Hunter 19781 3 Light Chandelier Instruction Manual
- June 3, 2024
- Hunter
Table of Contents
Gatz
For Models: 19781/19782
3 Light Chandelier
Instruction Manual
19781 3 Light Chandelier
Fixture weight ±2 lbs.:
Peso ±2 lb.:
Pods fixe ±2 lbs.:| 6.8 lbs. (3.08 kg)
---|---
Hardware Service Kit
Part # | Model | Finish |
---|---|---|
KE99701L24 | 19781 | Palm Gold |
KE99701214 | 19782 | Brushed Nickel |
Glass
Part # | Model | Type |
---|---|---|
KE30401147 | 19781 | |
19782 | Clear Fluted Glass |
Here are the tools you’ll need to complete your installation:
Ladder | Screwdriver |
---|---|
Pliers | Wire Strippers |
**INSTALLATION INSTRUCTIONS
**
WARNING
- To avoid possible electrical shock, before installing your light fixture, disconnect the power by turning off the circuit breakers to the outlet box associated with the wall switch location.
- The lighting fixture must be grounded. If the ground wire for the installation site is not present, immediately STOP installation and consult a qualified electrician.
- All wiring must be in accordance with national and local electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring or in doubt, consult a qualified electrician.
READ AND SAVE THESE INSTRUCTIONS
These instructions are provided for your safety. It is very important that
they are read carefully and completely before beginning installation of the
lighting fixture.
PREPARING FOR INSTALLATION
Carefully remove all contents from the carton. Shut off the power at the circuit breaker and completely remove the old fixture from the ceiling, including the old mounting bracket. Remove the new mounting bracket assembly from the bag. One end of the threaded post (H) should be attached to the mounting bracket (A) with a hex nut (G) in place. The other end should be connected to the canopy loop (E). Unscrew the canopy loop ring (F) from the canopy loop (E). Depending on the placement of your junction box the position of threaded post (H) may need to be adjusted to allow the canopy to be flush with the ceiling. Determine this by lifting mounting bracket (A) up to the junction box and place canopy (D) over the canopy loop (E) so that it is flush with the ceiling. Adjust the position of threaded post (H) on the mounting bracket (A) so that the canopy (D) covers at least half of the exterior threads on the canopy loop (E) while it is securely connected to threaded post (H). The threaded post (H) can be adjusted by loosening hex nut (G) to allow movement of threaded post (H) on mounting bracket (A). Once the ideal position of the threaded post (H) is determined, tighten up the hex nut (G) onto the threaded post (H) just beneath the mounting bracket (A) to secure the threaded post in place.
ASSEMBLING THE FIXTURE
Slide spike (L) over the threaded post (M) on the fixture. Thread the wires
through center rod (K) and attach to the threaded post (M). There are 4
12-inch rods (I), and 1 6-inch rod (J) included for each fixture. Determine
the correct number of rods needed for proper hanging height. To lengthen the
fixture, add additional rods. To shorten the fixture, trim the wires to
desired length. Leave at least 8 to 10 inches of wire in addition to the
desired length and slide any excess rods off the fixture’s wiring to discard.
Keep in mind that you must use at least one rod to hang the fixture. Thread
the wires through the rods and pull the wires until taut before connecting the
rods together. All threads should be engaged but do not over tighten (some
manual straightening of the down rods may be required). Screw rod onto
threaded post of center rod (K). Pull the fixture wires through the canopy
loop ring (F), the canopy (D) and the canopy loop (E). Screw the top rod to
the canopy loop (E). Have a helper support the fixture’s weight and attach the
mounting bracket (A) to the junction box by securely tightening the mounting
screws (B). CONNECTING THE WIRES
Attach the fixture’s wires to the power supply wires from the junction box.
Connect black to black (live); white to white (neutral); grounding to
grounding (green or copper). Twist the ends of the wire pairs together. Then,
twist on a wire connector. Make sure all twists are in the same direction.
Loop fixture’s ground wire around grounding screw (C) and tighten. If there is
no ground wire (green or copper) from the junction box, contact a qualified
electrician.
FINISHING THE INSTALLATION
Place the canopy (D) flush to the ceiling and slide the canopy loop ring (F)
up beneath the canopy. Tightly screw canopy loop ring (F) onto the canopy loop
(E) to properly secure the canopy (D) in place. Screw the spike cluster (N) to
the threaded post (Q) at the bottom of the fixture. Install the glass shade
(O) by lining it up with the socket (P) and turning it to lock in place.
Install light bulb (not included) in accordance with the fixture’s
specifications. Do not exceed the recommended wattage. Turn on the power and
test the fixture. Your installation is now complete.
CLEANING TIPS
Treat the fixture gently! Regular cleaning will reduce the need for deep
cleaning. For regular cleaning, turn off the light and wipe down the fixture
with a clean lint-free cotton or microfiber cloth. Never spray cleaner
directly onto the fixture.
NOTICE
In order to use a 12in. rod by itself you must first remove the threaded post
from the 6in. rod and install it on one of the ends of the 12in. rod. Hunter
Pro Tip:
Twist or tape wire ends together to make it easier to pass them through the
downfolds. Threaded post may also be removed for easier wire access.
©2022 Hunter Fan Co. ML386
r_060122
Documents / Resources
|
Hunter 19781 3 Light
Chandelier
[pdf] Instruction Manual
19781, 19782, 19781 3 Light Chandelier, 19781, 3 Light Chandelier, Chandelier
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>