SIEMENS ECHS100 4.17-in Hub in the Breaker Box User Guide

June 2, 2024
SIEMENS

SIEMENS ECHS100 4.17-in Hub in the Breaker Box

Arc Fault Circuit Interrupters (AFCI)

Identifying applications:
Used in Siemens and Murray load centers

Definition of product:

Arc fault circuit interrupter (AFCI) uses advanced electronic technology to provide maximum available protection against the effects of arcing faults.

Overview of the product:
  • United States Fire Administration (USFA) reported:
    – Annually, an estimated 28,300 residential electrical fires cause 360 deaths, 1,000 injuries, and $995 million in direct loss.
    – 15% of residential electrical fires start in bedrooms.
    – 47% of residential electrical fires are caused by the wiring.

  • Combination Type AFCI’s are required by the 2005, 2008, 2011, 2014 and 2017 National Electric Code ®

Product rating: UL listed

General features and benefits:
  • 1 and 2 pole Combination Type AFCIs
  • Exclusive LED trip indicators indicate cause of last trip (ie. Arcing fault or overcurrent condition.)

1-Pole Combination Type AFCI

LED
indicator| Last known trip condition
ON| Arc fault
OFF| Overcurrent
2-Pole Combination Type AFCI

LED
indicator| Last known trip condition
Yellow 1| Yellow 2
On| OFF| Arc Fault (Leg A)
OFF| ON| Arc Fault (Leg B)
OFF| OFF| Overcurrent

Accessories
  • Padlocking device: ECPLD1

Arc Fault Breaker Catalog Numbering System

Q 1 20 AFC P
Brand name No. of Poles Amperes Special Applications

Packaging
Q = Siemens MP = Murray| 1 = 1
2 = 2| 15 = 15A
20 = 20A| (blank) = Standard breaker
AFC = Combination Type Arc Fault Circuit Interrupter| (blank) = cardboard packaging
P = Clamshell packaging for retail

Ground Fault Circuit Interrupters (GFCI)

Identifying applications:
Used in Siemens and Murray load centers

Definition of product:

Ground fault circuit interrupter (GFCI) is designed to protect against severe electrical shock or electrocution from ground faults. Ground faults occur when the electrical current in an appliance strays outside its normal path, and the human body becomes part of the path through which the electrical current may flow.

Overview of the product:

  • GFCIs are installed to protect areas of the home, such as the kitchen, bathroom or laundry, where electrical appliances or products may come into contact with water.
  • Current imbalances of 4-6 milliamps or more between load conductors will cause the ground fault sensor to trip the circuit breaker.

Product rating: UL listed, CSA Certified

General features and benefits:
  • Available in 1-pole (15-30A) and 2-pole (15-60A)
  • Common uses: spas, hot tubs, kitchens, bathrooms, garages, etc.
  • Resists false tripping (shielded to prevent RF interference)
  • Standard 1 inch per pole format with plug-in design
  • Provides Class A GFCI protection

Ground Fault Breaker Catalog Numbering System

Q F 1 20 P
Brand name Ground Fault Indication No. of Poles
Amperes Packaging

Q = Siemens
MP =
Murray| F = Ground Fault; 5mA personnel protection
E = Ground fault; 30mA equipment protection| 1 = 1
2 = 2| 15 = 15A
20 = 20A
30 = 30A
40 = 40A
50 = 50A
60 = 60A| (blank) = cardboard packaging
P =
Clamshell packaging for retail

Load centers PL and ES Series

Identifying applications:
Residential and multi-family electrical distribution

Definition of product:

A load center is the point where all of the electricity enters and is distributed throughout the house.

Overview of the product:
  • Copper Bus and Aluminum Bus variations
  • 100-225A, 1 and 3-phase, NEMA 1 and 3R
  • Main Lug and Main Breaker options

Product rating: UL listed

General features and benefits: PL Series
  • Copper Bus
  • Convertible from Main Lug to Main Breaker
  • 12-70 circuits/spaces
  • 2 Ground Bars factory installed
  • INSTA-WIRE™ neutrals and grounds
Catalog Numbering System

Siemens load centers meet or exceed the following standards.
  • UL50 – Electric Cabinets and Boxes
  • UL67 – Electric Panelboards
  • UL486 – Wire Connectors
  • UL489 – Molded-Case Circuit Breakers
  • UL869 – Service Equipment
  • UL943– Ground Fault interrupters (Class A – Personnel Protection)
  • Federal Specification W-P-115b – Panel Power Distribution
  • Federal Specification W-C-375B – Circuit Breakers
  • NEC
  • NEMA 250
Underwriters’ Laboratories, Inc. reference file numbers:
  • Series Connected Circuit Breaker Information is recognized by UL under file #E10848(N)
  • Load Centers Listed by UL under file #E10703
  • Load Centers UL recognized components found under file #E10703, Volume 6 and 7. (Also referenced under the recognized components directory – section QEUY2)
  • EQ Circuit Breakers are Listed by UL under file #E82615
Load center Accessories

Ground Bars:
2 included in all PL Series load center. Sold separately for ES Series.
EC2GB15, EC3GB27

Filler Plates:
Covers twist outs from a dead front without a breaker to fill the space.
ECQF3P

Hubs :
For use on outdoor load centers for water tight connection to conduit fittings.
ECHS000, ECHS075,
ECHS100, ECHS125,
ECHS150, ECHS200

QN and MPD

Identifying applications:
Used as a main breaker in small circuit load centers, circuit breaker enclosures, meter mains and meter combos. Used as a branch breaker to be a main disconnect for main lug only load centers.

Definition of product:

The QN is used as both a branch breaker and a main breaker in applications which require a two pole, 120/240V AC breaker.

Overview of the product:
  • 150, 175, and 200 A
  • 10k, 22K, 65K AIC

Product rating : UL listed

General features and benefits:
  • Available with a reverse handle mechanism
Accessories
  • Padlocking device ECQLN3

QN Breaker Catalog Numbering System

  QN 2 150 R H
Interrupting Rating Brand name No. of Poles
Amperes Handle operation Interrupting Rating

(blank) =

10kAIC

| QN =
Siemens| 2 = 2| 150 = 150A| (blank) =
vertical
applications| (blank) =
10kAIC
175  175A
200 = 200A
H = 65kAIC| MPD =
Murray|  | R =
horizontal
applications| H = 22kAIC

MBK Breaker

Identifying applications:
Used in Ultimate load centers, 1 phase PL and ES load centers, riser panel load centers, and generator ready load centers

Definition of product:

Main breaker used in various Siemens load centers

Overview of the product:
  • 2 Pole
  • 100, 125, 150, 200, 225 A
  • 22K AIC

Product rating : UL listed

General features and benefits:
  • 00 and 125A breakers have a smaller footprint than the 150A+ MBKs so they cannot be installed in 150A+ load centers for increased installation safety
Accessories
  • Padlocking device
    ECQLN3
Catalog numbers

Siemens :
MBK100A, MBK125A, MBK150A, MBK200A, MBK225A
Murray :
MBK100M, MBK125M, MBK150M, MBK200M, MBK225M

QP Breakers

Identifying applications:
Used as a 1” pole center branch breaker for applications that require plug-in (QP) or bolt-on (BL) connections

Definition of product:

1” pole center branch breaker

Overview of the product:
  • 1, 2, and 3 Poles (common trip)
  • Available as 120V, 120/240V, 240V AC
  • 10-125A
  • 10K, 22K, 65K AIC

Product rating : UL listed

General features and benefits:

  • Time saving INSTA-WIRE™ feature
Accessories
  • Padlocking device: ECPLD1, ECPLD2, ECPLD2R, ECPLD3, ECPLD3R, ECQLD3, ECQLD4, ECQTH4
  • Handle tie: ECQTH3
  • Mechanical interlock: ECQML12
  • Handle blocking device: ECQL1

Standard Breaker Catalog Numbering System

Q 1 20 H
Brand name No. of Poles Amperes Interrupting Rating

Q = Siemens plug-in
MP = Murray plug-in| 1 = 1
2 = 2
3 = 3| 10 = 10A
15 = 15A
20 = 20A
25 = 25A
30 = 30A
35 = 35A
40 = 40A
45 = 45A
50 = 50A
60 = 60A
70 = 70A
80 = 80A
90 = 90A
100 = 100A
110 = 110A
125 = 125A| (blank) = 10kAIC H =  22kAIC HH = 65kAIC

QT Breakers

Identifying applications:
Used as branch breakers in Siemens load centers

Definition of product:

1/2” pole centers branch breakers offered as a duplex, triplex, and quadplex.

Overview of the product:
  • 120/240V AC
  • Available as 120V, 120/240V, 240V AC
  • 10K AIC
  • 15-50A

Product rating: UL listed

General features and benefits:
  • Space saving design allows two poles to fit in a 1” panel space
  • Available without a rejection tab so it can be used with an unnotched stab (for panels built before the 1970s)
Accessories
  • Padlocking device: ECPLD1, ECPLD2, ECPLD2R, ECQLD4
  • Handle tie: ECQTH2
  • Handle blocking device: ECBX23IM

QT Breaker Catalog Numbering System

Q   15 15 NC
Brand name No. of Poles Amperes Amperes **Special

Application**
Q = Siemens| (blank) = Duplex| 15 = 15A| 15 = 15A| (blank) =
standard
 | 20 = 20A| 20 = 20A
25 = 25A
30 = 30A
35 = 35A
40 = 40A
45 = 45A
50 = 50A
MP = Murray| 2 = Triplex or
Quadplex| 30 = 30A| NC = Non
CTL for
replacement use only in panels
manufactured
before 1968.
CT = Triplex
CT2 = Quadplex

One Pole Applications

*These are typical installations. Check with local codes, existing wire size installed, and ratings of the appliances before proceeding.

Appliance Watts Voltage Amps Breaker
Dishwasher 1200 120 20 Q120
Lighting Fixture 1200 120 15 Q115
Refrigerator/ Freezer 300/350 120 20 Q120
TV/DVD 300 120 20 Q120
Washing Machine 1200 120 20 Q120
Waste Disposal 300 120 20 Q120

Two Pole Applications

Appliance Watts Voltage Amps Breaker
Built-in Oven 4500 120/240 30 Q230
Central Air 6000 120/240 50 Q250
Clothes Dryer 5000 120/240 30 Q230
Range 12000 120/240 50 Q250
Range Top 6000
3300 120/240 30

20

| Q230 Q220
Water Heater| 4000| 120/240| 30| Q230

Surge Protection Device

Identifying applications:
Provides surge protection for all branch circuits in the load center of the residence at no loss of load center spaces

Definition of product:

2” Wide plug-on containing two one pole circuit breakers and a surge arrester

Overview of the product:
  • Utilizes Siemens-built 150V AC, 40mm, metal oxide visitor with maximum impulse rating of 40 kA
  • Rated 120/240V AC

Product rating: UL listed

General features and benefits:
  • Easy to install and perfect for retrofit
  • LEDs provide protection status
  • $20,000 warranty for the residential electrical system (Load center, internal wiring, receptacles, dimmers, hard wired appliances)
  • Surge protection at no loss of load center spaces

Surge Protection Breaker Catalog Numbering System

QSA 20 20 SPD
Brand name Amperes Amperes Special Application
QSA = Siemens MSA = Murray 15 = 15A
20 = 20A 15 = 15A
20 = 20A SPD = Surge Protection Device

Breaker Accessories

Padlocking Device:

For locking breaker in “OFF” position. Note “ON” position does not affect breaker functionality.
ECPLD1, ECPLD2,
ECPLD2R, ECPLD3,
ECPLD3R, ECQLD3,
ECQLD4, ECQLN3,
ECQTH4
Available for: QP, BL, QT, QN, QNR, 150A+ MBK

Handle Tie:

Provides simultaneous switching of 2 adjacent handles
ECQTH2, ECQTH3
Available for: 2 Pole QP and QTs

Mechanical Interlock:

Mechanically interlocks two breakers so it is impossible for both to close at the same time ECQML12
Available for: QP and BL

Handle Blocking Device:

For holding device in “ON” and “OFF” position. Not a lockout/tagout device ECQL1, ECBX231M
Available for: QP, BL, QT

Sustainable solutions from Siemens. Ready today for the home of tomorrow.

VersiCharge™ Electric vehicle charging stations for home and fleet

  • Choice of four wiring methods to suit every install
  • Simple, intuitive user controls
  • Adjustable amperage output
  • 30 A and 70 A models to suit present and future vehicles
  • Unmatched feature set at competitive price point
  • Versi Charge SG is Smart Grid ready
    – Wireless communications
    – User and utility programmable
    – Optional revenue grade metering
    – Available in multiple colors to match decor

Customer Support

Legal Manufacturer
Siemens Industry, Inc.
3617 Parkway Ln
Peachtree Corners, GA 30092
United States of America
Telephone: +1 800-333-7421
www.usa.siemens.com/retail
Order No. RPPG-REFG1-0722
© 07.2022, Siemens Industry, Inc.
This document contains a general description of available technical options only, and its effectiveness will be subject to specific variables including field conditions and project parameters. Siemens does not make representations, warranties, or assurances as to the accuracy or completeness of the content contained herein. Siemens reserves the right to modify the technology and product specifications in its sole discretion without advance notice.