KERUI SP862 Wireless Solar Motion Sensor Kit
Wireless Solar Motion Sensor Kit User Manual
Product Introduction
STECH RO wireless solar driveway alarm uses digital dual-core fuzzy logic infrared control processing technology and intelligent analysis algorithms to effectively distinguish interference signals from human movement signals to prevent false alarms. It’s power saving, safety, environmentally-friendly, and easy-installed.create an expendable safe perimeter anywhere is ideal for homes,worksites,businesses,or the properties with no fencing
Package List
Receiver(hub),Sensor,Sensor base, User Manual, Warranty Card, Screws.DC Adapter(SV@SOOmh)
Features
- solar power support
- 2000mah rechargeable Lithium battery back-up
- 4 detecting zone 8 pairing sensor
- 5 adjustable volume
-
- 4 alarm mode(defense zone sound/music+partition voice/alarm voice/mute mode
Operating Instructions
Select ringtone and turn on/off Hub
- Short press: select the host voice (three kinds of voices: defense zone sound, music + partition voice, alarm voice;)
- Long press : Turn on and turn off the host.
- Turn on : 4 LED indicators flash quickly 2 times with 2 beeps.
- Turn off: 4 LED indicators flash quickly once with 1 beep.
Setting the Volume
Matching zone 2
- Long press. host beeps “one”
- Short press 1 time. host beeps “two”
- Wave hand to sensor window until host beeps”DIDl”twice Zone 2 matching actived.
Matching zone 3
- Long press. host beeps “one”
- Short press 2 times, host beeps “three”
- Wave hand to sensor window until host beeps “DIDl”twice Zone 3 matching actived.
Matching zone 4
- Long press. host beeps r’one”
- Short press 3 times. host beeps “four”
- Wave hand to sensor window until host beeps”DIDl”wice Zone 4 matching actived.
Delete Matching sensor on each zone
Delete Zone 1
- Long press setting button, host beeps “one”(blue led indicate zone 1)
- Long press setting button, host beeps”DiDiDiDi”,Done!
Delete Zone 2
- Long press setting button. host beeps “one”(blue led indicate zone 1)
- Short press setting button once, host beeps “two”, blue led indicate zone 2
- Long press setting button. host beeps”DiDiDiDi”, Done!
Delete Zone 3
- Long press setting button. host beeps “one”(blue led indicate zone 1)
- Short press setting button twice, host beeps “three”,blue led indicate zone 3
- Long press setting button, host beeps”DiDiDiDi”,Done!
Delete Zone 4
- Long press setting button, host beeps “one”(blue led indicate zone 1)
- Short press setting button three times. host beeps “four”.blue led indicate zone 4
- Long press setting button. host beeps”DiDiDiDi”, Done!
Note: Only two PIRS can be paired in each defense zone of the host; the host will drop out the pairing state without any operation in the 205 when the host is paired with the detector.
Note: The host has a voice prompt when the detector is triggered. After the voice prompt ends. the indicator light of the defense zone will remain on for a long time to remind the user that someone has triggered the detector in the area.
Reset: delete all sensors from host
- Press and hold when power off
- Put on 3XAA battery (before power on keep step l)host will continue beep and flash 10 times and zone 1 flash quickly
- Reset done!
Installation for sensor
- Tighten the large screw until sensor stays in place when repositioned.
- Mount sensor horizontally on solid surface 3-5 feet(l-1.Sm)
- Rotate/swivel sensor to adjust the ideal direction
2-Level Sensitive Adjustment
- Find the working button on swich off and on.
- Chose your ideal detecting sensitivity Note: This adjustment need to open the sensor, The ON and OFF of switch 1 is to decide whether to turn on the LED and flash once when the detector detects a person or a vehicle passes by.
Low battery reminder
The host power prompt
The host announces “Low Battery” when the battery voltage is lower than the
specified value, after the host enters a semi-sleep state. The host announces
“Low Battery” when the host triggers a key on the host. this state reminds the
user to replace the battery or use USB power supply.
The detector power prompt
The LED flashes three times when the battery voltage is lower than the
specified value, low voltage prompt, use USB-5V to charge or replace the
battery ASAP.
Technical parameter
Technical parameters of the host
- Working voltage: external USB-SV DC power supply / 3XAA
- Battery Shutdown current : <140uA
- Standby current: <13mA
- Working current : <200mA
- Recelv1ng frequency: 433MHz (FSK)
- Receiving distance: 2000ft/600m (open space)
Technical parameters of PIR
- Working voltage: USB-SV / 3.7V 2000mAh
- rechargeable lithium battery (built-in battery)
- Quiescent current: <.25uA
- Alarm current: <.45mA
- Charging current : <.400mA
- Battery life : 1 year
- Detection interval: 5s
- Detection distance: 20-40ft (6/12m)
- Detection angle: 90 degrees
- Working temperature :14~122 F/ -10 “C ~ + 50 “C
- Outdoor use: outdoor rainproof (IPV44)
- Ambient temperature: maximum 95% RH (no condensation)
- Installation height: 3.2-6.Sft/1-2m (vehicle),6.5-13ft/2-4m (human body)
- Transmission frequency : 433MHz (FSK)
- Launch distance: open distance is not less than 2000ft/600m
Note:
Keep host away from metal objects. Do not mount PIR motion sensor in direct
sunlight, near moving tree branches, or in the path of sprinkler system.
Ensure host is in clearest possible sight of the PIR motion sensor. The less
objects between the devices, the longer the range. If you have product issue
or want to activate the validity pis contact us for service
E-mail:stechro@stechroservice.com
FCC Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
To assure continued compliance, any changes or modifications not expressly
approved by the party. Responsible for compliance could void the user’s
authority to operate this equipment. (Example- use only shielded interface
cables when connecting to computer or peripheral devices).
This equipment complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
FCC Radiation Exposure Statement:
The equipment complies with FCC Radiation exposure limits set forth for
uncontrolled enviroment. This equipment should be installed and operated with