hama 00186419 TS38G Outdoor Sensor Instruction Manual

June 4, 2024
Hama

Outdoor Sensor
Außensensor
TS38G

Operating Instructions

hama 00186419 TS38G Outdoor Sensor - fig1

Controls and displays
Measuring station

  1. Transmission indicator light
  2. Recess for wall mounting
  3. Channel switch(CH1,CH2, CH3)
  4. Battery compartment

Explanation of Warning Symbols and Notes

Warning
This symbol is used to indicate safety instructions or to draw your attention to specific hazards and risks.

Note
This symbol is used to indicate additional information or important notes.

PackageContents

  • TS38G OutdoorSensor
  • These operating instructions

SafetyNotes

  • The product is intended for private, non-commercial use only.
  • Do not operate the product outside the power limits given in the specifications.
  • Do not use the product in moist environments and avoidsplashes.
  • Do not use the product in the immediate vicinity of heaters or other heat sources or in direct sunlight.
  • Do not use production areas where the use of electronic devices is not permitted.
  • Do not put the product near interference fields, metal frames, computers, TVs, etc. Electronic devices and window frames can negatively affect the functionality of the product.
  • Do not drop the product and do not expose it to any major shocks.
  • Do not open the device or continue to operate it if it becomes damaged.
  • Do not attempt to service or repair the product yourself. Leave any and all service work to qualified experts.
  • Keep the packaging material out of the reach of children due to the risk of suffocation.
  • Dispose of packaging material immediately according to locally applicable regulations.
  • Do not modify the product in any way. Doing so voids the warranty.
  • Use the product for its intended purpose only.
  • Protect the product from dirt, moisture, and overheating, and only use it in an adry environment
  • Keep this product, as all electrical products, out of the reach of children!
  • Use the item only in moderate climatic conditions.

Warning –Batteries

  • When inserting batteries, note the correct polarity (+ and -markings) and insert the batteries accordingly. Failure to do so could result in the batteries leaking or exploding.
  • Only use batteries (or rechargeable batteries) that match the specified type.
  • Before you insert the batteries, clean the battery contacts and the polar contacts.
  • Do not allow children to change batteries without supervision.
  • Do not mix old and new batteries or batteries of different types or make.
  • Remove the batteries from products that are not being used for an extended period (unless these are being kept ready for an emergency).
  • Do not short-circuit batteries.
  • Do not charge batteries.
  • Do not throw batteries in a fire.
  • Keep batteries out of the reach of children.
  • Never open, damage or swallow batteries or allow them to enter the environment. They can contain toxic, environmentally harmful heavy metals.
  • Immediately remove and dispose of dead batteries from the product.
  • Avoid storing, charging or using the device in extreme temperatures and extremely low atmospheric pressure(for example, at high altitudes).

Getting started

  • Open the battery compartment (4)and in-seat two AA batteries with the correct polarity.
  • The battery compartment additionally contains the channel switch (3), which allows you to switch between the channelsCH1, CH2 andCH3. Set the channel switch to the desired channel.
  • Then close the battery compartment cover.

Replacing the batteries

  • Open the battery compartment (4), remove and properly dispose of the dead batteries and insert two new batteries with the correct polarity. Then close the battery compartment cover.

Note
Before use, make sure that you insert the batteries into the measuring station first and then in the base station.

Installation

Note –Installation

  • We recommend initially placing the base and measuring stations in the intended locations without installing them and making all the settings described in 6. Operation.
  • Only install the stations once the appropriate settings have been made and an astable wireless connection is established.

Note

  • The wireless transmission range between the measuring and base stationsisupto100 meters in open spaces.Before installation, ensure that wireless transmission will not be disrupted by interference or obstacles like buildings, trees, vehicles, high-voltage lines, etc.
  • Before final installation, ensure that there is sufficient reception between the intended installation locations.
  • When installing the measuring station, ensure that it is protected from direct sunlight and rain.
  • The international standard height for measuring air temperature, according to the German meteorological service,is2m(6.5 ft)above ground.

Warning –Batteries

  • Buyspecialorsuitable installation material from a specialized dealer for wall-mounting.
  • Ensure that no faulty or damaged parts are installed.
  • Never apply force during installation. This could damage the product.
  • Before installation, ensure that the chosen wall is suitable for the weight to be installed, and make sure that there are no electrical wires, water, gas or other lines in the wall at the installation site.
  • Do not mount the product above locations where epersonsmight linger.
  • We recommend installing the measuring station securely on an outdoor wall.
  • Installananchor, screw, nail, etc. in the wall of your choice.
  • Hang the measuring station using the open intended for this purpose (2).

Operation

6.1.Connectiontothe measuring station

  • To connect the base station and the measuring station, place the two devices as close together as possible.
  • After you insert the batteries, the base station automatically searches for a connection to the measuring station and performs the initial setup.
  • If the device does not connect automatically, the manual search program on the base station must be best rated.

Note

  • The initial setup takes approximately 2 minutes.
  • During the connection attempt, the radio symbol on the base station will flash.
  • Do not press any buttons during setup. Otherwise, values may not be transmitted correctly and there is a risk of value errors and inaccuracies.
  • The setup process is completed when the indoor and outdoor measurement data is displayed on the base station.
  • The measured value is automatically updated by the base device about every 45 seconds.
  • If the temperature is outside of the measuring range, –.- (lower than minimum temperature) or –.- (higher than maximum temperature) will appear on the temperature display.

6.2. Selecting the channel/Other measuring stations
**Note**

  • Ensure that the base station and measuring station are set to the same channel. Suitable base stations can be found at www.hama.com
  • The transmission channel on the supplied measuring station can be changed/set (CH1, CH2, CH3).
  • The measuring station is suitable for the following base stations: 186314, 186420

6.3. Low battery charge
Measuring station
If the batteries need to be replaced, the symbol for low battery charge will appear next to the outdoor temperature display on the base device. Replace the batteries immediately.

Note –Replacing the batteries

  • Note that the stations have to be resynchronized each time after you change the batteries in the measuring or base station.
  • To do this, remove the batteries from the other station and then reinsert them, or change them as required.

Care and Maintenance

  • Only clean this product with a slightly damp, lint-free cloth, and do not use aggressive cleaning agents.
  • Make sure that water does notget into the product.

Warranty Disclaimer

Hama GmbH &CoKGassumes no liability and provides no warranty for damage resulting from improper installation/mounting, improper use of the product or from failure to observe the operating instructions and/or safety notes.

Technical Data

Measuring station

Power supply| 1,5 V
2xAA batteries
---|---
Measuring range Thermometer Hygrometer| -40°C –+60°C/ -40°F –+140°F 1% –99%
Measurement increments Temperature Humidity| 0.1°C /0.2°F 1%
Measuring cycle thermometer/hygrometer| CH1 –ca. 114 s
CH2 –ca. 134 s
CH3 –ca. 158 s
DCF radio-controlled clock| No
Hygrometer| Yes
Thermometer| Yes
Max. number of measuring stations| 3
Range| Approx. 100 m

Recycling Information

Note on environmental protection:

After the implementation of the European Directive 2012/19/EU and 2006/66/EU in the national legal system, the following applies: Electric and electronic devices, as well as batteries, must not be disposed of with household waste. Consumers are obliged by law to return electrical and electronic devices as well as batteries at the end of their service lives to the public collecting points set up for this purpose or point of sale. Details to this are defined by the national law of the respective country. This symbol on the product, the instruction manual or the package indicates that a product is subject to these regulations. By recycling, reusing the materials or other forms of utilizing old devices/ batteries, you are making an important contribution to protecting our environment.

Declaration of Conformity

Hereby, Hama GmbH Et Co KG declares that the radio equipment type [00186419] is in compliance with Directive 2014/53/EU. — The full text of the EU declaration of conformity is available at the following internet address:
www.hama.com->00186419->Downloads.

Frequency band(s) 433.92 mW
Maximum radio-frequency power transmitted 0.14 mW

Hama GmbH &CoKG
86652 Monheim /Germany
Service &Support
www.hama.com
+49 9091 502-0
**D** **GB**

All listed brands are trademarks of the corresponding companies. Errors and omissions excepted, and subject to technical changes. Our general terms of delivery and payment are applied.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals