-1200-224
---|---|---|---|---|---
Inverter Mode| | | | |
Input| Nominal Voltage| 12 VDC| 24 VDC| 12 VDC| 24 VDC
| Input Voltage Range (±0.5V)| Input Voltage Range (±0.5V)| 21.0 ~ 33.0 VDC|
10.5 ~ 16.5 VDC| 21.0 ~ 33.0 VDC
| Input Over-Voltage Protection (±0.5V)| 16.5 VDC| 33.0 VDC| 16.5 VDC| 33.0
VDC
| Input Over-Voltage Warning (±0.5V)| 15.5 VDC| 31.0 VDC| 15.5 VDC| 31.0 VDC
| Input Under-Voltage Protection (±0.5V)| 10.5 VDC| 21.0 VDC| 10.5 VDC| 21.0
VDC
| Input Current (Max)| 132 A| 66 A| 132 A| 66 A
| No Load Current| < 3.0 A @12.5V| < 1.5 A @25V| < 3.0 A @12.5V| < 1.5 A @25V
| Stand-By Current| < 0.4 A| < 0.2 A| < 0.4 A| < 0.2 A
Output| Continuous Output Power| 1200 VA ± 3%
| Surge Power| Load 101%~115% (1 Min) / 2400 VA (2 Sec)
| Frequency| 50/60 Hz ± 0.3 Hz (User-selectable)| | |
| Output Voltage| 100 / 110 / 115 / 120VAC ±3%| | 200 / 220 / 230 / 240VAC ±3%
| Max. E‑ciency (Full Load)| 89%| 90%| 89%| 90%
| Output Waveform| Pure Sine Wave (THD < 5% @ 12.5V/25V/115VAC, linear load) /
(THD < 3% @ 12.5V/25V/230VAC, linear load)
| INV. AC Output| 12A MAX| | 6A MAX|
| AC Output| 30A MAX| | 22A MAX|
Protection| Input Protection| Over / Under Voltage, Reverse Polarity (Internal
Fuse)
| AC Output Protection| Short-Circuit, Overload
| AC Input Protection| 30 Amp Circuit Breaker| | 16 Amp Circuit Breaker|
| Battery Temperature protection| By a RJ-11 connector to battery Temperature
sensor
Charger Mode
AC input| Nominal Voltage / Frequency| 110 VAC, 50 / 60Hz (User-selectable)| |
230 VAC, 50 / 60Hz (User-selectable)
| Input Voltage Range| 90 ~ 132 VAC| | 180 ~ 264 VAC
| Input Frequency Range| 50Hz:47 ~ 53 Hz / 60Hz:57 ~ 63 Hz
| Nominal Current| 8.2A (@110VAC)| | 3.9A (@230VAC)
| E‑ciency (Max.)| >88%
| AC Input| 30 A MAX| | 16 A MAX|
| Power Factor Correction (PFC)| >0.95 (Max.)
Auxiliary DC Output| Output Voltage| Battery Voltage
| Output Current| 20A Max
DC Output| Charging Current Range| 12.5 / 25 / 37.5 / 50A| 6.25 / 12.5 / 18.75
/ 25A| 12.5 / 25 / 37.5 / 50A| 6.25 / 12.5 / 18.75 / 25A
| Max. Output Voltage| 14.4 VDC@ GEL TYPE| 28.8 VDC @ GEL TYPE| 14.4 VDC @ GEL
TYPE| 28.8 VDC @ GEL TYPE
| Battery Temperature Compensation| -25 mV per ℃| -50 mV per ℃| -25 mV per ℃|
-50 mV per ℃
| Battery Control (3-stage Battery Chargers)| Bulk / Absorption / Float| | |
Signal and Control| Remote Control Panel (Optional)| CR-20C / CR-16B / CR-8| |
|
| Dry Contact Terminal| By a relay| | |
| Relay Specication| 30 Amp / 120 VAC @ 110V system| 16 Amp / 250 VAC @ 230V
system
Environment| | | | |
Operating Temperature| Full Load| -20 ℃ ~ 50 ℃| | |
Range| Power de-rating| 40 W / ℃, 51~60 ℃| | |
| Storage| 30 ℃~70 ℃| | |
Operating Humidity Range| | Max 93%, Non-condensing| | |
Cooling| | Temperature & Load Controlled Cooling Fan| | |
Safety Standards| | UL458 & Supplement SA / UL1741| | EN 62368-1|
E-mark| | | | Certied CISPR 25; ISO7637-2|
EMC Standards| | | | EN55032 Class A, EN55024 Class A EN61000-3-2, 3-3 ,
EN61000-4-2, 3, 4, 5, 6, 8, 11|
Other| | | | |
Dimension (W x H x D)| | 251 x 116 x 386mm| | |
Net Weight| | 4.55Kg| | |
Max Inverter output define inverter 100% load output at Vac =100V / 200V
Max AC output define AC input current + Inverter output current, cannot over AC input limit.
Max AC input current Limit by the Breaker
For SC-1200 -112 and -124, the operating temperature range certified by UL Safety Standard is -20°C ~ 40°C.
*SC series is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures
The Battery Charger
Front panel
Ⓐ AC Output
Ⓑ AC Input
Ⓒ Chassis ground
Ⓓ Main switch
Ⓔ DIP switch
Ⓕ Function LED
Ⓖ AC input breaker
Ⓗ AC Output terminal (L/N)
Ⓘ AC Input terminal (L/N)
Ⓙ AC In/Output ground terminal
Function LED
BAT : Display input voltage
LED Status | DC12V | DC24V |
---|---|---|
Red | < 11.0V | < 22.0V |
Orange | 11.0 ~ 11.5V | 22.0 ~ 23.0V |
Green | 11.5 ~ 15.0V | 23.0 ~ 30.0V |
Orange | 15.0 ~ 15.5V | 30.0 ~ 31.0V |
Red | >15.5V | >31.0V |
Load: Display AC loads (PF=1)
LED Status | SC-1200 / SC-2000 |
---|---|
Red | > 115% |
Orange | 100 ~ 115% |
Green | 0 ~ 100 % |
Dark | Charger Mode |
Status : Display System Status
LED Status | Status |
---|---|
Green | Normal |
Green Slow Blink | OTP |
Green Fast Blink | UTP |
Orange | PLL/Frequency Fail |
Orange Slow Blink | AC in UVP/OVP |
Orange Fast Blink | AC IN OCP |
Red | OLP / SCP |
Red Slow Blink | Battery UVP |
Red Fast Blink | Battery OVP |
Charger : Display Charger Stage
LED Status | SC-1200 / SC-2000 |
---|---|
Orange Blink | Bulk |
Orange | Absorption |
Green | Float |
Red | Charger Error |
Green Fast Blink | Active |
Green Slow Blink | Equalization |
Dark | Inverter Mode |
The Battery Charger
Mechanical Drawings
Dip switch Function
Dip Switch | Function |
---|---|
S1 | **** |
Output Voltage Select
S2
S3| Frequency Select
S4| ****
AC Input Current Limit Select
S5
S6
S7| ****
Battery Type Select
S8
S9| ****
Charger Current Select
S10
S11| DC Source on/off
S12| Saving Function on/off
AC Input Current Limit Select (S4,S5,S6)
AC Input Current
100~120V / 200~240V
| S4| S5| S6
---|---|---|---
3A / 2A| OFF| OFF| OFF
6A / 4A| ON| OFF| OFF
9A / 6A| OFF| ON| OFF
12A / 8A| ON| ON| OFF
15A / 10A| OFF| OFF| ON
20A / 12A| ON| OFF| ON
25A / 14A| OFF| ON| ON
30A / 16A| ON| ON| ON
Charger Current Select Function (S9,S10)
Charger Current | S9 | S10 |
---|---|---|
25% | OFF | OFF |
50% | ON | OFF |
75% | OFF | ON |
100% | ON | ON |
Saving Function Switch ON/OFF Function (S12)
Saving function | S12 |
---|---|
OFF | OFF |
ON | ON |
Output Voltage switch Function (S1,S2)
Output Voltage | S1 | S2 |
---|---|---|
100V / 200V | OFF | OFF |
110V / 220V | ON | OFF |
115V / 230V | OFF | ON |
120V / 240V | ON | ON |
Output Frequency switch Function (S3)
Frequency | S3 |
---|---|
50HZ | OFF |
60HZ | ON |
Battery Type Select Function (S7,S8):
Battery Type | S7 | S8 |
---|---|---|
GEL | OFF | OFF |
Flooded | ON | OFF |
AGM | OFF | ON |
Customer | ON | ON |
Battery Type | Bulk | Absorption |
--- | --- | --- |
GEL | 14.40V | 14.10V |
Flooded | 14.70V | 14.60V |
AGM | 14.70V | 14.30V |
Customer | 14.70V | 14.50V |
DC Source Output On/Off Function (S11)
ESB function | S11 |
---|---|
OFF | OFF |
ON | ON |
Power Saving Load Function
SC series -212, -224 | Default: 40VA |
---|---|
Entering the saving power | Load<32VA |
Wake up the saving power | Load>40VA |
SC series -112, -124 | Default: 20VA |
--- | --- |
Entering the saving power | Load<16VA |
Wake up the saving power | Load>20VA |
Rear panel
BAT. TEMP. Port (RJ-11) \
Pin Number | Signal Description |
---|---|
1 | Not used |
2 | GND |
3 | Batteries temperature sensor |
4 | Battery Detect |
5 | Not used |
6 | Not used |
Remote Port (RJ-11)
Pin Number | Signal Description |
---|---|
1 | Reserved |
2 | GND |
3 | RXD |
4 | TXD |
5 | RMT |
6 | VCC |
Remote Control & Green Terminal
Remote control green terminal may be connected to a Form C relay for “FAULT” indication. When “FAULT” occurs, the relay switches.
Remote control terminal
Item | Description | Item | Description |
---|---|---|---|
1 | Dry contact (Normal Open) | 4 | Enable+ (ENB) |
2 | Common | 5 | Enable- (ENB) |
3 | Dry contact (Normal Closed) | 6 | Ground |
Dry contact terminal definition
Specifications of the Relay
Maximum Voltage|
Load
| Contact Rating| Number of operations| Operating/Storage
Temperature
---|---|---|---|---
N.O| N.C
250 VAC| Resistive| 1 A| —| 100,000|
-30℃~75℃
250 VAC| Resistive| —| 1 A| —
24 VDC| Resistive| 1 A| —| —
24 VDC| Resistive| —| 1 A| —
Documents / Resources
| CTM
SC-1200 series 1200W Pure Sine Wave Inverter /
Charger
[pdf] Instruction Manual
SC-1200 series 1200W Pure Sine Wave Inverter Charger, SC-1200 series, 1200W
Pure Sine Wave Inverter Charger, Wave Inverter Charger, Inverter Charger
---|---
References
Read User Manual Online (PDF format)