SHENZHEN MICROTOLE TECHNOLOGY CO W1A Digital Microscope Instruction Manual
- June 8, 2024
- SHENZHEN MICROTOLE TECHNOLOGY CO
Table of Contents
- SHENZHEN MICROTOLE TECHNOLOGY CO W1A Digital Microscope
- Product Overview
- Use Instructions
- Charging Instructions
- Microscope Opening and Use
- Accessories and Tools
- The APP Use Guide
- Troubleshoot the Microscope
- Microscopy Overall Parameters
- Digital Microscope
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SHENZHEN MICROTOLE TECHNOLOGY CO W1A Digital Microscope
Please read this manual in detail ! Careful reading experience is better!
Please keep the user instruction manual properly!
Product Overview
Please read this manual carefully before using.
Do not use the microscope until you know the method.
Use Instructions
- Please read this instruction manual carefully, and use it correctly.
- Pay attention to protect the lens part.Close the lens lid after using to avoid entering dust or strange objects.
- The microscope can be used in hand or inserted as a desktop, with attention to avoid damage to the components.
- When placing items, place them directly below the center of the lens as much as possible. a void not seeing objects clearly and bringing about a bad experience.
Instructions for Using the Microscope Installation
Microscopy Composition
Using Environment
- Please be at-10°C~45″C,Use under the environment
- Please avoid the microscope being wet with water, drinks,corrosive lamp liquid
- Please avoid keeping the microscope close to the heat source, open flame, flammable and explosive gases (liquid)
- Please avoid the dust from entering Microscope lens and interior
- Please avoid microscope Impact and violent shaking
At low temperatures, the available capacity of the battery decreases to varying degrees.
Charging Instructions
- When the microscope unit power is low, the power indicator light blue light flash.
- The red light is always on when charging, and the indicator light goes oft when tilling it up.
- You can use a daily mobile phone charger, computer, and charger to charge the microscope.
- The charging time should not exceed 12 hours to avoid affecting the battery life.
- During the charging process, it the microscope shell and the battery are slightly heated, please rest assured to use the normal phenomenon.
Storage Environment
Store it in a cool and dry place for daily use to avoid direct Sunlight.
Avoid storing the microscope in a place with the risk of falling,which may
cause the deviation of the microscope lens inside or the damage to other
components, and other irreparable damage problems.
Microscope Opening and Use
The Microscope is On and Off
Press the boot button on the side for 3 seconds,the small light on the USB
interface or the bottom light is on,It means that the microscope is already
turned on. Press and hold the boot button on the side for 3 seconds, USB, the
small light on the interface side is off or the bottom light is off, which
means that the microscope has been off. (Note: the microscopemonomer is
closed, suspended after use, do not forget to cover the lens cover.)
Microscopic Magnification Regulation
- Counter-Clockwise Rotation: multiple magnification
- Clockwise Rotation: multiple reduction
( Note: In case of any other problems, the reset hole will restore the factory setting. At the same distance, the rotating zoom cylinder has two magniations. To adjust more multiples, it can be adjusted up and down through the microscope base bracket.)
Accessories and Tools
The APP Use Guide
Use on Android /10S Devices:
- Scan the QR code, click download and install. Software to download the QR code
- The mobile terminal is the 1OS system, and you can search for ” Uni Lab” at APP Store for download
The lOS/ Android APP Icon
Turn On the Device
Long press the power button for 3s, and the blue light flashes under the button atter turning on, indicating that the app has not been connected yet.
-
Connect the Microscope to the Android /1OS Device
Opens the Uni Lab APP, click WiFi, jump to the connection page of the Android / lOS device, select the corresponding WiFi name of the product “WTM-1-XXXXXX” (hotspot without encryption) -
Clicks on and connects to the hotspot. It the connection contirmation prompt appears, please click “Keep Connected” (Android version) click “OK”
-
After the connection is successful the microscope blue lights on, proving that the microscope has suCcesstully connected to your device.
Return to the APP to use it only.
Note: Please open the phone/ tablet location permission when the APP is connected to the microscope.
Introduction and Use of the APP Interface
Open the APP, and follow the indicated operation steps.
(Select the content in the red box)
-
APP, Reading Interface
Because of the mobile phone model version is different, the pictures are for reference only- Take a photo: Select a photo mode
- Recording: Select the recording mode
- Zoom in: Click to zoom in on the screen (use when the screen is too small)
- Zoom Out: Click to zoom out the screen (used when the screen is too large, the default is the smallest each time it is opened)
The Computer Interface Introduction and Use
- When the computer operating system is Windows 10 or higher, search in the Microsoft Store Download “Uni Lab” , (as shown in “ “); when the computer system is Mac, please use the computer to Watch with a camera (as shown in ” “). The device camera button cannot be used,it can only be realized through software Photo recording function;
- Windows 7 and Windows XP system,please download the software from the following website”http://www.weetool.net”
- Log in the website and download UniLab software.
- Open the software and select the device. (Windows
- Open the software and select the device. (Mac)
Troubleshoot the Microscope
Note: It is normal for the APP to exit after being plugged in.
Microscopy Overall Parameters
Digital Microscope
-
Product name: Digital Microscope
-
Product size: 125x95x55mm
-
Net weight: about 0.29kg
-
Power supply mode: 700mAh
-
Input parameter: DC5V=
-
Operating temperature: -10°C~45°C
-
Wireless connection: Wi-FilEEE802.1
1b/g/n2.4Ghz -
Certification information: CE FCC RoHS
Microscopy Overall Parameters
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirement. The device can be u sed in portable exposure condition without restriction
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>