Sensative Strips Multi Sensor Comfort SENECOMFORT Manual
- June 8, 2024
- SENSATIVE
Table of Contents
- Sensative
- Strips Multi Sensor Comfort
- SKU: SENECOMFORT
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Product Usage
- Communication to a Sleeping device (Wakeup)
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 2: LED alarm event reporting
- Parameter 3: Temperature & Light reporting frequency
- Parameter 4: Temperature reporting
- Parameter 5: Temperature reporting unit
- Parameter 6: Temperature alarms
- Parameter 7: High temperature alarm level
- Parameter 8: Low temperature alarm level
- Parameter 9: Ambient light reporting
- Parameter 10: High ambient light report level
- Parameter 11: Low ambient light report level
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Sensative
Strips Multi Sensor Comfort
SKU: SENECOMFORT
Quickstart
This is a ****
Alarm Sensor
for
Europe.
To run this device please insert fresh *1 Lithium** batteries.
Please make sure the internal battery is fully charged.
To add this device to your network execute the following action:
Move the magnet to the rounded” edge, and once the LED blinks, move the magnet away
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Your Strips Comfort is a Z-Wave multi-sensor that can be added to any certified Z-Wave system and operate with any Z-Wave device.” Strips Comfort is a discreet temperature and light sensor.
Strips Comfort has a range up to 40 meters. The range can be extended by using any non-battery Z-wave device, which automatically acts as a repeater when placed between Strips Comfort and the controller.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
Move the magnet to the rounded” edge, and once the LED blinks, move the magnet away, on the 3rd repetition, leave the magnet as” shown in the figure below (20mm from the rounded edge) for 10 seconds.
Safety Warning for Batteries
The product contains batteries. Please remove the batteries when the device is
not used.
Do not mix batteries of different charging level or different brands.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
Move the magnet to the rounded” edge, and once the LED blinks, move the magnet away
Exclusion
Move the magnet to the rounded” edge, and once the LED blinks, move the magnet away (See figure below)
Product Usage
Please note that poor network reliability will affect Strips Comfort”´s battery life. When Strips Comfort blinks 5 times, this indicates that Strips Comfort failed to communicate with the controller. If it happens frequently you may move the controller closer or add an extender between the controller and Strips Comfort.
LED LIGHT SIGNALS
1 short blink: User commands (Table C) or alarm event feedback – when Strips is added.
2 short blink: User commands (Table C) – when Strips is not added.
1 long blink: Acknowledges first a completed user command and then the successful transmission of it.
5 or 10 short blink: Error (E.g. communication with controller failed)
Communication to a Sleeping device (Wakeup)
This device is battery operated and turned into deep sleep state most of the
time
to save battery life time. Communication with the device is limited. In order
to
communicate with the device, a static controller C is needed in the
network.
This controller will maintain a mailbox for the battery operated devices and
store
commands that can not be received during deep sleep state. Without such a
controller,
communication may become impossible and/or the battery life time is
significantly
decreased.
This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the
desired
wakeup interval and the node ID of the controller. If the device was included
by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please
perform
the following action:
Wake up Strips manually for Z-Wave communication. Move the magnet to the rounded” edge, and once the LED blinks, move the magnet away (See figure below). Repeat two” more times within 10 seconds. A successful wake-up is confirmed with one LED blink.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 1 | Z-Wave Plus Lifeline |
---|
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 2: LED alarm event reporting
__
Size: 1 Byte, Default Value: 1
SettingDescription
0 | Off |
---|---|
1 | On |
Parameter 3: Temperature & Light reporting frequency
__
Size: 1 Byte, Default Value: 1
SettingDescription
1 | Normal |
---|---|
2 | Frequent |
Parameter 4: Temperature reporting
(Does not affect temperature alarms)
Size: 1 Byte, Default Value: 1
SettingDescription
0 | Off |
---|---|
1 | On |
Parameter 5: Temperature reporting unit
__
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Celsius |
---|---|
1 | Fahrenheit |
Parameter 6: Temperature alarms
__
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Off |
---|---|
1 | On |
Parameter 7: High temperature alarm level
__
Size: 1 Byte, Default Value: 60
SettingDescription
0 – 60 | Value in “°C (0 – 60″°C) |
---|---|
236 – 255 | Value in “°C (-20 – -1) |
Parameter 8: Low temperature alarm level
__
Size: 1 Byte, Default Value: 236
SettingDescription
0 – 60 | Value in “°C (0 – 60″°C) |
---|---|
236 – 255 | Value in “°C (-20 – -1) |
Parameter 9: Ambient light reporting
__
Size: 1 Byte, Default Value: 1
SettingDescription
0 | Off |
---|---|
1 | On |
2 | Report only when levels defined in parameter 10 & 11 are passed. |
Parameter 10: High ambient light report level
__
Size: 4 Byte, Default Value: 40000
SettingDescription
3 – 64 000 | Value in LUX |
---|
Parameter 11: Low ambient light report level
(Must be significantly lower than parameter 10)
Size: 4 Byte, Default Value: 5000
SettingDescription
1 – 42000 | Value in LUX |
---|
Technical Data
Dimensions | 15 x 195 x 6 mm |
---|---|
Weight | 10 gr |
Hardware Platform | ZM5101 |
EAN | 7350088520086 |
IP Class | IP 65 |
Battery Type | 1 * Lithium |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-18015953 |
Z-Wave Product Id | 0x019A.0x0003.0x0003 |
Frequency | Europe – 868,4 Mhz |
Maximum transmission power | 5 mW |
Supported Command Classes
- Association Group Information
- Association V2
- Battery
- Configuration
- Device Reset Locally
- Manufacturer Specific
- Notification V4
- Powerlevel
- Sensor Binary
- Version V2
- Wake Up V2
- Zwaveplus Info V2
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.