Bestway 58391 Hmax 1.5m Filter Pump Owner’s Manual
- June 9, 2024
- Bestway
Table of Contents
Bestway 58391 Hmax 1.5m Filter Pump
58391
©2022 Bestway Inflatables & Material Corp.
All rights reserved
Trademarks used in some countries under license from Bestway Central & South
America Ltda, Salar Ascotan 1282, Parque Enea, Pudahuel, Santiago, Chile
Distributed in Australia & New Zealand by Bestway Australia Pty Ltd, Unit
2/98-104 Carnarvon St Silverwater, NSW 2128, Australia
Tel: Australia: (+61) 2 9037 1388; New Zealand: 0800 142 101
Distributed in United Kingdom by Bestway Corp UK Ltd. 8 Wentworth Road,
Heathfield Industrial Estate, Newton Abbot, Devon, TQ12 6TL Exported by
Bestway (Hong Kong) International Ltd./Bestway Enterprise Company Limited
Suite 713, 7/Floor, East Wing, Tsim Sha Tsui Centre, 66 Mody Road, Kowloon,
Hong Kong
www.bestwaycorp.com
Instruction
WARNING
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
WARNING – RISK OF ELECTRIC SHOCK – The pump is to be supplied by an isolating
transformer or supplied through a residual current device (RCD) having a rated
residual operating current not exceeding 30 mA.
The power source on the wall of building should keep more than 4m away from
pool.
The appliance must be supplied by earthed power source. Extension cords can’t
be used.
DO NOT BURY CORD. Locate cord to minimize abuse from lawn mowers, hedge
trimmers, and other equipment.
WARNING – If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in order to
avoid a hazard.
CAUTION – This pump is for use with storable pools only. Do not use with
permanently-installed pools. A storable pool is constructed so that it is
capable of being readily disassembled for storage and reassembled to its
original integrity. A permanently-installed pool is constructed in or on the
ground or in a building such that it cannot be readily disassembled for
storage.
IMPORTANT – Using the pump with an unmatched electrical supply is
dangerous and will result in catastrophic failure of pump. RISK OF
ELECTRICAL SHOCK – When working with electricity, turn the electrical
power off at the circuit breaker and lock breaker door. Failure to do so will
result in increased risk of shock, injury and possibly death.
DO NOT REMOVE THE GROUNDING PRONG OR MODIFY THE PLUG IN ANY WAY. DO NOT USE
ADAPTOR PLUGS. Consult a qualified electrician for any questions related to
the validity of your plugs grounding.
Handle the pump with care. Do not pull or carry the pump by the power cord.
Never pull a plug from the outlet by yanking the power cord. Keep cord free
from abrasions. Sharp objects, oil, moving parts, and heat should never be
exposed to the filter pump. WARNING – This appliance can be used by children
aged from 8 years and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a safe way
and understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by children without
supervision. Cleaning and user maintenance must be performed by an adult above
18 years old who is familiar with the risk of electric shock. When the
appliance will be not used for a long time, such as in the winter, the pool
set should be disassembled and stored indoor. CAUTION – Read the instruction
before using the appliance and installation/reassembly every time.
The appliance must be placed more than 2m away from the pool. Electric
installations should follow national wiring rules. Consult a qualified
electrician for any questions.
Only the media provided or specified by the manufacturer is to be used with
product installation.
It is essential to check that the suction openings are not obstructed. It is
advisable to stop the filtration during maintenance operations on the
filtration system.
Regularly monitor the filter clogging level.
A weekly check is recommended for cleaning.
Minimum daily filtration operating time of 8 hours is recommended to ensure
clear pool water. It is essential to change any damaged element or set of
elements as soon as possible. Use only parts approved by person responsible
for placing the product on the market.
All filters and filter media shall be inspected regularly to ensure that there
is not a build-up of detritus thus preventing good filtration. The disposal of
any used filter media should also be in accordance with applicable
regulations/legislation.
In case of doubt on the pump or any circulation devices, contact a qualified
installer, or the manufacturer/importer/distributor. The water circulation
installation shall comply with the European as well as national/local
regulations, especially when dealing with electrical issues.
Any change of valve position, pump size, grille size can cause a change of the
flow and the suction velocity can be increased. Mind all the safety
requirements and recommendations described in the manual.
NOTE:
Please examine equipment before use. Notify Bestway at the customer service
address listed on this manual for any manufacturing defect or missing parts at
the time of purchase. Verify that the equipment components represent the
filter pump model that you had intended to purchase.
NOTE:
Place pump on a solid and level ground. Pay attention to position of pool and
pump so adequate ventilation, drainage, and access for cleaning is available.
Never place pump in an area that may accumulate water, or in an area where
foot traffic will flow around the pool.
It is necessary to have the plug accessible after installation of the pool.
NOTE:
Atmospheric conditions may affect the performance and life span of your filter
pump. Unnecessary wear and tear may occur during periods of cold, heat and
exposure to sun. Whenever possible shelter pump from these conditions.
It is important to ensure the factory equipped stopper plugs for the inlet and
outlet ports replace the screens before removal or maintenance on the pump is
attempted.
NOTE:
Do not add chemicals in the filter pump.
Don’t plug or unplug the appliance if hand is wet.
Always unplug the appliance:
- On raining days
- Before cleaning or other maintenance
- Leave it unattended on holidays
Safekeeping the instruction. For reconstruction the pool set every time, please always refer to the instructions.
If instruction is missed, please contact with Bestway or search it in website:
www.bestwaycorp.com
NOTE: This product is not intended for commercial use. Please read the
instruction manual carefully and keep it for future reference.
SAVE THESE INSTRUCTIONS.
DISPOSAL
Electrical products should not be disposed of with household waste. Please
recycle where facilities exist. Check with your local authority or retailer
for recycling advice.
ATTACHING A BASE
The filter pump must be vertically fixed on ground or a certain pedestal made
of wood or concrete before use. There should be two holes 7mm in diameter on
the pedestal, the space between which should be 256mm. Put filter pump on the
pedestal and fix them together by fasten the bolts and nuts. All the pedestal
parts should weigh over 18kgs at least to prevent the pump from accidental
falling.
NOTE: It is imperative to check that the hydraulic connectors are not
obturated.
OPERATION
- Open/unscrew the Air Purge Valve on the top of the Filter Pump; air is released as water fills the Filter Pump.
- When water comes out of the Air Purge Valve screw it closed and wipe away any water.
- To start the Filter Pump, insert the plug into a residual current device (RCD).
- To start the Filter Pump, insert the plug into a circuit of alternative residual power (DDR) For France Only.
- Turn on the switch to the “I” position.
IMPORTANT: DO NOT DRY RUN THE FILTER PUMP – Make sure both the pool’s Inlet and Outlet valves are fully covered by water before operating the Filter Pump.
PUMP MAINTENANCE
CAUTION: YOU MUST ENSURE THE FILTER PUMP IS UNPLUGGED BEFORE ANY MAINTENANCE BEGINS OR SEVERE RISK OF INJURY OR DEATH EXISTS.
- Unplug the Filter Pump.
- Stop water flowing to the Filter Pump refer to pool’s manual.
- Unscrew the Filter Cap Retainer and remove the Filter Cap.
- Clean the Filter Cartridge with a garden hose.
- Insert the cleaned (or new) Filter Cartridge; ensure it is centered in the Filter Pump.
- Check that the Filter Cap Seal is in place.
- Replace the Filter Cap and screw the Filter Cap Retainer into position.
- Open the valve A and B.
- Follow the Pump Installation Directions section to prepare the system for use.
IMPORTANT: For sanitary reasons we suggest replacing the Filter Cartridge with a new one every two weeks. Flush the filter daily.
PUMP STORAGE
- Unplug the Filter Pump.
- Stop water flowing into the Filter Pump and to remove the Filter Cartridge.
- Discard the Filter Cartridge.
- Detach all Hoses.
- Dry all components thoroughly.
- Store the filter pump in a dry location out of child’s reach. Storage temperature: 4-40°C (39.2-104°F)
- Drain the pool according to the Pool Owner’s Manual.
PUMP WARRANTY
For information concerning pump warranty please visit our website at: www.bestwaycorp.com