TDP 5500 E Deep Well Pump
TDP 5500 E / TDP 7500 E
EN
ORIGINAL INSTRUCTIONS DEEP WELL PUMP
TRT-BA-TDP5500E-TDP7500E-TC220308TTRT01-008-EN
Table of contents
Notes regarding the instructions …………………………………… 2 Safety
…………………………………………………………………………. 2 Information about the device………………………………………… 6
Transport and storage………………………………………………….. 6 Assembly and
installation…………………………………………….. 7 Operation ………………………………………………………………….. 10
Available accessories…………………………………………………. 10 Errors and
faults………………………………………………………… 11 Maintenance ……………………………………………………………… 12
Technical annex…………………………………………………………. 13 Disposal …………………………………………………………………….
16 Declaration of conformity …………………………………………… 16
Follow the manual Information marked with this symbol indicates that the
instructions must be observed. You can download the current version of the
instructions via the following link:
TDP 5500 E
https://hub.trotec.com/?id=42888
TDP 7500 E
https://hub.trotec.com/?id=42889
Notes regarding the instructions
Symbols
Warning of electrical voltage This symbol indicates dangers to the life and
health of persons due to electrical voltage.
Warning This signal word indicates a hazard with an average risk level which,
if not avoided, can result in serious injury or death.
Caution This signal word indicates a hazard with a low risk level which, if
not avoided, can result in minor or moderate injury.
Warning Warnings marked with this symbol indicate a risk of falling.
Note This signal word indicates important information (e.g. material damage),
but does not indicate hazards.
Info Information marked with this symbol helps you to carry out your tasks
quickly and safely.
Safety
Read this manual carefully before starting or using the device. Always store
the manual in the immediate vicinity of the device or its site of use.
Warning Read all safety warnings and all instructions. Failure to follow the
warnings and instructions may result in electric shock, fire and/or serious
injury. Save all warnings and instructions for future reference. This
appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given supervision or instruction concerning use of
the appliance in a safe way and understand the hazards involved. Children
shall not play with the appliance. Cleaning and user maintenance shall not be
made by children without supervision.
General safety
· Do not use the device in potentially explosive rooms or areas and do not
install it there.
· Do not use the device in aggressive atmosphere.
2
deep well pump TDP 5500 E / TDP 7500 E
EN
· Check accessories and connection parts for possible damage prior to every
use of the device. Do not use any defective devices or device parts.
· Before carrying out maintenance, care or repair work on the device, remove
the mains plug from the mains socket. Hold onto the mains plug while doing so.
· When positioning the device, observe the minimum distances from walls and
other objects as well as the storage and operating conditions specified in the
Technical annex.
· Do not remove any safety signs, stickers or labels from the device. Keep all
safety signs, stickers and labels in legible condition.
General safety warnings Electrical safety
· The device is to be supplied with a rated residual current of no more than
30 mA by means of an RCD (Residual Current protective Device).
· Ensure that all electric cables outside of the device are protected from
damage (e.g. caused by animals). Never use the device if electric cables or
the power connection are damaged!
· The mains connection must correspond to the specifications in the Technical
annex.
· Insert the mains plug into a properly fused mains socket.
· Switch the device off and disconnect the power cable from the mains socket
when the device is not in use.
· Do not under any circumstances use the device if you detect damages on the
mains plug or power cable. If the power cable is damaged, it must be replaced
by the manufacturer, its service agent or similarly qualified persons in order
to avoid a hazard. Defective power cables pose a serious health risk!
· Should there be a risk of flooding, install the plug connections in a flood-
proof area. There is a risk of electric shock!
· Make sure that the mains voltage corresponds to the specifications on the
nameplate.
· Have all electrical installations carried out by an expert according to the
national regulations and the devicespecific requirements.
· Do not use the power cable to drag the device.
· Hold onto the mains plug while pulling the power cable out of the mains
socket.
· Protect the power supply cable against heat, oil and sharp edges. Make sure
that the power supply cable is not crushed, kinked or subjected to other
mechanical stresses.
· Only use splash-proof extension cables intended for outdoor use whilst
observing the device’s power input. Before using cable drums, always unroll
the cable completely. Check the cable for damage. The use of extension cables
which are not approved for outdoor use can result in injuries due to electric
shock.
· Before performing any work on the device, in case of leaks in the water
system, before taking work breaks or when not in use, remove the mains plug
from the mains socket.
General safety warnings Personal safety
· Never use the device with persons or animals in the water or pumping medium
or if they could access it. There is a risk of electric shock!
· Never insert any objects or limbs into the device.
· This device is not a toy. Keep away from children and animals. Do not leave
the device unattended during operation.
Device-specific safety warnings for deep well pumps
· Only operate the device in an upright position.
· Keep in mind, that lubricants are used within the device. These might
potentially cause damages or contaminations if emitted. Do not use the device
for drinking water or in garden ponds with either a fish population or
valuable plants.
· Do not carry the device by holding it at the connection cable or hose. Do
not fasten it there either.
· Do not place any objects on the device not even to weight it down. The
device will sink to the ground due to its own weight.
· After the set-up of the device, its mains plug must be readily accessible
during operation.
· Prevent dry running of the device! Before start-up the device must be
completely submerged in the pumping medium.
· Do not under any circumstances connect a power cable directly to the device.
The device must not be used without the control box.
· Wear sturdy shoes to protect yourself against electric shock.
EN
deep well pump TDP 5500 E / TDP 7500 E
3
· Before taking the device into operation, have the following checked by an
expert:
earthing, neutral conductor and RCD must be functioning properly and
correspond to the national regulations,
electrical plug connections must be protected from moisture.
· Provide appropriate frost protection.
Intended use
The device TDP 5500 E / TDP 7500 E is exclusively designed for pumping clear
water from greater depths serving as service water for the home and garden.
The device can be applied for the following purposes: · water withdrawal from
wells and shafts
· rain water withdrawal from cisterns
In either case, the water must comply with the conditions specified in the
technical data.
The device is fully submersible (watertight encapsulation) and can be immersed
up to 20 m into the pumping medium.
Foreseeable misuse · The device is not suitable for continuous operation (e.g.
as
recirculation pump for ponds).
· Using the device in swimming pools and the like is prohibited.
· The device is not suitable as permanent, automatic overflow protection (of
e.g. wells or fountains or for the regulation of the groundwater level). Use a
stationary waste water pumping system for building and property drainage for
these purposes.
· The device is not suitable for increasing the pressure of existing water
supply networks.
· The device is not suitable for pumping potable water.
· The device must not be used for aggressive, abrasive, caustic, corrosive,
combustible or explosive pumping media, e.g.:
brine sandy water food cleaning agents fuels (e.g. petrol, diesel)
oils greases petroleum nitro-cellulose thinner waste water from
lavatories and urinal installations · The device must not be used at freezing
temperatures.
· Any unauthorised modifications, alterations or structural changes to the
device are forbidden.
Personnel qualifications People who use this device must: · be aware of the
dangers that occur when working with
electric devices in damp areas. · have read and understood the instructions,
especially the
Safety chapter. Installation and maintenance tasks which require the control
box to be opened must only be carried out by a qualified electrician.
Electrically skilled person Electrically skilled personnel must be able to
read and understand electric circuit diagrams, to put electrical systems into
service and to maintain them, to wire control cabinets, to ensure the
functionality of electrical components and to identify possible hazards from
electrical and electronic systems. Safety signs and labels on the device
Note Do not remove any safety signs, stickers or labels from the device. Keep
all safety signs, stickers and labels in legible condition.
The following safety signs and labels are attached to the device:
This label indicates the following safety warnings: · Prevent dry running of
the pump! Before start-up the pump
must be completely submerged in the pumping medium. · Carefully read the
instructions before starting or using the
pump. · Do not under any circumstances connect a power supply
cable directly to the pump! The pump may only be used in combination with the
supplied control box.
4
deep well pump TDP 5500 E / TDP 7500 E
EN
· Insert the mains plug of the control box into a properly fused mains socket.
This label indicates the following safety warnings: · The oil filling screw
must not be screwed off when the
motor is operating! · Please note that the warranty will be voided if the pump
is
operated without the supplied control box. · Turn off the power supply if
after start-up of the motor the
pump shows an unusual operational behaviour (such as strong vibrations at the
pump or pressure line, a fluctuating flow rate or similar).
This label indicates the following safety warning: · Disconnect the power
supply before opening the cover.
Residual risks
Warning of electrical voltage Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage Before any work on the device, remove the mains
plug from the mains socket! Do not touch the mains plug with wet or damp
hands. Hold onto the mains plug while pulling the power cable out of the mains
socket.
Warning Dangers can occur at the device when it is used by untrained people in
an unprofessional or improper way! Observe the personnel qualifications!
Warning The device is not a toy and does not belong in the hands of children.
Warning Risk of suffocation! Do not leave the packaging lying around. Children
may use it as a dangerous toy.
Note If you store or transport the device improperly, the device may be
damaged. Note the information regarding transport and storage of the device.
Behaviour in the event of an emergency 1. Switch the device off. 2. In an
emergency, disconnect the device from the mains
feed-in: Hold onto the mains plug while pulling the power cable out of the
mains socket. 3. Do not reconnect a defective device to the mains.
Overheating protection The device is provided with a thermal protection
circuit which is activated by overheating of the device and then switches the
device off.
Switch the device off and let it cool down. Investigate the cause of
overheating. Should the problem persist, please contact the customer service.
EN
deep well pump TDP 5500 E / TDP 7500 E
5
Information about the device
Device description The device TDP 5500 E / TDP 7500 E is particularly well
suited for pumping clear water from greater depths, e.g. from wells or shafts.
The device is able to pump up to 6000 l (TDP 5500 E) or 4800 l (TDP 7500 E)
per hour from a working depth of up to 20 metres. In doing so, the device
reaches a delivery head of up to 58 metres (TDP 5500 E) or 93 metres (TDP 7500
E). The device is equipped with an external control box allowing for safe
operation of the device outside the place of installation at all times. An
overload switch protects the device against damage caused by overload. The
water temperature must not exceed 35 °C.
Info The illustrations in these instructions feature the device TDP 5500 E by
way of example. The represented operating steps and explanations also apply to
device TDP 7500 E unless otherwise mentioned.
Device depiction
10 1
2
9
8
3
4
5
7
6
No. Designation 1 Connection for pressure line with 1 ¼” internal thread 2
Pump 3 Control box 4 On/off switch with protective cover 5 Overload switch
with protective cover 6 Power cable 7 Motor 8 Dirt strainer 9 Suspension eye
10 Control box connection cable
Transport and storage
Note If you store or transport the device improperly, the device may be
damaged. Note the information regarding transport and storage of the device.
Transport Before transporting the device, observe the following: · Hold onto
the mains plug while pulling the power cable out
of the mains socket. · Do not use the connection cable to drag the device. ·
Do not carry the device by holding it at the connection
cable or hose.
Storage When the device is not being used, observe the following storage
conditions: · Store the device in a dry location and protected from frost
and heat. · Store the appliance in an upright position where it is
protected from dust and direct sunlight. · If required, use a cover to protect
the device from invasive
dust. · Check whether there is residual water left in the device,
and drain any residual water to prevent rust formation. · Put the protective
cap on the pressure connection to
protect the inside of the device against dust and dirt.
6
deep well pump TDP 5500 E / TDP 7500 E
EN
If you do not use the device for an extended period of time, it must be
cleaned thoroughly after its last application and before recommissioning.
Deposits and residues could lead to start-up difficulties. For restart, please
proceed according to the Start-up chapter.
Assembly and installation
Scope of delivery · 1 x Deep well pump · 1 x Control box · 1 x Manual
Unpacking the device 1. Open the cardboard box and take the device out. 2.
Completely remove the packaging. 3. The device is additionally packed in a
cardboard tube (11).
One end of this tube is closed by a screwed-down cover (12). Loosen the screws
with a suitable screwdriver and remove the cover (12).
Start-up
Connecting the pipe or hose line
The device may be operated using either a hose line or a pipe. Ex factory, the
device is delivered with a 1 ¼” internal thread.
Please observe the following information regarding water discharge: · The
device cannot be moved flexibly when using a solid
pipe.
· Please note that the conveying capacity declines with an increasing height
of the pressure line.
Note If you want to connect a flexible hose as pressure line, do not use a
suction hose or a non-pressure-resistant hose. Use pressure-resistant hoses
only.
Connecting the pressure line
Warning Make sure that all parts of the pressure line are installed
professionally. In case of an improper assembly or when using unsuitable
parts, there is a risk of injury due to the pressurized pumping medium.
1. Remove the protective cap (13) from the pressure connection (1).
13
11
12
1
4. Carefully pull the device out of the cardboard tube (11). 5. Fully unwind
the power cable. Make sure that the power
cable is not damaged and that you do not damage it during unwinding.
Note
Keep the protective cap (13) of the pressure connection so you can use it when
storing the pump to protect the inside of the pump against dust and dirt.
EN
deep well pump TDP 5500 E / TDP 7500 E
7
2. Connect the pressure line to the pressure connection (1) using a suitable
adapter (1 ¼”). To do so, apply thread seal tape (e.g. Teflon tape) to the
threaded connector of the pressure line to ensure a leak-proof connection.
Installing the control box Warning of electrical voltage Work on the
electrical components must only be carried out by a qualified electrician!
Warning of electrical voltage Disconnect the power supply before opening the
cover! Warning of electrical voltage The device must not be operated without
the control box (3).
1. Make sure that there is a socket secured with a 30 mA residual current
device available near the place of installation.
2. Install the control box (3) at a suitable position according to the
protection class (protected from weather exposure and spray water, in a flood-
proof area). Please note that the control box must not be installed inside the
well shaft.
3. Have the connection cable (10) connected to the control box (3) by a
qualified electrician in accordance with the wiring diagram in the chapter
Technical annex.
Installing the device
Please observe the following information regarding the device set-up and
before switching the device on: · The shaft/the drill hole should be vertical
and the shaft
walls should not have any protruding edges or projections.
· The shaft/the drill hole should have an edge length/a diameter of at least
110 mm.
· Do not leave the device running unattended.
· Check whether the hose or pipe was attached properly.
· Make sure that the connection cable (10) is not under tensile load and has
enough clearance.
· Make sure that the mains connection corresponds to the specifications
provided in the technical data.
· Check the mains socket for its proper condition. The mains socket’s fusing
must be sufficient.
· Make it impossible for moisture to reach mains plug or socket. There is a
risk of electric shock!
Warning of electrical voltage There is a risk of electric shock when
submerging the device in the pumping medium. Before submerging the device in
the pumping medium, please note the following: · Make sure that the mains plug
is removed.
· Check the mains plug, the power cable (6) and the connection cable (10) for
damage. Do not under any circumstances use the device if you detect damages on
the mains plug, power cable (6) or connection cable (10).
Warning of electrical voltage Electric shock due to damaged connection cable
(10). Do not under any circumstances use the connection cable (10) for
lowering, securing, positioning or lifting the device. Only use a suitable
cord or rope, e.g. a nylon cord or a wire rope.
Warning There is a risk of falling into the shaft or drill hole. Position the
device in a way that the shaft or drill hole opening is closed before, during
and after operation to prevent persons or animals from falling in.
Note At the bottom of ponds and other waterbodies deposits may have
accumulated over time. To prevent the device from being damaged, it should not
be lowered all the way to the ground. Observe a minimum distance of 50 cm to
the ground.
8
deep well pump TDP 5500 E / TDP 7500 E
EN
1. Fasten a suitable cord or rope, e.g. a nylon cord or a wire rope, to the
suspension eye (9) on top of the device.
20 m
9
Installation with pressure switch TDP DS / TDP DSP (optional)
Warning of electrical voltage Work on the electrical components must only be
carried out by an authorised specialist company!
For switching a connected deep well pump on or off and for monitoring the
pressure in the pipe, the device can be installed together with pressure
switch TDP DS or TDP DSP.
See also chapter Available accessories.
Recommendation for usage: · in order to install and use the device in a
permanent /
stationary manner, use the pressure switch TDP DS
· in order to install and use the device in a temporary / location-independent
manner, use the pressure switch TDP DSP
2. Slowly lower the device and the cord/rope into the pumping medium. Pay
attention to the following: ð The device must be lowered into the pumping
medium perpendicularly. ð The device must be completely submerged in the
pumping medium. Regularly check the water level to prevent the device from
running dry. ð Observe a minimum distance of 50 cm to the ground (see also
schematic representation in the chapter Technical annex).
3. Attach the cord or rope to an easily accessible position, so you can pull
the device back out as required.
EN
deep well pump TDP 5500 E / TDP 7500 E
9
Operation
Switching the device on Once you have completely installed the device as
described in the chapter Assembly and start-up, you can switch it on.
Warning of electrical voltage Do not touch the mains plug with wet or damp
hands.
Note Please note that the device is designed for max. 20 switch-on/switch-off
operations per hour. Before every restart, wait for at least 3 minutes.
Switching the device off
1. Switch the device off by setting the on/off switch (4) to position 0.
1. Plug the mains plug into a sufficiently fused mains socket. 2. Switch the
device on by setting the on/off switch (4) to
position I.
4
3. After switch-on, regularly check whether the device operates correctly.
Turn off the power supply if after startup of the motor the pump shows an
unusual operational behaviour (such as strong vibrations at the pump or
pressure line, a fluctuating flow rate or similar). If you leave the device
unattended for a longer period of time, interrupt the device’s power supply.
Shutdown
Warning of electrical voltage Do not touch the mains plug with wet or damp
hands. 1. Switch the device off by setting the on/off switch (4) to position
0. 2. Hold onto the mains plug while pulling the power cable out of the mains
socket. 3. Pull the device out of the pumping medium by means of the cord or
rope. 4. Disconnect the pressure line. 5. Clean the device according to the
Maintenance chapter. 6. Store the device according to the Storage chapter.
Available accessories
Warning Only use accessories and additional equipment specified in the
instructions. Using insertion tools or accessories other than those specified
in the instructions may cause a risk of injury.
Accessories TDP DSP (with plug) TDP DS (without plug)
Article number 4.610.000.291 4.610.000.290
10
deep well pump TDP 5500 E / TDP 7500 E
EN
Errors and faults
Warning of electrical voltage Do not touch the mains plug with wet or damp
hands.
Warning of electrical voltage
Tasks which require the device to be opened must only be carried out by
authorised specialist companies or by Trotec. · Switch the device off.
· Hold onto the mains plug while pulling the power cable out of the mains
socket.
The device has been checked for proper functioning several times during
production. If malfunctions occur nonetheless, check the device according to
the following list.
The device does not start: · Check the power connection.
· Check the power cable and mains plug for damage.
· Check the on-site fusing.
· The device might have overheated and the thermal protection circuit is
activated.
If so, wait for approx. 10 minutes before restarting the device. If the device
is not starting, have the electrics checked by a specialist company or by
Trotec.
· The water temperature is above 35 °C and the thermal protection circuit is
activated.
The device is running, but not pumping any water: · Check whether the dirt
strainer (8) is clogged. Remove any
obstructions.
· Check whether the water level is too low or the device is not completely
submerged. If necessary, submerge the device deeper into the water.
· Check whether the used hose diameter is too small.
· Check whether the hose line is kinked or blocked. Remove kinks and / or
blockages.
The device switches off after a brief runtime: · Check the water for dirt. If
the water is too dirty, the device
will become hot and the thermal protection circuit will switch the device off.
· Check whether the water temperature is too high. The device might have
overheated due to a too high water temperature and the thermal protection
circuit is activated.
· Check the power connection.
· Check the power cable and mains plug for damage.
· Check the on-site fusing.
Insufficient or decreasing conveying capacity: · Check whether the dirt
strainer (8) is clogged. Remove any
obstructions.
· Check the hose diameter and the delivery head. An excessive delivery head
paired with a small hose diameter can cause a reduction of the conveying
capacity.
· Check whether the hose line is kinked or blocked. Remove kinks and / or
blockages.
Note Wait for at least 10 minutes after maintenance and repair work. Only then
switch the device back on.
The device still does not operate correctly after these checks:
Please contact the customer service. If necessary, bring the device to an
authorised specialist electrical company or to Trotec for repair.
EN
deep well pump TDP 5500 E / TDP 7500 E
11
Maintenance
Activities required before starting maintenance
Warning of electrical voltage Do not touch the mains plug with wet or damp
hands. · Switch the device off. · Hold onto the mains plug while pulling the
power cable out of the mains socket.
Notes on maintenance Inside the device, there are no parts that need to be
maintained or lubricated by the user.
Safety signs and labels on the device Check the safety signs and labels
attached to the device at regular intervals. Replace illegible safety signs!
Cleaning · Clean the device with a soft, damp and lint-free cloth.
Protect electrical components from moisture. Do not use any aggressive
cleaning agents such as cleaning sprays, solvents, alcohol-based or abrasive
cleaners to dampen the cloth. · Rinse the inside of the device with clear,
lukewarm water.
12
deep well pump TDP 5500 E / TDP 7500 E
EN
Technical annex
Parameter Model Max. flow rate Max. delivery head Max. submersion depth
Speed Max. pressure Min. ambient temperature Max. ambient temperature Mains
connection Number of phases Max. power input Max. pump capacity Protection
type of the pump Protection type of the control box Protection class
Connection type Cable length of the control box Cable length of the pump Min.
drill hole diameter Minimum distance to the ground Threaded connector, inner
diameter Pump dimensions (length x width x height) Pump weight Control box
dimensions (length x width x height) Control box weight Conditions for the
pumping medium (water) Max. water temperature Max. particle size Max. chloride
content Max. hydrogen sulphide content Min. pH Max. pH
Technical data
Value TDP 5500 E 100 l/min 58 m
TDP 7500 E 80 l/min 93 m
20 m 2850 rpm 5,8 bar 0 °C 35 °C 220 V – 240 V ~ 50 Hz 1 1100 W 550 W IP68 IP44 I CEE 7/7 1.2 m 23 m 110 mm 0.5 m 1 ¼”
20 m 2850 rpm 9,3 bar 0 °C 35 °C 220 V – 240 V ~ 50 Hz 1 1500 W 750 W IP68 IP44 I CEE 7/7 1.2 m 23 m 110 mm 0.5 m 1 ¼”
780 x 92 x 100 mm 13.5 kg
930 x 92 x 100 mm 15.5 kg
143 x 185 x 70 mm 0.74 kg
143 x 185 x 70 mm 0.74 kg
35 °C 2.3 mm 1.5 mg/l 400 mg/l 6.5 8.0
EN
deep well pump TDP 5500 E / TDP 7500 E
13
Schematic representation TDP 5500 E
max. 35°
TDP 7500 E
max. 35°
93 m max.
58 m max.
20 m max.
0,5 m min.
20 m max.
Performance chart (delivery head / flow rate) TDP 5500 E
m 60 50 40 30 20 10 0
Eta(%) 60 40 20 0
10 20 30 40 50 60 70 80 90 100
0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5,5 5 6
l/min m³/h
TDP 7500 E
m 90 75 60 45 30 15 0
Eta(%) 60 40 20 0
0
10 20 30 40 50 60 70 80 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5
l/min m³/h
0,5 m min.
14
deep well pump TDP 5500 E / TDP 7500 E
EN
Wiring diagram
TDP 5500 E / TDP 7500 E
EN
deep well pump TDP 5500 E / TDP 7500 E
15
Disposal
Always dispose of packing materials in an environmentally friendly manner and
in accordance with the applicable local disposal regulations.
The icon with the crossed-out waste bin on waste electrical or electronic
equipment stipulates that this equipment must not be disposed of with the
household waste at the end of its life. You will find collection points for
free return of waste electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local administration. You
can also find out about other return options that apply for many EU countries
on the website https:// hub.trotec.com/?id=45090. Otherwise, please contact an
official recycling centre for electronic and electrical equipment authorised
for your country.
The separate collection of waste electrical and electronic equipment aims to
enable the re-use, recycling and other forms of recovery of waste equipment as
well as to prevent negative effects for the environment and human health
caused by the disposal of hazardous substances potentially contained in the
equipment.
Only for United Kingdom
According to Waste Electrical and Electronic Equipment Regulations 2013 (SI
2013/3113) (as amended) devices that are no longer usable must be collected
separately and disposed of in an environmentally friendly manner.
Applied national standards and technical specifications: · EN
60335-1:2012/A1:2019 · EN 60335-1:2012/A2:2019 · EN 60335-1:2012/A14:2019 · EN
60335-2-41:2003/A2:2010 · EN 61000-3-3:2013/A2:2021 · EN 62233:2008 · EN IEC
55014-1:2021 · EN IEC 55014-2:2021 · EN IEC 61000-3-2:2019/A1:2021
Manufacturer and name of the authorised representative of the technical
documentation: Trotec GmbH Grebbener Straße 7, D-52525 Heinsberg Phone: +49
2452 962-400 E-mail: info@trotec.de
Place and date of issue: Heinsberg, 12.07.2022
Detlef von der Lieck, Managing Director
Declaration of conformity
Declaration of conformity in accordance with the EC Machinery Directive
2006/42/EC, Annex II, Part 1, Section A
We Trotec GmbH declare in sole responsibility that the product designated below was developed, constructed and produced in compliance with the requirements of the EC Machinery Directive in the version 2006/42/EC.
Product model / Product:
TDP 5500 E TDP 7500 E
Product type:
deep well pump
Year of manufacture as of: 2022
Relevant EU directives: · 2011/65/EU
· 2012/19/EU
· 2014/30/EU
Applied harmonised standards: · None
16
deep well pump TDP 5500 E / TDP 7500 E
EN
Trotec GmbH
Grebbener Str. 7 D-52525 Heinsberg
+49 2452 962-400 +49 2452 962-200
info@trotec.com www.trotec.com