eLeKTRoTeCHNiK SCHABUS GX-K1 HFC Alarm Instruction Manual
- June 3, 2024
- Elektrotechnik SCHABUS
Table of Contents
SCHABUS GX-K1 HFC Alarm
Instruction Manual
Operating instructions
https://www.elektrotechnik-schabus.de/en/warnsysteme-gas- rauch/gasmelder/gx-k1-gasalarm
HFC ALARM GX-K1 / GX-K2 – Item no. 300931 / 300932.
Fluorinated hydrocarbons – coolants and refrigerants. Translated from the
German original: www.elektrotechnik-schabus.de
THANK YOU FOR YOUR CONFIDENCE!
In order to be able to constantly guarantee the product’s optimum
functionality and readiness for operation as well as your safety, we have a
request: Please thoroughly read this operating instruction prior to the first
use and observe all safety instructions! The operating instruction is a
component of this product. Keep this, so you can always refer to it.
DELIVERY SCOPE
► 1 HFC warning device: GAS ALARM GX-K1 or GX-K2
► mounting material (only GX-K2)
► 1 operating manual
SAFETY INSTRUCTIONS
General
- Before you start mounting the device please read the operating instructions carefully.
- The installation shall be performed by qualified personnel.
- Packaging material is not a chalder’s toy. Keep it away from children!
- Do not open the device. It does not contain parts you have to maintain.
Ambient conditions
The standards used to assess the product specify limit values for use in the
living area, business area and in small enterprises; the product has been
intended for use in the following operating environments:
- Residential buildings/living areas such as houses, flats, rooms, etc. selling areas such as shops, wholesale markets, etc.
- Premises of small enterprises such as workshops, service centers, etc.
- All areas of application characterize themselves by a connection to the public low voltage mains.
APPROPRIATE USE
The HFC ALARM GX-K1 with internal sensor or GX-K2 with external sensor is a
warning device for cooling and refrigerants of the HFCs group and already
warns at concentrations that are far below a life-threatening value.
This monitoring system is therefore set very sensitively according to its
purpose. The warning signal is acoustic and visual. The device is suitable for
normal household use and must not be used in areas where there is a risk of
explosion. The warning device warns of the toxic fumes that could escape from
leaking cooling and refrigeration systems and is primarily used to protect
people who should not inhale these fumes.
TECHNICAL SPECIFICATIONS
Operating voltage: | 230 (+/-10%) V AC / 50-60 Hz |
---|---|
Power consumption: | approx. 3 VA |
Protection type: | IP 20 |
Acoustic pressure sounder: | > 80 dB(A)@1m |
LED displays: | flashing green: preheating phase approx. 3 min. Glowing green: |
operation / monitoring Flashing yellow: malfunction, cable break, etc.
Flashing red: pre-alarm / main alarm
Type Sensor:| catalytic
Operating temperature:| -10 °C / +50 °C
Storage temperaturer:| -20 °C / +70 °C
Humidity (ambient):| 5–90 % RH (non-condensing)
Test interval:| about 5 years
Dimensions (HxWxD):| 118x60x44 mm
Cable length:| 2.5 m, not extendable only GX-K2
Cable Ø:| 3.5 mm only GX-K2
Dimensions sensor (HxWxD):| 52x27x29 mm ,only GX-K2
Sensitivity to:| R-22, -32, -404a, -410a, -1234yf and other HFCs
Cross-sensitivities to:| methane, butane, propane, ethanol, hydrogen and
other hydrocarbons
No sensitivity to:| carbon monoxide CO
Pre-alarm:| 100 – 10,000 ppm dep. on the type of refrigerant 3% LEL for
combustible gases
Main alarm:| e.g. R-32 from 1000 ppm @ 20°C environment
10 – 20% LEL, typically 12% LEL
INSTALLATION INSTRUCTIONS
The GAS ALARM GX-K1 / GX-K2 may only be installed in dry interior rooms and,
depending on the type of refrigerant, must be placed correctly to ensure that
the warning device functions correctly.
It is essential to observe the prescribed position of the alarm unit! For your
own safety and reassurance, please obtain information from your supplier
regarding their gas type and its properties!
Placement of the warning device/sensor for refrigerants whose vapors are
lighter than air: Plug the alarm into an overhead outlet or mount the sensor
at a height of 15-30 cm from the ceiling, but no more than 4 m from the air
conditioner.
Note: The alarm device/sensor must be installed above the highest door or
window opening in the room. For example, methane is lighter than air and
therefore rises.
Placement of the warning device/sensor for refrigerants whose vapors are
heavier than air: Plug the alarm into a socket below or mount the sensor at
a height of 15-30 cm from the floor, but no more than 4 m from the air
conditioner. For example, R-290/ propane is heavier than air and will sink to
the bottom. It spreads there like water and collects in depressions.
The alarm unit may not be used in the following positions:
- Places that could prevent the alarm from being triggered in the event of a gas leak (e.g. behind curtains or in cupboards, unless the air conditioning unit is in the same cupboard)
- directly above hearths or points of combustion or over a wash basin or sink
- next to a door, windows, ventilator, fan, air conditioning unit etc.
- in areas where dust or dirt can prevent the sensor from working
- in areas at risk of explosion.
INSTALLATION
The GAS ALARM GX-K1 / -K2 is simply plugged into a 230V / 50Hz socket. The LED
(Function) indicator lights up once in each color, a short alarm tone can be
heard. The sensor of the monitoring system needs a warm-up time of 3-5 minutes
to achieve functionality, during that time the green LED flashes. The LED
(Operate) then lights up green and the gas warning device is ready for
operation.
ATTENTION: Due to different transport conditions (long storage/humidity)
an alarm can be triggered immediately after the heating-up time (LED flashes
red). Briefly disconnect the device from the mains and start the heating time
again. This process may have to be repeated up to three times.
TEST button
In the event of an alarm, the alarm tone is muted with the TEST button, the
red LED continues to flash until no more gas is detected. In monitoring mode,
use the TEST button to test the function of the LEDs and the acoustic alarm
device. The sensor cannot be tested with it.
FAILURE
If a fault is detected, the LED (error) flashes yellow and the acoustic alarm
sounds every 30 seconds. Unplug the device and plug it in again, with the
GX-K2 please check the sensor cable and the plug on the sensor. Get in contact
with Elektrotechnik Schabus.
ALARM
Only when a gas or vapor concentration corresponding to the sensitivity is
detected does the pre-alarm start with a flashing red LED (alarm).
If the concentration continues to rise, the main alarm starts with the
acoustic alarm. The acoustics can be acknowledged with the TEST button.
WHAT TO DO IN CASE OF ALARM (or if you smell gas)
- Do not unplug the alarm unit!
- Do not switch on any other electrical devices or appliances
- Do not ignite any open flame, turn off any open flame already lit
- Immediately open windows and doors and thoroughly ventilate the area or house
- Turn off the main gas feed and ensure that the cause of the gas escape is eliminated
- In the event of persistent/repeated alarm, contact your energy supply expert/adviser or the fire service.
FALSE ALARM
The system‘s sensitive sensor also responds to many other gaseous media. The
use of aerosols (propellant in sprays for hair, disinfection, etc.), but also
strong tobacco smoke (e.g. smoking cards), cooking fumes and stored paint cans
can lead to false alarms. You can always recognize natural gas and bottled gas
by their distinct smell.
FUNCTIONAL TEST
A simple function test of the warning device is possible with the gas from a
standard lighter. A burst of gas (approx. 30 s) to the lower ventilation slots
of the housing or sensor without igniting the lighter triggers an alarm and
the LED (alarm) flashes red. Briefly disconnect the device from the mains and
restart the heating-up time.
For your own safety and reassurance, we recommend that you carry out this test
every month! Regularly clean the sensor by blowing off any dust.
The date (month/year) is at the sensor for the next sensor examination. Please
send the GA ALARM to us for the work examination.
Elektrotechnik Schabus GmbH & Co. KG
Baierbacher Str. 150
D-83071 Stephanskirchen
Germany
GENERAL
Elektrotechnik Schabus GmbH & Co. KG is not liable for damages and/or losses
of any kind such as individual damages or consequential damages brought about
by the gas detector not issuing an alarm despite the presence of an elevated
gas concentration.
CLEANING AND CARE
Avoid the effects of moisture (spray or rain water), dust as well as direct
insolation on the device. Clean the device exclusively with a dry linen cloth;
in case of heavy dirt accumulation, it may be slightly moistened. Do not use
any detergents containing solvents.
DECLARATION OF CONFORMITY
You can find the declaration of conformity at www.elektrotechnik-
schabus.de or request it from info
@elektrotechnik-schabus.de.
WARRANTY
We grant an implied warranty on material and quality defects of your
electronic product by Elektrotechnik Schabus from the date of purchase.
Elektrotechnik Schabus will repair or replace your device free of charge on
the following conditions:
- In case of implied warranty, the device has to be returned with the following documents: error description, proof of purchase as well as your address and delivery address (name, phone number, street, house number, postcode, city, country).
- Devices returned to Elektrotechnik Schabus shall be sufficiently packaged. Elektrotechnik Schabus will not take liability for any damage or loss during shipment.
- The device has to have been used in accordance with the operating instructions. Elektrotechnik Schabus will not take liability for any damage resulting from accident, abuse, modifications or carelessness.
- Elektrotechnik Schabus will not take liability for any loss, damage or costs resulting from the use of the devices or the accessory equipment.
- The warranty does not affect your statutory rights as consumer.
RETURN SHIPMENT
Should your device be defective, we offer you the following option:
Contact Elektrotechnik Schabus by
Phone: +49 (0) 80 36 / 67 49 79 – 0
Fax: +49 (0) 80 36 / 67 49 79 – 79
Email: info@elektrotechnik-schabus.de
ENVIRONMENTAL INFORMATION
For the production of the purchased product, natural raw materials had to be
obtained and used. It may contain substances hazardous to health and the
environment.
In order to avoid the distribution of these substances in your environment and
save natural resources, we ask you to use the appropriate take-back systems.
Thanks to these systems, the materials of your product can be recycled in an
environmentally friendly way, after its service life has expired. (WEEE-NO:
91394868)
The strike through wastepaper basket symbol. reminds you of the use of these
systems. Should you wish to obtain more information on collection, reuse and
recycling systems, please refer to the waste advisory service in your city.
You may also refer to us to obtain more information on the environmental
compatibility of our products.
Elektrotechnik Schabus GmbH & Co. KG
Baierbacher Str. 150
D-83071 Stephanskirchen
TEL: +49 (0) 80 36 / 67 49 79 – 0
FAX: +49 (0) 80 36 / 67 49 79 – 79
MAIL info@elektrotechnik-schabus.de
WEB www.elektrotechnik-schabus.de
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>