Honeywell CO60PM Series Portable Evaporative Air Cooler User Manual
- June 3, 2024
- Honeywell
Table of Contents
CO60PM Series Portable Evaporative Air Cooler
User Manual
CO60PM Series Portable Evaporative Air Cooler
Read and save these instructions before use
Model: CL60PM/CO60PM Series
http://honeywellaircomfort.com/
PARTS DESCRIPTION
- Control Panel
- Water Level Indicator
- Water Inlet Hole
- Handle
- Left Side Grill
- Lever for Horizontal Louvers
- Water Tank
- Casters
- Louvers| 11) Power Cord & Plug
- Rear Grill
- Drain Plug
- Rear Grill Screws
- Right Side Grill
- Water Inlet Valve
- Honeycomb Cooling Media
(Media is on 3 sides)
---|---
WARNING — READ AND SAVE THE AIR COOLER SAFETY & MAINTENANCE GUIDE AND
USER MANUAL BEFORE USING THIS PRODUCT. FAILURE TO FOLLOW THESE INSTRUCTIONS
MAY DAMAGE AND/ OR IMPAIR ITS OPERATION AND VOID THE WARRANTY. IN CASE THERE
IS ANY INCONSISTENCY OR CONFLICT BETWEEN THE ENGLISH VERSION AND ANY OTHER
LANGUAGE VERSION OF THE CONTENT OF THIS MATERIAL, THE ENGLISH VERSION SHALL
PREVAIL.
WARNING: FOR OUTDOOR MODEL CO60PM (in USA), USE ONLY ON GFCI PROTECTED
RECEPTACLES.
USE & OPERATION
CONTROL PANEL
FUNCTION BUTTONS
SPEED/ON – OFF
Connect to the power supply and turn the SPEED knob. The fan will start.
Change the speed from 3 to 1 (1 for Low, 2 for Medium and 3 for High fan
speed). To switch OFF the unit, turn the SPEED knob to 0.
COOL
You must add water before operating the unit on Cool mode. Turn the COOL knob
to the ON position to activate evaporative cooling. The water pump will
operate and you will feel the cooler air after the Honeycomb Cooling Media is
completely wet.
SWING
Turn the SWING knob to the ON position to activate the movement of the
louvers. The louvers will begin to move left to right automatically. Vertical
Air Flow – You can manually adjust the lever located at the front of the unit
to change vertical air flow.
COOLER LOCATION
Make sure to position the air cooler correctly before you set up and start
using the product. Please refer to the COOLER LOCATION section of the separate
Safety & Maintenance Guide.
FILLING WITH WATER
It is ideal to use the Continuous Water Supply Connection to run the unit for
long periods of time without refilling the tank. This also helps prevent pump
failure in case the cooler is running with inadequate water in the tank.
CAUTION: Unplug the unit from the electrical power outlet before filling
or emptying the water tank.
Continuous Water Supply Connection:
For a continuous water supply, you will need a garden hose that is connected
to a main water supply.
Note: The garden hose is not included. Please make use of a garden hose
which is compatible with the unit connection.
- Locate the male connector at one end of the garden hose. Insert the garden hose connector into the water inlet valve of the cooler. Screw and tighten the water inlet valve onto the threaded part of the garden hose connector, making sure the hose connector is secured to ensure there will be no leaks. If there is leakage, the hose and the water inlet valve may not be connected properly. Try to disconnect, replace and tighten the water inlet valve again.
- When the connection is secured, turn ON the water supply and the water will flow into the water tank of the cooler.
- The cooler is now set so the water refills automatically.
- When the water tank is full, the water inlet valve will automatically stop the water supply from overflowing.
- Please open the water valve for minimum flow as too much pressure could damage the inlet pressure control system.
WARNING: The maximum water inlet pressure is 0.5 MPa.
Manual Water Tank Refill:
- Using a portable container or a garden hose, you can refill the water tank manually by pouring water into the water tank through the water inlet hole located at the top of the air cooler.
- Check the water level indicator to know when the water tank is full. Do not fill water above the “Max.” water level mark to avoid water droplets collecting on the louvers.
WARNING: Always ensure the water in the water tank is above the minimum
(Min.) water level mark for both Continuous & Manual Water Refill. Running the
unit in Cool mode with inadequate water may cause pump failure.
Note: The water capacity refers to the total volume of water that can be
contained within the air cooler water tank and water distribution system. The
water capacity in the tank at the “Max.” indicator level may be lower than the
actual water capacity of the air cooler.
WARNING: Do not fill water tank with dirty water or salt water. This can
damage the unit and Honeycomb media.
**LOW WATER PUMP CUT-OFF**
In Cooling Mode, when water in the tank is below the minimum indicator level,
the air cooler water pump will automatically turn off. This helps to protect
the water pump from running without water in the tank. When the water pump is
turned off, the air coolers stops evaporative cooling.
To reactivate the water pump and restart the unit in Cooling Mode, first
switch OFF the unit and unplug from the power outlet. Fill the water tank with
fresh water above the minimum level mark. Plug in and switch the unit ON
again.
Applicable for models with Low Water Pump Cut-off only.
CLEANING & DRAINING THE WATER TANK
If the cooler will not be used for a long period of time, please refer to the
STORAGE & MAINTENANCE GUIDELINES located in the separate Safety & Maintenance
Guide.
WARNING:
Before cleaning the unit, switch the unit OFF and disconnect from the
electrical socket.
- Move the unit to a location where the water can be drained. Remove the cap from the Drain plug located at the bottom of the unit. Allow the tank to empty.
- Refill the water tank with clean water, up to the maximum level and drain it completely.
- Use a damp cloth to remove the dirt and dust from the surface of the unit. Never use corrosive elements or chemicals to clean this product.
- When the product is not in use, store the unit in a dry place away from direct sunlight.
CLEANING THE HONEYCOMB COOLING MEDIA
- The appliance is supplied with three Honeycomb Cooling Media pads.
- The Honeycomb Cooling Media are located inside the Rear and Side Grills. Follow Steps 1 to 5 for instructions on how to remove them from the unit for cleaning and maintenance.
- Do not run the unit in COOL mode with stale water in the tank. You must empty the water tank and refill with fresh water, especially if the tank has not been cleaned in a long time.
- The cleaning frequency for the Honeycomb media depends on local air and water conditions. In areas where the mineral content of water is high, mineral deposits may build up on the Honeycomb Cooling Media and restrict air flow. Draining the water tank and refilling with fresh water at least once a week will help reduce mineral deposits. If mineral deposits remain on the Honeycomb Cooling Media, the media should be removed and washed under fresh water. The media should be cleaned every two months or sooner, depending on your needs.
- For best results allow the Honeycomb Cooling Media to dry after each use by turning off the cool function 15 minutes before turning the unit off.
Removing the Honeycomb Cooling Media:
- Remove the screws from the Rear Grill of the Air Cooler.
- Carefully pull out the Rear Grill from the Air Cooler.
- The Honeycomb Cooling Pad is secured on the Rear Grill by two Horizontal Bars that are fixed in place by two screws on the Left and Right Sides of these Horizontal Bars. Remove these screws to release the Horizontal Bars. Pull out the Honeycomb Cooling Pad by sliding it out from the Rear Grill. Replace with the new Honeycomb Cooling Pad by sliding into the grooves of the Rear Grill until it fits comfortably and securely in place on the grill. Replace the Horizontal Bars back onto the Rear Grill by replacing the Left and Right Side screws and tightening them in place. This secures the Honeycomb Cooling Pad in place on the Rear Grill.
- Repeat steps 1 to 4 to remove the Honeycomb Cooling Pad on the Left and Right Side Grills.
WARNING: DO NOT operate the Air Cooler when any or all of the Rear or Side Grills are removed from the Air Cooler, or if there is a loose-fitting Rear or Side Grill. Doing so can cause serious injury or dangerous electrical shock.
Made in China
© 2021 JMATEK Limited. All rights reserved.
The Honeywell Trademark is used under license from Honeywell International
Inc.
Honeywell International Inc. makes no representations or warranties with
respect to this product.
This product is manufactured by Airtek Int’l Corp. Ltd. (subsidiary of JMATEK
Ltd.).
JMATEK UK Limited
Keizersgracht 62
1015 CS Amsterdam
Netherlands
Tel: +31 20 5207422
Support.eu@jmatek.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>