Shenzhen Maolunbu Technology A11 Smart Lock Instruction Manual
- June 3, 2024
- Shenzhen Maolunbu Technology
Table of Contents
Smart lock Manual
Technical parameters
Administrators :9
Unlock methods : Fingerprint, IC card, Password, Key, Tuya smart
Quiescent current : <50-65uA
Lower voltage alarm : 4.5±0.2V
Power supply : 4.5V-6V(4 pcs batteries)
Fingerprint : ≤50
Card : ≤100
Password : ≤ 100
Password length : 6-8 bit
Phantom password : 16 bit
Working temperature : -10°C–60°C
Product details
Any password, fingerprint, and IC card can be opened before leaving the
factory (the length of the password is 6-8 digits), which is to facilitate
user experience.
The temporary administrator password when leaving the factory is: 123456
Add fingerprint: Press the fingerprint 5 times, and the angle of the
fingerprint is as different as possible each time, and enter the fingerprint
on one finger into the system as much as possible.
Fake password: For example: the correct password is 112233, we can enter 5566
112233 5566 when unlocking, (5566 is a false password at this time, in order
to prevent others from remembering your password.)
- is the reverse, # is the confirm. After the system setting is completed, you can press to return or wait for the system to exit automatically.
Accessories
Item | Picture | Accessories | Quantity | Item | Picture | Accessories | Quantity |
---|---|---|---|---|---|---|---|
1 | Mortise lock | 1PC | 5 | Key | 2PC | ||
2 | Buckle Plate | 1PC | 6 | Square pole | 1PC | ||
3 | Buckle box | 1PC | 7 | Screw | 2PC | ||
4 | IC card | 2PC | 8 | Connecting rod | 2PC |
Door thickness
Suitable to 35mm ~ 70 mm thickness door.
Determine the door direction
When a person stands outside the door and opens the door with his left hand,
that means choosing the left open.
People who open the door with their right hand choose right open.
Change lock body direction
When installing the lock body ,the latch bolt is on the upper side,the dead bolt under the latch bolt,and the inclined surface of the latch bolt is facing the opening direction.
- Reserve the lock body and latch bolt is down(refer to picture 2)
- Push the latch bolt lower than front plate,stopblock is down and rotate 180 degrees (refer to picture 2)
- Push the latch bolt into hole (refer to picture 3)
Cutting template
- please refer template carefully to drill hole
- If there is a deviation in the hole,the mortise and panel assembly are put into. the door and the hole is corrected until appropriate.
SET UP
Connect with Tuya Smart APP
-
Set an administrator information (password or fingerprint or IC card) to the smart lock.
-
Set the lock time. Setting method: Refer to the above.
-
Download Tuya Smart or smart life on the mobile app store.
-
Open the Tuya Smart APP, register an account and log in 》Press on the smart lock 》
Enter administrator information # 》 Press 1 》Press 3 》 Press 2 (The lock 5 flashes)
Go to the APP interface and click Add Device 》Security Sensing 》Door Lock (wifi) 》Network Name,
Network Password 》Click (Confirm that the lock is flashing) 》Voice (connection is successful)
APP interface display: alarm, member management, door opening log, temporary password. -
Enter member management, the system displays (unassociated), click Unassociated “Edit” to add fingerprint (input the fingerprint number assigned by the door lock) or add a password (input the password number assigned by the door lock) or add an IC card (input the door lock allocation IC card number).
Other instructions
- If the smart lock cannot connect to wifi, please check whether the anti-lock switch is turned on.
- If the smart lock cannot connect to wifi, please check whether the battery is too low.
- If the error message is entered 5 times in a row, the system will automatically lock for 90 seconds.
- After the voltage is lower than 4.5V, it will automatically alarm every time the lock is unlocked, and the door lock can be opened 200 times after the alarm. Please replace the battery.
- In the setting, if there is no operation within 10 seconds, the system will automatically exit the setting.
- Normally open mode: press 5# after unlocking. (Anyone can open it without inputting information, input information: fingerprint ,password or IC card ). Convenient to use when working. When you enter the information again to unlock, the system will automatically change back.
- Insurance function: Press the Anti-lock switch, the user cannot unlock, only the administrator can unlock.
FCC Caution.
§ 15.19 Labelling requirements.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
§ 15.21 Information to user.
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
§ 15.105 Information to the user.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
RF warning for Mobile device:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated
withminimum distan ce 20cm between the radiator & your body.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>