Important Safety Issues
- This product must be installed by a qualified electrician according to AS/NZS 3000.
- Ensure all electrical mains are disconnected before any installation.
- Modification of this product will void any warranty.
- Havit Lighting does not take responsibility for wrong installation, incorrect use, or use of installation material that does not belong to the system.
- When installing low voltage fittings, Voltage to fitting must be within +or- 5% of voltage required, if not within this allowance warranty will be voided.
- Aluminium and 304SS fittings must not be installed within 5km of any salt water environments.
- All o-rings and seals must be in place correctly to maintain warranty
- When installing surface mounted bollards, base plate must be installed on concrete or concrete pad, Fitting should not be installed under ground level, all holes including cable entry must be silliconed to prevent any water penetration into fitting, silicone must also be applied around fitting at ground level. Failure to do this will void warranty
- This form may be updated at any time due to product improvements, please check online installation form for most current version.
Product Specifications
Model No.| HV1628T-BLK-240V-RND| HV1629T-BLK-240V-RND|
HV1628T-BLK-24V-RND| HV1629T-BLK-24V-RND
---|---|---|---|---
Name| Divad
Material| Aluminium
Colour| Black
IP Rating| IP65
Input Voltage| 240v AC| 24V DC
Protection Class| (Requires Earth)| (Low Voltage)
Lamp Base| Built in LED
Lamp Wattage| 1x 12w
Colour Temp| TRI Colour – 3000k, 4000k, 5500k
Lumens| 960lm, 1020lm, 1080lm
CRI| > 80
Wiring| Parallel
Dimmable| No
Warranty| 3 Years Replacement*
Mounting Base
Dimensions
Steps for Installation: HV1628T-BLK-240V + HV1629T-BLK-240V
- Make sure that the electrical circuit is free of voltage (master switch off).
- Remove baseplate from fitting by removeing 4x allens screws on side of fitting and set aside.
- Install baseplate in desired location using appropriate screws for application. The screws supplied are mild steel which must be replaced with higher grade if there is any chance of them being affected by water. The location of baseplate must be installed on either concrete or concrete base and cannot be installed under ground level.
- Seal all holes in the base plate including cable entry and screw holes.
- Locate IP rated junction box within fitting. Undo screws from junction box and remove cover.
- Insert cable through cable gland on junction box. If your cable is not circular you must fix entry of your cable to maintain IP rating. Failure to do so will void warranty.
- Connect the cable using wire with earth. Connect earth first, then live and neutral wires.
- Reattach cover to IP rated junction box making sure screws are tight and seals are still in place.
- Affix the bollard to the baseplate by reattaching the 4 allen screws removed earlier making sure these are tight to reduce any movement in bollard.
- Colour temperature is set to 3000K. To change, remove top from fitting by loosening allen screws on side of fitting. Select desired colour temperature by moving switch located on bottom of top.
- Attach cover by tightening allen screws making sure the seals are still in place to avoid any water penetration.
- All connections must be carried out carefully, inspect all contacts before switching back on the electric circuit.
Steps for Installation: HV1628T-BLK-24V + HV1629T-BLK-24V
- Make sure that the electrical circuit is free of voltage (master switch off).
- Remove baseplate from fitting by removeing 4x allens screws on side of fitting and set aside.
- Install baseplate in desired location using appropriate screws for application. The screws supplied are mild steel which must be replaced with higher grade if there is any chance of them being affected by water. The location of baseplate must be installed on either concrete or concrete base and cannot be installed under ground level.
- Seal all holes in the base plate including cable entry and screw holes.
- Locate IP rated junction box within fitting. Undo screws from junction box and remove cover.
- Insert cable through cable gland on junction box. If your cable is not circular you must fix entry of your cable to maintain IP rating. Failure to do so will void warranty.
- Use an appropriate 24v DC LED Driver – DO NOT CONNECT LIGHT FITTING DIRECT TO 240V
- Connect the cable, Connect live then neutral wires.
- Reattach cover to IP rated junction box making sure screws are tight and seals are still in place.
- Affix the bollard to the baseplate by reattaching the 4 allen screws removed earlier making sure these are tight to reduce any movement in bollard.
- Colour temperature is set to 3000K. To change, remove top from fitting by loosening allen screws on side of fitting. Select desired colour temperature by moving switch located on bottom of top.
- Attach cover by tightening allen screws making sure the seals are still in place to avoid any water penetration.
- All connections must be carried out carefully, inspect all contacts before switching back on the electric circuit.
Must be installed by a licensed electrician