Miele PFD 104 SCVi XXL Fully Integrated XXL Dishwasher Instruction Manual
- June 4, 2024
- Miele
Table of Contents
PFD 101 U
PFD 102 i
PFD 104 SCVi
Installation plan
Installation notes
For safe installation and commissioning of the dishwasher please read the
installation plan, the service documentation, the installation diagram, and
the operating instructions.
This installation plan includes the dimensions of the appliance, the technical
data, and the requirements to be met on-site for the installation of the
dishwasher.
Installation requirements
Installation and commissioning work should be performed by a qualified and
trained service technician in accordance with local and national safety
regulations.
Installation must comply with all local codes and regulations.
Surrounding area Condensate can build up in the area surrounding the
dishwasher. Any cabinetry and fittings in the room must, therefore, be
suitable for this purpose.
Vapor-barrier film for built-in appliances
The vapor-barrier film supplied with the dishwasher protects the countertop
from damage caused by steam when the door is opened. Attach the vapor-barrier
film above the door, underneath the countertop.
Electrical connection
All work on the electrical connection should be carried out by Miele Customer
Service, an authorized Miele dealer, or a qualified electrician.
Plug Connection
The dishwasher should be connected to the electricity supply via an electrical
outlet.
Hard-wired
If the dishwasher is hard-wired to the power supply, a circuit breaker capable
of disconnecting the dishwasher at all poles must be installed on-site. This
power switch must have a contact gap of at least 1/8″ (3 mm). The electrical
socket outlet and the circuit breaker must be accessible after the appliance
has been installed. This is to enable an electrical safety test to be carried
out after installation and after any servicing work. The power cord must be
laid protected from the risk of thermal damage.
Equipotential bonding and grounding
This machine must be grounded in accordance with local code.
Water connection
Before connecting the dishwasher or immediately following a disruption in
water supply the water supply pipe must be vented from air pockets to avoid
pressure surges that may destroy components in the dishwasher.
Water intake
The quality of the incoming water must comply with the requirements for
drinking water in the country in which the dishwasher is being operated. The
dishwasher must be connected to the water supply in strict accordance with
current local and national water authority regulations. It can be connected to
cold or hot water supplies. Connecting the dishwasher to a hot water supply
will reduce program cycle times. For short program cycle times, the water
pressure of at least 29 psi (200 kPa) is also required.
If this type of shut-off valve is not available, only a qualified installer
may connect the dishwasher to the domestic water supply. The shut-off valve
should remain accessible once the dishwasher has been installed so that the
water supply can be shut off whenever the appliance is not in use.
Drainage
The dishwasher drainage hose should be connected to a separate on-site drain
for the dishwasher only. If no separate drain is available, we recommend
connecting it to a dual-chamber siphon. When using a drain loop additional
backflow prevention is not required. If the hose is to be directly connected
to the drainage outlet on-site, use the hose clip supplied with the
dishwasher. The on-site connector for the drain hose can be used for various
hose diameters. If the connector extends more than 1″ (30 mm) into the drain
hose, it must be shortened. Otherwise, the drain hose can become clogged.
Lay the drain hose so that it does not kink and is not being subjected to
pressure or tugged.
If the on-site drain connection is situated lower than the guide path for the
lower basket rollers in the open door, a siphoning effect during a program can
cause the appliance to empty itself of water. In this case, lay the drain hose
with a bend in it so that its highest point is at least level with the guide
path for the lower basket rollers.
Appliance dimensions and installation dimensions
Undercounter appliance
PFD 101 U
Built-in appliance
PFD 102 i
Front panel dimensions
Length | 19.7″–25.7″ | 500–654 mm |
---|---|---|
Thickness | 0.63″–0.79″ | 16–20 mm |
Weight | 8.8–24.3 Ibs | 4–11 kg |
Fully integrated appliance
PFD 104 SCVi
Front panel dimensions
Length | 27.2″–31.9″ | 690–810 mm |
---|---|---|
Thickness | 0.63″–0.79″ | 16–20 mm |
Weight | 11–26.5 lbs | 5–12 kg |
Connections on the back of the appliance
- Electrical connection
- Equipotential bonding and grounding
- Wastewater
- Cold or hot water
Technical details
Dimensions and weights
| | PFD 101 U| PFD 102 i| PFD 104 Vi
---|---|---|---|---
Height| [inches] [mm]| 31.7
805| 31.7
805| 33.3
845
Height adjustment| [inches] [mm]| 2.56
65| 2.56
65| 2.56
65
Width| [inches] [mm]| 23.5
598| 23.5
598| 23.5
598
Depth| [inches] [mm]| 22.4
570| 22.4
570| 22.4
570
Depth with door open| [inches] [mm]| 45.9
1165| 45.9
1165| 47.4
1205
Max. toe-kick return| [inches] [mm]| 4.53
115| 4.53
115| 4.53
115
Weight| [ibs] [kg]| 97
44| 92.6
42| 112
51
Max. floor load| [N]| 1000| 1000| 1000
Emission levels| | PFD 101 U| PFD 102 i P| FD 104 Vi
Sound power level| [dB(A)
re 1
pW]| 48| 48| 45
The sound pressure level in the workplace| [dB(A)]| 35.1| 35.1| 31.4
Electrical connection the USA
PFD 101 U
| Standard electrical
connection| Possible voltage
**variant*
---|---|---
Voltage| AC 120 V| 2N AC 120/208-240 V
Frequency| 60 Hz| 60 Hz
Fuse rating| 15 A| 2 x 30 A
Plug| 5-15P NEMA| 14-30P NEMA
Power cord length| 5.6 ft/1.7 m| 5.6 ft/1.7 m
Power cord cross-section| 3 x AWG14| 4 x AWG10
Heat output| 1.3 kW| 3.5-3.8 kW
Total rated load| 1.4 kW| 3.7-4 kW
‘ The conversion can be done by Miele Service.
PFD 102 i and PFD 104 SCVi| |
| Variant 1| Variant 2**
Voltage| AC 120 V| 2N AC 120/208-240 V
Frequency| 60 Hz| 60 Hz
Fuse rating| 15 A| 2 x 30 A
Plug| 5-15P NEMA| 14-30P NEMA
Power cord length| 5.6 ft/1.7 m| 5.6 ft/1.7 m
Power cord cross-section| 3 x AWG14| 4 x AWG10
Heat output| 1.3 kW| 3.5-3.8 kW
Total rated load| 1.4 kW| 3.7-4 kW
Electrical connection Canada
PFD 101 U
| Standard electrical
connection| Possible voltage
variant
---|---|---
Voltage| AC 120 V| 2N AC 120/208-240 V
Frequency| 60 Hz| 60 Hz
Fuse rating| 15 A| 2 x 30 A
Plug| 5-15P NEMA| 14-30P NEMA
Power cord length| 5.6 ft/1.7 m| 5.6 fV1.7 m
Power cord cross-section| 3 x AWG14| 4 x AWG10
Heat output| 1.3 kW| 3.5-3.8 kW
Total rated load| 1.4 kW| 3.7-4 kW
The conversion can be done by Miele Service.
PFD 102 i| |
| Variant 1| Variant 2
Voltage| 2N AC 120/208-240 V| AC 120 V
Frequency| 60 Hz| 60 Hz
Fuse rating| 2 x 30 A| 15 A
Plug| 14-30P NEMA| 5-15P NEMA
Power cord length| 5.6 ft/1.7 m| 5.6 ft/1.7 m
Power cord cross-section| 4 x AWG10| 3 x AWG14
Heat output| 3.5-3.8 kW| 1.3 kW
Total rated load| 3.7-4 kW| 1.4 kW
?FD 104 SCVi| |
| Standard electrical
connection| Possible voltage
variant
Voltage| 2N AC 120/208-240 V| AC 120 V
Frequency| 60 Hz| 60 Hz
Fuse rating| 2 x30 A| 15 A
Plug| 14-30P NEMA| 5-15P NEMA
Power cord length| 5.6 ft/1.7 m| 5.6 ft/1.7 m
Power cord cross-section| 4 x AWG10| 3 x AWG14
Heat output| 3.5-3.8 kW| 1.3 kW
Total rated load| 3.7-4 kW| 1.4 kW
Water intake
Max. water temperature | 140 °F 60 °C |
---|---|
Max. water hardness | 6.5 mmoV1 |
Max. water hardness | 37.5 gr/gal |
Water connection pressure | 5 – 1000 kPa |
On-site threaded connection (flat seal) | 3/4″ Hose thread |
Connection hose length | 4.9 ft 1.5 m |
Connection hose extension | 4.9 ft 1.5 m |
Optional accessory
Drainage|
Max. water temperature| 180 °F| 82 °C
Drain hose length| 4.9 ft| 1.5 m
Max. drain hose length| 13 ft| 4 m
Max. drain height| 3.3 ft| 1 m
Max. transient flow rate| 10 I/min|
Hose inner diameter| 0.87″| 22 mm
On-site hose sleeve (0 x length)| 0.87″ x 1.18″| 22 x 30 mm
Operating conditions|
Ambient temperature| +41 – +104 °F| +5 – +40 °C
Relative humidity:
Up to 88 °F (31 °C), maximum Linear decreasing to 104 °F (40 °C)| 80 %
50 %|
Max. altitude above sea level up to| 13,123 ft| 4,000 m
Storage and transportation conditions|
Ambient temperature| -4 – +140 °F -20 – +60 °C
Relative humidity| 10-85 %
Air pressure| 500-1060 hPa
Min. site access dimensions including| | transport pallet|
Height| 38.2′| 970 mm
Width| 26.4″| 670 mm
Depth| 26.4′| 670 mm
Please have the model and a serial number of your machine available when contacting Technical Service.
U.S.A.
Miele, Inc.
National Headquarters
9 Independence Way
Princeton, NJ 08540
Phone: 800-991-9380
www.mieleusa.com/professional
prosales@mieleusa.com
Technical Service & Support
Phone: 800-991-9380
proservice@mieleusa.com
Manufacturer | Fabricant: Miele & Cie. KG
Carl-Miele-Straße 29, 33332 Gütersloh, Germany | Allemagne
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>