ID Lock 101 ID-101 Manual

June 8, 2024
ID Lock

ID Lock

ID Lock 101

SKU: ID-101

Quickstart

This is a
secure
Door Lock – Keypad
for
CEPT (Europe)
.

Please make sure the internal battery is fully charged.

To add this device to your network execute the following action:
Inclusion(Puts your device in inclusion mode) Push and hold button until all LEDs on keypad activates. (with ID Lock in an unlocked state) Release button and press 8 on keypad.Inclusion mode starts immediately. LED indicator below logo signals this by flashing blue.

Please refer to the
Manufacturers Manual
for more information.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

UART console communication module turns your ID Lock digital doorlock into a Z-Wave Plus enabled digital doorlock.It enables your ID Lock to operate in a Z-Wave network with numerous access control funtions and notifications.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This
procedure should only be used when the primary controller is inoperable.

Device reset(This will reset RF interface module to factory default settings)Warning: Please do only proceed with the following reset procedure, if primary network controller is missing or otherwiseinoperable.RESET Z-WAVE MODULE:Activate doorlock service menu, by holding inside push button for 5sec while door is in OPEN state.Outside touchpanel activates > Push “0”FACTORY RESET DOORLOCK FIRMWARE:1. Push innside pushbutton continously for five Seconds after inserting batteries.2. Receive reset sound3. Receive confirmation sound

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Inclusion

Inclusion(Puts your device in inclusion mode) Push and hold button until all LEDs on keypad activates. (with ID Lock in an unlocked state) Release button and press 8 on keypad.Inclusion mode starts immediately. LED indicator below logo signals this by flashing blue.

Exclusion

Exclusion(Puts your device in exclusion mode) Push and hold button until all LEDs on keypad activates. (with ID Lock in an unlocked state) Release button and press 8 on keypad.Exclusion mode starts immediately. LED indicator below logo signals this by flashing blue.

Communication to a Sleeping device (Wakeup)

This device is battery operated and turned into deep sleep state most of the time
to save battery life time. Communication with the device is limited. In order to
communicate with the device, a static controller C is needed in the network.
This controller will maintain a mailbox for the battery operated devices and store
commands that can not be received during deep sleep state. Without such a controller,
communication may become impossible and/or the battery life time is significantly
decreased.

This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the desired
wakeup interval and the node ID of the controller. If the device was included by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please perform
the following action:

Activate by touching numpad with two fingers or handpalm

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1 5 Z-Wave Plus Lifeline

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: Doorlock mode

Doorlock operational behaviour
Size: 1 Byte, Default Value: 0

SettingDescription

3 Away mode and Automatic locking mode
0 Disabled Away mode and Manual locking mode
2 Away mode and Manual locking mode
1 Disabled Away mode and Automatic locking mode

Parameter 10: Retrieve Registered User ID information

Configuration GET for retriving UID informationRetrival of registered UIDs on parameter number 10 to 59Parameter number is representing UID indexEx. UID index 1 = parameter 10UID index 50 = parameter 59
Size: 4 Byte, Default Value: 0

SettingDescription

10 – 59 RFID Card Index Number + 9

Parameter 2: RFID Configuration Set and Report

This parameter configures RFID cards to work with the door lock by setting the parameter to specific values.After setting an RFID card to the door lock, the result and configuration can be read.
Size: 2 Byte, Default Value: 0

SettingDescription

1 Begin RFID Card Registration
2 RFID Registration Failed
3 Successful RFID Card Registration – 2nd byte contains Index Number
5 RFID Card Registration Mode was not started
6 RFID Card Registration Mode In Progress
4 RFID Card Registration Mode Finished

Technical Data

Hardware Platform ZM5202
Device Type Door Lock – Keypad
Network Operation Listening Sleeping Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 6.51.06
Certification ID ZC10-17055585
Z-Wave Product Id 0x0230.0x0030.0x0001
Supported Notification Types Access Control
Sensors Air TemperatureOpen/Closed (Binary)RF Signal StrengthVoltage
Outdoor Use ok
IP (Ingress Protection) Rated ok
Firmware Updatable Updatable by Consumer by RF
Door Lock Type Deadbolt Motor Attachment
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Association Grp Info
  • Association V2
  • Battery
  • Configuration
  • Device Reset Locally
  • Door Lock V2
  • Firmware Update Md V2
  • Manufacturer Specific V2
  • Notification V4
  • Powerlevel
  • Security
  • User Code
  • Version V2
  • Zwaveplus Info V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals