Aeotec Door/ Window Sensor 6 ZW112-D Manual
- June 8, 2024
- Aeotec
Table of Contents
- Aeotec
- Door/ Window Sensor 6
- SKU: ZW112-D
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Communication to a Sleeping device (Wakeup)
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: Which value of the Sensor Binary Report or Basic Set will be
- Parameter 101: Enable/disable the function of parameter 111
- Parameter 111: Set the interval time of low battery checking.
- Parameter 121: To configure which sensor report will be sent when the
- Parameter 252: Lock/unlock all configuration parameters.
- Parameter 255: Reset the Sensor.
- Parameter 39: Set the low battery value.
- Technical Data
- Supported Command Classes
- Controlled Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Aeotec
Door/ Window Sensor 6
SKU: ZW112-D
Quickstart
This is a
secure
Alarm Sensor
for
Hong Kong.
Please make sure the internal battery is fully charged.
To add this device to your network execute the following action:
Turn the primary controller of Z-Wave network into inclusion mode, short press
the products Action Button that you can find in the back of the product.
Please refer to the
Manufacturers
Manual
for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Aeon Labs Door/ Window Sensor 6 is a smart Z-Wave sensor that can detect the status of door/window’s open/close in real time. Its a security Z-Wave device that supports security encryption. Also it supports the Over the Air Firmware Updating that allows you wirelessly update its firmware if needs. It can be included and operated in any Z-Wave network with other Z-Wave certified devices from manufacturers and/or other applications.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
Press the Action Button once that you can find in back of the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action Button that you can find in the back of the product.
Exclusion
Turn the primary controller of Z-Wave network into exclusion mode, short press the products Action Button that you can find in back of the product.
Communication to a Sleeping device (Wakeup)
This device is battery operated and turned into deep sleep state most of the
time
to save battery life time. Communication with the device is limited. In order
to
communicate with the device, a static controller C is needed in the
network.
This controller will maintain a mailbox for the battery operated devices and
store
commands that can not be received during deep sleep state. Without such a
controller,
communication may become impossible and/or the battery life time is
significantly
decreased.
This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the
desired
wakeup interval and the node ID of the controller. If the device was included
by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please
perform
the following action:
Press the Action Button once, which will trigger sending out the Wake up notification command, press and hold the Action Button for 3 seconds, which will toggle on/off the Sensor be waked up for 10 minutes.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 5| Group 1 is assigned to the Lifeline association group and every device
has 5 nodes to associate. The sensor binary report, basic set or notification
report command can be sent in this group when the Sensor is triggered.
---|---|---
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Which value of the Sensor Binary Report or Basic Set will be
sent when the door is Opened/Closed.
To set which value of the Sensor Binary Report or Basic Set will be sent
when the door is Opened/Closed.
Size: 1 Byte, Default Value: 1
SettingDescription
0| Sensor Binary Report/Basic Set =0xFF when the door is opened, Sensor Binary
Report/Basic Set= 0x00 when the door is closed.
---|---
1| Sensor Binary Report/Basic Set= 0x00 when the door is opened, Sensor Binary
Report/Basic Set=0xFF when the door is closed.
Parameter 101: Enable/disable the function of parameter 111
Enable/disable the function of parameter 111.Note: this parameter cannot
disable the low battery checking of the Sensor itself.
Size: 1 Byte, Default Value: 1
SettingDescription
0 | Disable. |
---|---|
1 | Enable. |
Parameter 111: Set the interval time of low battery checking.
Set the interval time of low battery checking.Note:1, if the value is less
than 10, the time unit is second.If the value is more than 10, the time unit
is 4 minutes, which means if the value is more than 10 and less than 240, the
interval time is 4 minutes. If the value is more than 240 and less than 480,
the interval is 8 minutes.2, if the current battery report falls below the low
battery value (configurable parameter 39), it will send battery report=0xFF.
Size: 4 Byte, Default Value: 86640
SettingDescription
0 – 2147483647 | The range of interval can be set to 0 to 2147483647. |
---|
Parameter 121: To configure which sensor report will be sent when the
door is opened/closed.
To configure which sensor report will be sent when the door is
opened/closed.
Size: 1 Byte, Default Value: 1
SettingDescription
1 | Basic Set CC is selected. |
---|---|
2 | Sensor Binary Report CC is selected. |
3 | Basic Set CC and Sensor Binary Report CC are selected. |
Parameter 252: Lock/unlock all configuration parameters.
Lock/unlock all configuration parameters.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Unlock. |
---|---|
1 | Lock. |
Parameter 255: Reset the Sensor.
Reset the Sensor.
Size: 4 Byte, Default Value: 0
SettingDescription
0 | Reset to default settings. |
---|---|
1431655765 | Reset to default settings and excluded from the network. |
Parameter 39: Set the low battery value.
Set the low battery value.(10% to 50%).
Size: 1 Byte, Default Value: 20
SettingDescription
10 – 50 | The range of low battery value can be set to 10% to 50%. |
---|
Technical Data
Hardware Platform | ZM5101 |
---|---|
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 112 FW: 1.03 |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-17085746 |
Z-Wave Product Id | 0x0086.0x0302.0x0070 |
Sensors | Open/Closed (Binary) |
Supported Notification Types | Access Control |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Supported Command Classes
- Association Grp Info
- Association V2
- Battery
- Configuration
- Device Reset Locally
- Firmware Update Md V2
- Manufacturer Specific V2
- Notification V4
- Powerlevel
- Security
- Sensor Binary
- Version V2
- Wake Up V2
- Zwaveplus Info V2
Controlled Command Classes
- Basic
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.