Overview:

The unit converts a 12VDC-24VDC input into a regulated 24VDC ouput.

Altronix Model Number Output Input Cable Assembly Terminal Block
VB1 24VDC @ 0.75A 12VDC – 24VDC
VB1T 24VDC @ 0.75A 12VDC – 24VDC

Specifications:

Input:

  • 12VDC-24VDC input.

Output:

  • 24VDC @ 0.75A.
  • Electronically filtered and regulated output.
  • Built-in overload protection.

LED Indicators:

  • Power LED.

Applications:

  • Compensates for voltage drop due to long wire runs.

Applications (cont’d):

  • Power for 24VDC Access Control devices from a 12VDC power source.

Mechanical:

  • High-impact insulated housing.
  • Compact design allows for integration in a wide range of camera housings.

Dimensions (L x W x H approx.):
1.625” x 2.375” x 1” (41.3mm x 60.3mm x 25.4mm).

Altronix VB Series Power Voltage Boosters - fig1

Installation Instructions:

  1. Mount the unit in the desired location.

  2. a. VB1: Connect Yellow (positive) lead and Purple (negative) lead to 12VDC to 24VDC source. Observe polarity.
    b. VB1T: Connect 12VDC to 24VDC source to the terminals marked [Input +] and [Input –].

  3. Measure output voltage and check polarity before connecting devices in order to avoid potential damage.

  4. a. VB1: Connect Red lead [Pos. +] and Black lead [Neg. –] to 24VDC device to be powered.
    b. VB1T: Connect 24VDC device to be powered to terminals marked [+ DC –].

  5. LED will illuminate when power is present.

Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
web site: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty