Vision Security Siren with LED strobe light VISEZM1601-5 Manual
- June 8, 2024
- Vision Security
Table of Contents
- Vision Security
- Siren with LED strobe light
- SKU: VISEZM1601-5
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Installation
- Inclusion/Exclusion
- Product Usage
- Communication to a Sleeping device (Wakeup)
- Quick trouble shooting
- Firmware-Update over the Air
- Association – one device controls an other device
- Configuration Parameters
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Vision Security
Siren with LED strobe light
SKU: VISEZM1601-5
Quickstart
This is a ****
Siren
for
Europe.
To run this device please insert fresh *4 LR6 AA** batteries.
Please make sure the internal battery is fully charged.
To add this device to your network execute the following action:
To get the ZM 1601 in the inclusion” mode, open the bracket and press the
program switch of ZM 1601 for 1 second at least & release to be included.
After waiting a few seconds the LED Setting Lighting should go off, if not,
please try again.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
This product will sound a loud siren and flash a strobe light when an alarm message or alert is received on any Z-Wave enabled network. This siren is a Z-Wave enabled device (interoperable, two-way RF mesh networking technology) and is fully compatible with any Z-Wave enabled network. Configuration modes are provided to select; Strobe, Siren or Both and to set Alarm Auto Stop time. Features also include Self-Protection (tamper proof) alert and Battery Life Alert. 105dB siren at 1 meter.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
All user and network settings will be cleared and the device reset to factory defaults when the device is excluded.
Safety Warning for Batteries
The product contains batteries. Please remove the batteries when the device is
not used.
Do not mix batteries of different charging level or different brands.
Installation
Note: If you are installing the entire Z-Waveâ„¢ system for the first time, please refer to the” installation guide of Z-Waveâ„¢ Interface Controller before installing ZM 1601.
1. Remove the bracket from the siren by press the locking tab, and then gently slide up the siren. Observe the correct polarity before insert the batteries.
2. Using the screws or adhesive tape to affix the bracket on the chosen location.
3. Slide back the front cover, and then the LED should go off.
4. LED Status for Z-Wave Network:
-
After power on, the orange LED will flash if the siren has not been included yet.
-
After power on, the orange LED will go off if the siren has been included.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
To get the ZM 1601 in the inclusion” mode, open the bracket and press the program switch of ZM 1601 for 1 second at least & release to be included. After waiting a few seconds the LED Setting Lighting should go off, if not, please try again.
Exclusion
Press the program switch of ZM 1601 for 1 second at least & release to be excluded. Note: a. LED setting light will flash (orange color) continuously in Exclusion condition for 25 seconds.
Product Usage
1. Normal operation , the LED light will not on.
2. Alarm Mode:
Active: ” It will active the Alarm Mode after receiving Basic Set (ON) or Binary” Switch (ON). The LED-ARRAY & SIREN will be actived according to the” Configuration’s setting value.
Stop: ” It will stop the Alarm Mode after receiving Basic Set (OFF) or Binary Switch” (OFF) which depends on Configuration’s setting value.”
Auto Stop: ” After stopping alarm, it will send Binary Switch Report (0x00)
3. Self-Protection Mode: ” After put back the bracket over 5 seconds, ZM 1601 will” enter the Self-Protection Mode which will active “LED_ARRAY & SIREN at the” same time. The Alarm Mode will be triggered If the back cover has been opened
during the Self-Protection Mode The Stop method is same as the Alarm Mode.” Open the bracket or close the bracket after 5 seconds will sent notification
Communication to a Sleeping device (Wakeup)
This device is battery operated and turned into deep sleep state most of the
time
to save battery life time. Communication with the device is limited. In order
to
communicate with the device, a static controller C is needed in the
network.
This controller will maintain a mailbox for the battery operated devices and
store
commands that can not be received during deep sleep state. Without such a
controller,
communication may become impossible and/or the battery life time is
significantly
decreased.
This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the
desired
wakeup interval and the node ID of the controller. If the device was included
by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please
perform
the following action:
It is FLiRS device
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Firmware-Update over the Air
This device is capable of receiving a new firmware ‘over the air’. The update
function
needs to be supported by the central controller. Once the controller starts
the update
process, perform the following action to confirm the firmware update:
Support OTA Firmware update from controller.
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 5 | LifeLine association for central static controller |
---|
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Siren/Strobe Mode
__
Size: 1 Byte, Default Value: 0
SettingDescription
0 | All Enable |
---|---|
1 | Siren only |
2 | Storbe only |
Parameter 2: Alarm Auto Stop Time
__
Size: 1 Byte, Default Value: 0
SettingDescription
0 | 30 seconds |
---|---|
1 | 60 seconds |
2 | 120 seconds |
3 | unlimited |
Technical Data
Dimensions | 115x77x38 mm |
---|---|
Weight | 130 gr |
Hardware Platform | ZM5202 |
EAN | 0019962005404 |
Battery Type | 4 * LR6 AA |
Device Type | Siren |
Network Operation | Listening Sleeping Slave |
Z-Wave Version | 6.51.00 |
Certification ID | ZC10-14040001 |
Z-Wave Product Id | 0x0109.0x2005.0x0505 |
Frequency | Europe – 868,4 Mhz |
Maximum transmission power | 5 mW |
Supported Command Classes
- Association
- Association Group Information
- Basic
- Battery
- Configuration
- Device Reset Locally
- Firmware Update Md
- Manufacturer Specific
- Notification
- Powerlevel
- Switch Binary
- Version
- Zwaveplus Info
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>