Altronix VertiLine24C Series CCTV Rack Mount Power Supplies Instruction Manual
- June 8, 2024
- Altronix
Table of Contents
Altronix VertiLine24C Series CCTV Rack Mount Power Supplies
Models Include
VertiLine24C
- 24VAC or 28VAC @ 10A
- Twenty-four (24) fuse-protected outputs
VertiLine246C
- 24VAC or 28VAC @ 14A
- Twenty-four (24) fuse-protected outputs
VertiLine24CD
- 24VAC or 28VAC @ 10A
- Twenty-four (24) PTC-protected outputs
VertiLine246CD
- 24VAC or 28VAC @ 14A
- Twenty-four (24) PTC-protected outputs
Overview
Altronix VertiLine CCTV Rack Mount Power Supplies provide 24 power outputs in a space-saving 1U EIA 19” rack mount chassis which may be rack, wall or shelf mounted. The units feature individually selectable 24VAC and/or 28VAC power outputs with surge suppression. VertiLine CCTV Rack Mount Power Supplies are also available in eight (8) and sixteen (16) output models with various power ratings.
Specifications
Input:
- 115VAC, 60Hz input.
Output:
- Twenty-four (24) individually selectable 24VAC or 28VAC power outputs with OFF position.
- Twenty-four (24) external blade fuse or PTC-protected outputs.
- Surge suppression.
Features:
- Twenty-four (24) power LED indicators.
- Removable terminal blocks with locking screw flange.
Features:
-
Illuminated master power disconnect
circuit breaker with manual reset. -
IEC 320 – 3-wire grounded line cord (detachable).
Mechanical:
- Units can be rack, wall or shelf mounted.
- Modular 1U standard EIA 19” rack mount chassis
- Enclosure Dimensions (H x W x D approx.): 1.625” x 19.125” x 8.5” (41.3mm x 486mm x 216mm).
Twenty-four (24) Output Rack Mount Configuration Reference Chart:
Altronix Model Number
| ****
Output Voltage (VAC)
| Total Output Current (Power)| Number of Outputs| ****
Output Protection
| Class 2 Rated Power- Limited Output Protection| Current (max. per output)| Fuse Rating| Main Fuse Rating| 115VAC 60Hz
Input Current
| ****
Agency Listings
| ****
UL Listings and File Numbers
---|---|---|---|---|---|---|---|---|---|---|---
VertiLine24C
| 24VAC or| ****
10A
| ****
24
| ****
Fused
| ****
–
| ****
3A
| ****
3A
| | | ****
| UL Listed for Commercial CCTV Equipment (UL 2044).
cUL Listed – CSA Standard
C22.2 No.1-04,
Audio, Video and Similar Equipment.
28VAC| 10A| 3A
VertiLine24CD| 24VAC or| ****
10A
| ****
24
| ****
–
| ****
PTC
| ****
2.5A
| ****
–
28VAC| |
VertiLine246C
| 24VAC or| ****
14A
| ****
24
| ****
Fused
| ****
–
| ****
3A
| ****
3A
| |
28VAC| 15A| 4A
VertiLine246CD
| 24VAC or| ****
14A
| ****
24
| ****
–
| ****
PTC
| ****
2.5A
| ****
–
28VAC| |
WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This installation should be made by qualified service personnel and should conform to the National Electrical Code and all local codes.
Installation Instructions
- Attach mounting brackets to VertiLine unit for rack or wall mount installation (Figs. 4-5, pg. 7). Affix rubber pads to VertiLine for shelf installation (Fig. 6, pg. 7).
- Secure the unit in a rack, mount the unit to a wall or place unit on a shelf as desired (the unit should be spaced at least 3” from any video monitors). When installing the unit in a rack, allow for one-half of a U spacing above the unit for ventilation.
- Plug the grounded AC line cord (included) into the IEC 320 connector of the VertiLine unit (Fig. 1f, pg. 4). Insert the plug end of the line cord into a grounded AC receptacle.
- Set the illuminated master power disconnect circuit breaker to the (ON) position (Fig. 3, pg. 6).
- Select 24VAC or 28VAC power output for cameras 1-24 with the corresponding voltage adjustment switches (Fig. 1b, pg. 4).
- Measure output voltage before connecting cameras. This helps avoid potential damage. All terminals with the common suffix (P) “1P, 2P …” are the same polarity.
- Set the illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 3, pg. 6).
- Connect the power outputs of terminals marked [1P & 1N] to the power inputs of camera 1 (Fig. 2, pg. 5). Repeat this step for each additional camera (Outputs 2-24). After the wiring is completed, insert the terminal block into the corresponding connector and secure by tightening the screws.
- Upon completion of the wiring, set the illuminated master power disconnect circuit breaker to the ON (RESET) position (Fig. 3, pg. 6).
- The power LEDs (Green) on the faceplate for Outputs 1-24 will illuminate when AC power is present (Fig. 1a, pg. 4). If any of these LEDs are off, a loss of AC power output may be due to a blown fuse or a tripped PTC caused by a short circuit or overload condition. If all of the LEDs are OFF, there may be a complete loss of supply power to the VertiLine unit or the illuminated master power disconnect circuit breaker is in the OFF position or the main fuse 1-12 or 13-24 is blown (Fig. 1c, pg. 4).*
To restore the power output for VertiLine24C or VertiLine246C:
- Switch the corresponding output voltage switch to the OFF position (Fig. 1b, pg. 4).
- Eliminate the trouble condition.
- Replace the corresponding automotive blade fuse.*
- Switch output voltage switch to the 24VAC or 28VAC position as desired (Fig. 1b, pg. 4).
To restore the power output for VertiLine24CD or VertiLine246CD:
- Switch the corresponding output voltage switch to the OFF position (Fig. 1b, pg. 4).
- Eliminate the trouble condition.
- Allow 1 minute for PTC to cool off.
- Switch the output voltage switch to the 24VAC or 28VAC position as desired (Fig. 1b, pg. 4).
Note: Replace fuses with the same type and rating:
Output fuses are rated @ 3A for all models.
Main fuse ratings:
10A for VertiLine24C and VertiLine24CD.
15A for VertiLine246C and VertiLine246CD.
VertiLine24CD and VertiLine246CD do not have output fuses on the rear of the rack mount chassis. The output PTCs are located on the inside of the rack mount chassis
.
Typical Hookup
The lightning flash with an arrowhead symbol within an equilateral triangle is
intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE
within the product’s enclosure that may be of sufficient magnitude to
constitute an electric shock.
The exclamation point within an equilateral triangle is intended to alert the
user to the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the appliance.
CAUTION: To reduce the risk of electric shock do not open the enclosure.
There are no user-serviceable parts inside. Refer servicing to qualified
service personnel.
1U EIA 19” Rack Mount Chassis
Mechanical Drawing & Dimensions (H x W x D):
1.625” x 19.125” x 8.5” (41.3mm x 486mm x 216mm)
Front
Power Switch With Built-In Circuit Breaker:
OFF position – Switch not illuminated. Outputs not powered. RESET (ON)
position – Switch illuminated. Outputs powered. Circuit breaker tripped –
Switch not illuminated. Power LEDs on the faceplate are not illuminated.
Outputs not powered. To reset the circuit breaker set the power switch to the
ON (RESET) position (Fig. 3, pg. 6)
Mounting Options
Rack Mount Installation
- Remove factory-installed screws from both sides of the rack chassis (Fig. 4a).
- Install mounting brackets (A) on the left and right side of the rack chassis using the two (2) flat head screws (B) (included) (Fig. 4b).
- Place unit into desired EIA 19” rack position and secure it with mounting screws (not included) (Fig. 4c)
Wall Mount Installation
- Install mounting brackets (A) on the left and right side of the rack chassis using two (2) flat head screws (B) (included) (Fig. 5a).
- Place unit at the desired location and secure it with mounting screws (not included) (Fig. 5b).
Caution: It is necessary to make sure mounting screws are securely fastened to a beam when installing.
Shelf Installation
- Position and affix rubber pads (C) (included) at each corner on the bottom of the unit (Fig. 6).
- Place the unit in the desired location.
Mounting Hardware (Included):
- Two (2) mounting brackets
- Six (6) flat head screws for mounting brackets.
- Four (4) rubber pads.
Altronix is not responsible for any typographical errors. 140 58th Street,
Brooklyn, New York 11220 USA | phone:
718-567-8181 | fax:
718-567-9056
website: www.altronix.com | e-mail:
info@altronix.com | Lifetime Warranty
IIVertiLine24C Series