VENEZIA LB180 Woodbridge Whirlpool Tub and Air Bathtub Installation Guide

June 9, 2024
VENEZIA

VENEZIA-LB180-Woodbridge-Whirlpool-Tub-and-Air-Bathtub-Installation-
Guide-logo VENEZIA LB180 Woodbridge Whirlpool Tub and Air Bathtub

VENEZIA-LB180-Woodbridge-Whirlpool-Tub-and-Air-Bathtub-Installation-Guide-
product

Certified to the following Codes & Standards

  •  U.S Safety Standard: UL 1795 – Hydro massage Bathtubs (UL)
  •  ASME A112.19.7 / CSA B45.10-2012(R17) – Hydromassage Bathtub Systems
  •  CSA B45.5/IAPMO Z124-2017 – Plastic Plumbing Fixtures
  •  2009 and 2006 International Plumbing Code® (IPC)
  •  2021, and 2006 International Residential Code® (IRC)
  •  2018, 2015, and 2006 Uniform Plumbing Code® (UPC)

READ ALL INSTRUCTIONS BEFORE UNPACKING THE PRODUCT INSTRUCTIONS THAT, IF IGNORED COULD RESULT IN DEATH OR SERIOUS INJURY CAUSED BY INCORRECT HANDLING OR INSTALLATION OF THE PRODUCT. THESE INSTRUCTIONS MUST BE OBSERVED FOR SAFE INSTALLATION.2 PEOPLE ARE REQUIRED TO LIFT AND DURING THE ENTIRE INSTALLATION OF THIS PRODUCT

This product must be installed by a fully insured and licensed plumber only. Installaon of any of our products by anyone other than a fully insured and licensed plumber shall void the limited warranty. We recommend that such a licensed plumber has experience in the installaon of products.

The limited warranty is void on any commercial installaon
We are not responsible for local code compliance for this product. Building and plumbing codes may vary from state to state in accordance with your location. We are not responsible for providing any compliance ceficaons. Under no circumstances we shall not be liable for any incidental damages sustained in connection with this product Neither manufacturer, distributor, nor retailer is responsible for water damage or flood caused due to the use of this product. Under no circumstances We shall not be liable for any and all fees, cost of installaon/reinstallation/removal, subsequent damage or transportation in case of the product defect

BEFORE YOU BEGIN

  • Please read these instructions carefully to familiarize yourself with the required tools, materials, and installaon sequences. Follow the sections that pertain to your particular installaon. This will help you avoid costly mistakes. In addition to proper installaon, read all operating and safety instructions.
  •  All informaon is based on the latest product informaon available at me of publication. WOODBRIDGE® reserves the right to make changes in product characteristics, packaging, or availability at any me without notice.

PRODUCT REQUIREMENTS

  • Summary Of Key Requirements
    Observe all local plumbing codes, Install the unit to a level subfloor, and Provide properly -dimensioned framing.

  • Product Inspection
    Uncrate and inspect the bath for damage. Leave all materials in the crate during construction to prevent damage.

ROUGHING-IN

VENEZIA-LB180-Woodbridge-Whirlpool-Tub-and-Air-Bathtub-
Installation-Guide-fig-1

IMPORTANT INFORMATION

  •  Measurements are ± 1/2″ and subject to change without notice
  •  Specificaons & Configuraons are subject to change without notice
  •  Please measure the tub on-site before installaon
  •  Please note that installer(s) must be cerfied or the warranty will be voided.
  •  Measurements herein supersede all others published prior to the publication date shown below
  •  Before ordering or installing, please consider future access to equipment

INSTALLATION REQUIREMENTS

Tools Required

  •  Adjustable pipe
  •  wrench
  •  Ruler
  •  Level
  •  Safety shoes
  •  Safety glasses
  •  Square
  •  Screwdriver
  •  Pliers
  •  Utility knife

Materials Required

  •  Plumbers puy
  •  Wall coverings, as necessary
  •  Silicone sealant
  •  Gypsum cement (optional)
  •  Construction adhesive
  •  (optional)
  •  Protective covering for
  •  bathtub
  •  Nails

Clearance Requirements
Check the rough-in and room dimensions to provide adequate space for the bath unit.

SITE REQUIREMENTS

Plumbing Preparation
Position the plumbing according to rough-in dimensions. Cap the supplies and check for leaks.

BEFORE INSTALLING UNIT

CAUTION : Ensure a watertight seal on the bath drain connections.

  • Install the faucet valves and shower head tee. When drilling the bathtub for a faucet, ensure sufficient clearance. Open the hot and cold water valves and check the supply connections for leaks.
  •  Run water into the bath and check the drain connection for leaks.
  • Fill the bathtub up to the overflow level and check the overflow unit for leaks.

INSTALL BATHTUB

This product must be installed by a fully insured and licensed plumber only.

  1. Your new bathtub has been manufactured to the highest possible standards, it has been tested and approved by the factory

  2. When removing the bathtub from the protective carton. DO NOT LIFT THE BATHTUB BY PIPE WORK. Inspect for any possible damage that may have occurred in transit.
    IMPORTANT: Bathtub must be installed level on all top edges.

  3. Set the bathtub on two 4×4 pieces of lumber .so you can access it from the boom of the bathtub.

  4. Connect Power Supply: Connect the power supply to the control unit. The electrical connections must comply with local authority regulations and must be done by an authorized electrician.

  5. Fill the bathtub with water to approximately 40 mm(1.6˝) above the jets and trial run the pump for 10- 15 minutes. Check all the fings for leaks and test the control functions. Switch off the spa pump and leave the unit filled with water (the pump is not running) for at least another two minutes. Check the pump and pipe union connections for leaks. Hand-tighten union connections if required.

  6. The unit must be connected only to a supply circuit that is protected by a Ground-Fault Circuit Interrupter (GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis.

ELECTRICAL REQUIREMENTS

120V 15AMP Dedicated GFCI Breaker

In the example above, there are 1 Dedicated 15AMP 110V GFCI Breakers.

  1. One (1) Dedicated GFCI Breaker for the Air Massage Blower Each Accessory Requires a Dedicated 120V 15AMP GFCI Breaker.

THESE CAN NOT BE SHARED
(LED LIGHTS & OZONE CAN SHARE A BREAKER)

AIR MASSAGE, WHIRLPOOL PUMP

For Air Bath and Whirpool Tub installation, Do not apply any silicone sealant after installation, leave a 5-10mm(0.2″ to 0.4″)gap for motor/pump ventilation purposes.

In the example above, there are 2 Dedicated 15AMP 110V GFCI Breakers.

  1.  One (1) Dedicated GFCI Breaker for the Whirlpool Pump
  2.  One (1) Dedicated GFCI Breaker for the Air Massage Blower

Each Accessory Requires a Dedicated 120V 15AMP GFCI Breaker. THESE CAN NOT BE SHARED (LED LIGHTS & OZONE CAN SHARE A BREAKER)

WARRANTY

Woodbridge warrants its products as listed in below to be free of material and workmanship defects, subject to the limitations set forth in this limited warranty.

  •  Bathtub, Whirlpool/Air Bubble Massage Tub: 1 Year limited to be free of defects in material and workmanship
  •  Toilet and Bidet: 1 Year limited to be free of defects in material and workmanship
  •  Faucet: 1 Year limited to be free of defects in material and workmanship
  •  Vanity: 1 Year limited to be free of defects in material and workmanship
  •  Granite, Marble, Engineered Quartz Vanity Top: 1 Year limited to be free of defects in material and workmanship
  •  Medicine Cabinet, LED Mirror: 1 Year limited to be free of defects in material and workmanship
  •  Stainless Steel Sink: 1 Year limited to be free of defects in material and workmanship
  •  Solid Surface Shower Wall Panel, Shower Base, and Vanity Top: 10 Years limited warranty to be free from material defects
  •  Shower Door: Lifetime warranty on glass components and 1Year limited on other hardware
  • This limited warranty is non-transferable and only applies to products purchased and installed in the United States.

This limited warranty excludes all industrial, commercial, and business usage. Proof of purchase (original sales receipt) from the original purchaser, Description, and pictures of the defect, model number, or model description must be provided to Woodbridge Bath for all warranty claims and Woodbridge Bath IS NOT responsible for labor cost, removal, or installaon costs. This limited warranty shall not apply to goods that have been subject to accident, negligence, improper installaon, product abuse, product misuse, or use of cleaners containing abrasives, alcohol, or other organic solvents, whether performed by a contractor, service company, or yourself, are excluded from this warranty.

This warranty does not cover surface damage caused by the use of chemicals that break through or dissolve the surface finish or damage caused by the accidental dropping of sharp or heavy objects. Improper care and use of abrasive cleaners will void the warranty.
During this limited warranty period if a malfuncon occurs and are inspection it is determined that a defect developed during normal use, Woodbridge will as at its election proceed with any of the following options:

  1.  repair or replace the defective part(s) or product(s) at cost
  2. issue a refund of the original purchase price of the product(s) (Valid within 30 days from the date of purchase)
  3.  issue a credit to be applied toward the purchase of a new product. Shipping/delivery charges may apply and are in sole discretion.

Caution
NEVER use cleaners containing abrasive cleaners, ammonia, bleach, acids, waxes, alcohol, solvents, or other products that are not recommended for Chrome finish will void the warranty. Woodbridge products should be installed by a fully insured and licensed contractor only. Installaon by anyone other than a fully insured and licensed contractor will void this limited warranty.

RESPONSIBILITIES OF OTHERS
Inspecting the unit prior to installaon is the responsibility of the installer or building contractor who acts on behalf of the user. They are responsible for ensuring the unit is free of defects or damage. Noces is placed on the unit and on the shipping carton advising the installer of this responsibility. In the event of a problem, the unit must not be installed. Woodbridge is not responsible for failures or damage that could have been discovered, repaired, or avoided by proper inspection and testing prior to installaon.
Damage occurring in transit is the responsibility of the carrier.

The user or installer MUST open the crate and inspect the unit for damage when it is delivered. If damage is discovered, it must be reported immediately to the seller and the carrier in wring, and an inspection is requested. Failure of the carrier to respond should be reported to the seller and the carrier. Your freight claims should be filed promptly thereafter.

This limited warranty does not cover any liability for consequential or incidental damages, all of which are hereby expressly disclaimed, or the extension beyond the duration of this limited warranty of any implied limited warranties, including those of merchantability or fitness for an intended purpose.

DISCLAIMER
Except as expressly provided, there shall be no warranty or obligation, express or implied, oral or statutory. No dealer or other person has the authority to make any warranties or representations concerning its products. In no event shall be held responsible for any such warranties or representations.

Some states/provinces do not allow limitations on how long an implied warranty lasts, or the exclusion on limitation of special, incidental, or consequential damages, so these limitations and exclusions may not apply to you. This warranty gives you specific legal rights, you may also have other rights which vary from state/province to state/province. To obtain warranty and replacement parts, please send an e-mail to [email protected] with the original receipt informaon, Woodbridge will determine whether to repair or replace your product, issue a refund or issue a credit.

IMPORTANT SAFETY RULES

  • The bathtub must be installed and used as described in this manual
  • Use caution when entering or exing the bathtub
  • Do not permit children or persons with infirmies to use the bathtub without the supervision of an adult
  • People using any medications or having adverse medical history must consult a physician prior to use of the bathtub to avoid potential hyperthermia and possible drowning
  • Water temperatures over 100ºF may cause hyperthermia and/or other health problems. Check the water temperature and adjust it for your personal comfort
  • Never use a bathtub while intoxicated, or taking meals or any alcoholic beverages. Consuming alcoholic beverages before or during bathing will cause drowsiness and may result in hyperthermia, loss of consciousness, or even drowning
  • If you are pregnant or you feel that you may be pregnant, consult your doctor before using the bathtub
  • Never use any electrical devices such as a hair dryer, lamp, telephone, tv, radio, or others within 5 feet of the bathtub
  • Do not overfill the bathtub before entering. Entering the bathtub when filled will cause overflow and slippery conditions. Use extreme caution when entering and exing

Care and Cleaning

  •  Most dirt will wash off with mild soap and warm water.
  •  For tough spots, use liquid dishwashing soap or non-chlorine bleach.
  •  Do not use abrasive material such as steel wool or scouring pads to clean the acrylic surface.
  •  Always test the cleaning solution on a small area before using it on the entire surface.
  •  Do not allow cleaning to soak on the acrylic surface.
  •  Rinse thoroughly with water immediately and wipe dry with so cloth.

Repair and Maintenance

  •  Use liquid polish compounds such as Gel-Gloss Kitchen and Bath Polish(TM) to keep the original shine of the acrylic surface.
  •  Light scratches can be removed with polishing compounds for automobiles.
  •  For deeper scratches use wet sandpaper (1500 grit or higher).
  • Always add water when sanding and lightly sand the area larger than the scratch in a circular moon to remove the scratches.
  • Repeat until the scratch is removed. Use so cloth and a small amount of polishing compound to restore shine. Repeat as needed until surface shine is restored.

IMPORTANT!
DO NOT USE Abrasive cleaners such as acid, ammonia, bleach, and similar solutions. Use of such solutions may cause corrosion, finish peeling, and/or dull the surface.

DO NOT USE Abrasive sponges or cloth. Never use steel, wool, or wire brushes that will permanently scratch the surface. Retain these installaon instructions for future reference! Thank you for using Woodbridge products! Please don’t hesitate to contact us if you have any questions or concerns. Customer Service Phone: 562-229-0088. (Monday – Friday 9 AM – 5 PM Pacific Time)
Or Email: [email protected]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

VENEZIA User Manuals