Secure Controls Indoor Sensor for Temperature and Humidity SECESES303 Manual

June 8, 2024
Secure Controls

Secure

Indoor Sensor for Temperature and Humidity

SKU: SECESES303

Quickstart

This is a ****

Measuring Sensor Device
for
Europe
.

Please make sure the internal battery is fully charged.

AFit the two supplied AA batteries. The battery compartment is marked with a plus and minus sign. Ensure that each battery is correctly aligned. The SES 303 will now power up.

Step 1: On the Z-Wave controller, select Include if you are adding a device to the network or select Exclude if you are removing a device from the network. Check with the controller manufacturer?s manual.

Step 2: On the SES SES 303, press the button, hold and release after 1 second to send a request (Network Information Frame) to join the network.

On successful inclusion the LED will flash 2 times. The total process can take up to 20 seconds; refer to the ?Radio? section for details. If the LED flashes 4-times this means that the inclusion process has failed, so try moving the SES 303 to another position and repeat the Inclusion steps. If the inclusion process fails again, the device may be already included in another network. So first exclude and then include the device. The controller will show when the inclusion/ Exclusion operation is successful.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

The SES303 sensor is powered from 2XAA batteries and it is Z-Wave Plus certified. In addition to the standard functionality they also support one of the following optional configurations:

One external NTC wired temperature sensor (SES 001)

Four external wired pipe/tank temperature sensors (SES 002) each connected by a 1 meter long cable.

One external wired pipe/tank temperature sensor (SES 003), connected by a cable of 4 meters long.

This unit is ideal for temperature and humidity measurement for smart central heating controls or any other similar application. Its user interface is straightforward and with a push button and LED indication on back side, one can easily include/exclude this to a Z-Wave network.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Installation

Keep the SES 303 in its sealed pack until all dust and debris have been cleared away prior to making connections. Remove the wall plate from the rear of the SES 303.

a) The wall plate can be released by pressing the spring clips on the bottom of the wall plate

b) While pressing spring clips, swing the wall plate out and down to remove.

Choose the position where the unit is to be mounted (refer to the following layout). Avoid locations alongside or behind large metal surfaces that could interfere with the low power radio signals between the unit and the controller. The sensor should be mounted on an internal wall, approximately 1.5 metres (5 feet) above floor level and away from draughts, direct heat sources and sunlight. Make sure that there is sufficient space around the unit to allow easy access to the two retaining spring clips on the base of the wall plate. It may be necessary to move the sensor around to ensure good communication. Do not attempt to mount it on the wall until it has been included on the network.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Inclusion

Fit the two supplied AA batteries. The battery compartment is marked with a plus and minus sign. Ensure that each battery is correctly aligned. The SES 303 will now power up.

Step 1: On the Z-Wave controller, select Include if you are adding a device to the network or select Exclude if you are removing a device from the network. Check with the controller manufacturer?s manual.

Step 2: On the SES SES 303, press the button, hold and release after 1 second to send a request (Network Information Frame) to join the network.

On successful inclusion the LED will flash 2 times. The total process can take up to 20 seconds; refer to the ?Radio? section for details. If the LED flashes 4-times this means that the inclusion process has failed, so try moving the SES 303 to another position and repeat the Inclusion steps. If the inclusion process fails again, the device may be already included in another network. So first exclude and then include the device. The controller will show when the inclusion/ Exclusion operation is successful.

Exclusion

Fit the two supplied AA batteries. The battery compartment is marked with a plus and minus sign. Ensure that each battery is correctly aligned. The SES 303 will now power up.

Step 1: On the Z-Wave controller, select Include if you are adding a device to the network or select Exclude if you are removing a device from the network. Check with the controller manufacturer?s manual.

Step 2: On the SES SES 303, press the button, hold and release after 1 second to send a request (Network Information Frame) to join the network.

On successful inclusion the LED will flash 2 times. The total process can take up to 20 seconds; refer to the ?Radio? section for details. If the LED flashes 4-times this means that the inclusion process has failed, so try moving the SES 303 to another position and repeat the Inclusion steps. If the inclusion process fails again, the device may be already included in another network. So first exclude and then include the device. The controller will show when the inclusion/ Exclusion operation is successful.

Product Usage

The association process is applicable only after the device is included into network. Please note that some controllers can automatically associate. Always check with the manufacturer?s manual.

Step 1: Put the controller into Association Mode.

Step 2: Press and hold SES 303 button for more than 1 second and then release.

Step 3: The controller will confirm association when the process is successfully completed.

RF communication check after installation Press button for less than 1 second. The SES 303 will send temperature report of onboard sensor. Note: this feature only works when the device has been included in network and the nodes associated. Sending Node Information- Press and hold SES 303 button for more than 1 second and then release.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1| 2|
---|---|---

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: Delta Temperature

__
Size: 1 Byte, Default Value: 0

SettingDescription

1 – 125 0,1 – 12,5 “°C
130 – 255 -0,1 – -12,5 “°C

Parameter 2: Temp Reporting Interval

__
Size: 1 Byte, Default Value: 5

SettingDescription

1 – 255 Time in minutes

Parameter 3: Delta Humidity

__
Size: 1 Byte, Default Value: 5

SettingDescription

1 – 125 0,1 – 12,5 %RH
130 – 255 -0,1 – -12,5 %RH

Parameter 4: Humidity Reporting Interval

__
Size: 1 Byte, Default Value: 5

SettingDescription

1 – 255 Time in minutes

Technical Data

Dimensions 0.0850000×0.0850000×0.0310000 mm
Weight 160 gr
EAN 5015914840098
Device Type Routing Multilevel Sensor
Generic Device Class Multilevel Sensor
Specific Device Class Routing Multilevel Sensor
Firmware Version 01.00
Z-Wave Version 03.5f
Certification ID ZC10-15010003
Z-Wave Product Id 0059.000d.0003
Frequency Europe – 868,4 Mhz
Maximum transmission power 5 mW

Supported Command Classes

  • Basic
  • Sensor Multilevel
  • Association Grp Info
  • Device Reset Locally
  • Zwaveplus Info
  • Configuration
  • Manufacturer Specific
  • Powerlevel
  • Battery
  • Wake Up
  • Association
  • Version

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Secure Controls User Manuals

Related Manuals