Secure Controls Secure Smart Plug 302 SSP 302 UE Manual
- June 8, 2024
- Secure Controls
Table of Contents
- Secure Controls
- Secure Smart Plug 302
- SKU: SSP 302 UE
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Communication to a Sleeping device (Wakeup)
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: Switch Status delta based configuration
- Parameter 10: Current time interval based
- Parameter 11: Power Factor time interval based
- Parameter 12: Active Power time interval based
- Parameter 13: Active Energy time interval based
- Parameter 14: Apparent Energy time interval based
- Parameter 15: Relay and LED configuration
- Parameter 16: Sleep Current Configuration
- Parameter 2: Voltage delta based configuration
- Parameter 3: Current delta based configuration
- Parameter 4: Power Factor delta based configuration
- Parameter 5: Active Power delta based configuration
- Parameter 6: Active Energy delta based configuration
- Parameter 7: Apparent Energy delta based configuration
- Parameter 8: Switch Status time interval based
- Parameter 9: Voltage time interval based
- Technical Data
- Controlled Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Secure Controls
Secure Smart Plug 302
SKU: SSP 302 UE
Quickstart
This is a ****
On/Off Power Switch
for
CEPT (Europe).
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
To include the SSP 302 onto a network, put the controller into inclusion mode.
Now, press and hold the button on SSP 302 for 4 to 7 seconds then release. The
network status LED will start flashing (twice per second) on successful start
of inclusion process. On successful inclusion the LED will turn off.
Please refer to the
Manufacturers
Manual
for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
SSP 302 EU variant is a mains-powered, plug-in device that supports energy monitoring. It is suitable for switching loads up to 3.6KW at 230V AC. It can measure voltage, current, power, energy etc. The SSP 302 acts as a repeater in a Z-Wave network by helping messages from other devices reach there destinations, without losing a plug socket.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
Please use this procedure only when the primary controller is missing or otherwise inoperable. Power cycle the device and press and hold the button for more than 11 seconds and less than 15 seconds within the 60 seconds of power cycle to put the device in factory default, that include setting all the configuration, Association to factory default and removing the device from Z-Wave network.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
To include the SSP 302 onto a network, put the controller into inclusion mode. Now, press and hold the button on SSP 302 for 4 to 7 seconds then release. The network status LED will start flashing (twice per second) on successful start of inclusion process. On successful inclusion the LED will turn off.
Exclusion
To exclude the SSP 302 from a network, put the controller into exclusion mode. Now, press and hold the button on SSP 302 for 4 to 7 seconds then release. The network status LED will start flashing (twice per second) on successful start of exclusion process.After successful exclusion the network status LED will start flashing once per second, and the device will reset to factory default.
Communication to a Sleeping device (Wakeup)
This device is battery operated and turned into deep sleep state most of the
time
to save battery life time. Communication with the device is limited. In order
to
communicate with the device, a static controller C is needed in the
network.
This controller will maintain a mailbox for the battery operated devices and
store
commands that can not be received during deep sleep state. Without such a
controller,
communication may become impossible and/or the battery life time is
significantly
decreased.
This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the
desired
wakeup interval and the node ID of the controller. If the device was included
by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please
perform
the following action:
NA
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 4| Z-Wave Plus Lifeline.In this group Energy (Active Energy, Apparent
Energy) , Switch Status data will be reported base on the delta or time
interval configuration.
---|---|---
2| 4| Power, In this group ActivePower data will be reported base on the delta
or time interval configuration.
3| 4| Electrical Parameter,In this group Voltage, Current and Power Factor
data will be reported base on the delta or time interval configuration.
4| 4| Relay Status,In this group Switch Status data will be reported base on
the delta or time interval configuration.
5| 1| Time,In this device will sync the time and date from the time master in
the network.
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Switch Status delta based configuration
This configuration Parameter will be used to enable/disable the delta base
switch status reporting.
Size: 1 Byte, Default Value: 1
SettingDescription
Parameter 10: Current time interval based
This configuration Parameter will be used to set the time interval base
reporting of currentin 1 second resolution.
Size: 2 Byte, Default Value: 0
SettingDescription
Parameter 11: Power Factor time interval based
This configuration Parameter will be used to set the time interval base
reporting of Power Factor in 1 second resolution.
Size: 2 Byte, Default Value: 0
SettingDescription
Parameter 12: Active Power time interval based
This configuration Parameter will be used to set the time interval base
reporting of Active Power in 1 second resolution.
Size: 2 Byte, Default Value: 0
SettingDescription
Parameter 13: Active Energy time interval based
This configuration Parameter will be used to set the time interval base
reporting of Active Energy in 1 second resolution.
Size: 2 Byte, Default Value: 0
SettingDescription
Parameter 14: Apparent Energy time interval based
This configuration Parameter will be used to set the time interval base
reporting of Apparent Energy in 1 second resolution.
Size: 2 Byte, Default Value: 0
SettingDescription
Parameter 15: Relay and LED configuration
This configuration is used to change the relay LED status when relay is
open/close and also enable to whether to retain the last relay status over
power cycle.
Size: 1 Byte, Default Value: 0
SettingDescription
0| Relay status will not be retain over power cycle, and Relay status LED will
lit when relay ON and relay status LED will off when relay OFF.
---|---
1| Relay status will be retain over power cycle, and Relay status LED will lit
when relay ON and relay status LED will off when relay OFF.
2| Relay status will not be retain over power cycle, and Relay status LED will
off when relay ON and relay status LED will lit when relay OFF.
3| Relay status will be retain over power cycle, and Relay status LED will off
when relay ON and relay status LED will lit when relay OFF.
Parameter 16: Sleep Current Configuration
This configuration is used to disconnect the load if the device current is
less the configured sleep current for more than 30 seconds, this configuration
has the resolution of0.001 A .
Size: 1 Byte, Default Value: 0
SettingDescription
Parameter 2: Voltage delta based configuration
This configuration Parameter will be used to enable/disable the delta base
voltage reporting. Resolution of this parameter is 100 mV.if user wants to set
10V delta then it should be 10/0.1 = 100.
Size: 2 Byte, Default Value: 0
SettingDescription
Parameter 3: Current delta based configuration
This configuration Parameter will be used to enable/disable the delta base
curenrt reporting. Resolution of this parameter is 10 mA.if user wants to set
1A delta then it should be 1/0.01 = 100.
Size: 1 Byte, Default Value: 0
SettingDescription
Parameter 4: Power Factor delta based configuration
This configuration Parameter will be used to enable/disable the delta base
Power Factor reporting in 0.1% resolution. if user wants to set Power Factor
10% = 10/0.1 = 100
Size: 2 Byte, Default Value: 0
SettingDescription
Parameter 5: Active Power delta based configuration
This configuration Parameter will be used to enable/disable the delta base
Active Power reporting in 1 W resolution.
Size: 2 Byte, Default Value: 0
SettingDescription
Parameter 6: Active Energy delta based configuration
This configuration Parameter will be used to enable/disable the delta base
Active Energyreporting in 1 Wh resolution.
Size: 2 Byte, Default Value: 0
SettingDescription
Parameter 7: Apparent Energy delta based configuration
This configuration Parameter will be used to enable/disable the delta base
Apparent Energy reporting in 1 VAh resolution.
Size: 2 Byte, Default Value: 0
SettingDescription
Parameter 8: Switch Status time interval based
This configuration Parameter will be used to set the time interval base
reporting of switch status in 1 second resolution.
Size: 2 Byte, Default Value: 0
SettingDescription
Parameter 9: Voltage time interval based
This configuration Parameter will be used to set the time interval base
reporting of voltagein 1 second resolution.
Size: 2 Byte, Default Value: 0
SettingDescription
Technical Data
Hardware Platform | ZM5202 |
---|---|
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | 01 |
Z-Wave Version | 6.51.02 |
Certification ID | ZC10-15020014 |
Z-Wave Product Id | 0x0059.0x0011.0x0001 |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Controlled Command Classes
- Time
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.