EdgeMAX ER-4 Edge Router User Guide

June 3, 2024
EdgeMAX

EdgeMAX ER-4 Edge Router

EdgeMAX-ER-4-Edge-Router-User-Gu

Package

Installation Requirements

  • Drill with a 6 mm drill bit (for wall mounting)
  • Phillips screwdriver
  • For indoor applications, use Category 5 (or above) UTP cabling approved for indoor use.
  • For outdoor applications, shielded Category 5 (or above) cabling should be used for wired Ethernet connections and should be grounded through the AC ground of the power supply.
  • We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial-grade, shielded Ethernet cables from
  • Ubiquiti. For more details, visit: ui.com/toughcable
  • WARNING
    To reduce the risk of fire or electric shock, do not expose the EdgeRouter to rain or moisture.

Note
Although the cabling can be located outdoors, the EdgeRouter itself should be housed inside a protective enclosure.

Overview

Note
The System LED functionality has been updated with firmware v1.10.7. We recommend that you update the EdgeRouter to the latest firmware.

Hardware Installation

WARNING
FAILURE TO PROVIDE PROPER VENTILATION MAY CAUSE FIRE HAZARDS. KEEP AT LEAST 20 MM OF CLEARANCE NEXT TO THE VENTILATION HOLES FOR INADEQUATE AIRFLOW.

Wall Mounting

Grounding the EdgeRouter (Recommended)
The Power Cord grounds the device; however, you can add optional ESD grounding for enhanced ESD protection.

  1. Attach a screw (not included) to secure a ground wire (not included) to the GroundingPoint
  2. Secure the other end of the ground wire to a grounding block.
  3. Connect the Power Cord to the Power port and a power outlet.

Using SFP Ports

For information about compatible fiber SFP modules, visit ubnt.link/SFP_DAC_Compatibility

Accessing the EdgeOS Configuration Interface
The EdgeOS® configuration interface can be accessed via DHCP or static IP address assignment. By default, is set up as a DHCP client.

To check the IP address of the EdgeRouter, use one of the following methods: Set up the DHCP server to provide a specific IP address to the EdgeRouter based on its MAC address (on the label). Let the EdgeRouter obtain an IP address and then check the DHCP server to see which IP address was assigned. Launch your web browser. Enter the appropriate IP address in the address field.

The EdgeOS Configuration Interface will appear, allowing you to customize your settings as needed. For more information, refer to the EdgeOS User Guide, which is available at ui.com/download/edgemax

Static IP Address
Connect an Ethernet cable from the Ethernet port on your computer to the port labeled eth0 on the EdgeRouter.

Configure the Ethernet adapter on your host system with a static IP address on the the192.168.1.x subnet.

The EdgeOS Configuration Interface will appear, allowing you to customize your settings as needed. For more information, refer to the EdgeOS User Guide, which is available at ui.com/download/edgemax

UNMS Management

You can manage your device using UNMS, which lets you configure, monitor, upgrade, and back up your devices using a single application. Get started at www.unms.com

Specifications

Safety Notices

  1. Read, follow, and keep these instructions.
  2. Heed all warnings.
  3. only use attachments/accessories specified by the manufacturer.

WARNING
Failure to provide proper ventilation may cause fire hazards. Keep at least 20 mm of clearance next to the ventilation holes for adequate airflow.

WARNING
To reduce the risk of fire or electric shock, do not expose this product to rain or moisture.

WARNING
Do not use this product in a location that can be submerged by water.

WARNING
Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.

Electrical Safety Information
Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment, or pose a fire hazard if the limitations are not followed.

  1. This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet
    • The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.
    • Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.
    • Protective earthing is provided by a Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.
    • Protective bonding must be installed in accordance with local national wiring rules and regulations

Limited Warranty

ui.com/support/warranty
The limited warranty requires the use of arbitration to resolve disputes on an individual basis, and, where applicable, specify arbitration instead of jury trials or class actions.

Compliance

FCC
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

ISED Canada
CAN ICES-3(A)/NMB-3(A)

WEEE Compliance Statement 2022 Ubiquiti Inc. All rights reserved.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>