HIRSCHMANN BRS20-8TX-EEC Managed Industrial Switch Owner’s Manual
- June 3, 2024
- HIRSCHMANN
Table of Contents
HIRSCHMANN BRS20-8TX-EEC Managed Industrial Switch
Configurator Description
The Hirschmann BOBCAT Switch is the first of its kind to enable real-time communication using TSN. To effectively support the increasing real-time communication requirements in industrial settings, a strong Ethernet network backbone is essential. This compact managed switches allow for expanded bandwidth capabilities by adjusting your SFPs from 1 to 2.5 Gigabit – requiring no change to the appliance.
Technical Specifications
Product description
Type | BRS20-8TX-EEC (Product code: BRS20-08009999-TTCY99HHSESXX.X.XX) |
---|---|
Description | Managed Industrial Switch for DIN Rail, fanless design Fast |
Ethernet Type
Part Number| 942170012
Port type and quantity| 8 Ports in total: 8x 10/100BASE TX / RJ45
More Interfaces
Power supply/signaling contact| ****
1 x plug-in terminal block, 6-pin
---|---
Digital Input| 1 x plug-in terminal block, 2-pin
Local Management and Device Replacement| ****
USB-C
Network size – length of cable
Twisted pair (TP) | 0 – 100 m |
---|
Network size – cascadibility
Line – / star topology | any |
---|
Power requirements
Operating Voltage | 2 x 12 VDC … 24 VDC |
---|---|
Power consumption | 6 W |
Power output in BTU (IT)/h | 20 |
Software
Switching
| Independent VLAN Learning, Fast Aging, Static Unicast/Multicast Address
Entries, QoS / Port Prioritization (802.1D/p), TOS/DSCP Prioritization,
Interface Trust Mode, CoS Queue Management, Queue-Shaping / Max. Queue
Bandwidth, Flow Control (802.3X), Egress Interface Shaping, Ingress Storm
Protection, Jumbo Frames, VLAN (802.1Q), GARP VLAN Registration Protocol
(GVRP), Voice VLAN, GARP Multicast Registration Protocol (GMRP), IGMP
Snooping/Querier per VLAN (v1/v2/v3), Unknown Multicast Filtering, Multiple
VLAN Registration Protocol (MVRP), Multiple MAC Registration Protocol (MMRP),
Multiple Registration Protocol (MRP)
---|---
Redundancy| HIPER-Ring (Ring Switch), Link Aggregation with LACP, Link Backup,
Media Redundancy Protocol (MRP) (IEC62439-2), Redundant Network Coupling, RSTP
802.1D-2004 (IEC62439-1), RSTP Guards
Management| Dual Software Image Support, TFTP, SFTP, SCP, LLDP (802.1AB),
LLDP-MED, SSHv2, HTTP, HTTPS, Traps, SNMP v1/v2/v3, Telnet, IPv6 Management ,
OPC UA Server
Diagnostics
| Management Address Conflict Detection, MAC Notification, Signal Contact, Device Status Indication, TCPDump, LEDs, Syslog, Persistent Logging on ACA, Port Monitoring with Auto-Disable, Link Flap Detection, Overload Detection, Duplex Mismatch Detection, Link Speed and Duplex Monitoring, RMON (1,2,3,9), Port Mirroring 1:1, Port Mirroring 8:1, Port Mirroring N:1, Port Mirroring N:2, System Information, Self-Tests on Cold Start, Copper Cable Test, SFP Management, Configuration Check Dialog, Switch Dump
Configuration
| Automatic Configuration Undo (roll-back), Configuration Fingerprint, Text- based Configuration File (XML), Backup config on a remote server when saving, Clear config but keep IP settings, BOOTP/DHCP Client with Auto-Configuration, DHCP Server: per Port, DHCP Server: Pools per VLAN, AutoConfiguration Adapter ACA21/22 (USB), HiDiscovery, USB-C Management support, Command Line Interface (CLI), CLI Scripting, CLI script handling over ENVM at boot, Full-featured MIB Support, Context-sensitive Help, HTML5 based Management
Security
| MAC-based Port Security, Port-based Access Control with 802.1X,
Guest/unauthenticated VLAN, Integrated Authentication Server (IAS), RADIUS
VLAN Assignment, Denial-of-Service Prevention, DoS Prevention Drop Counter,
VLAN-based ACL, Ingress VLAN-based ACL, Basic ACL, Access to Management
restricted by VLAN, Device Security Indication, Audit Trail, CLI Logging,
HTTPS Certificate Management, Restricted Management Access, Appropriate Use
Banner, Configurable Password Policy, Configurable Number of Login Attempts,
SNMP Logging, Multiple Privilege Levels, Local User Management, Remote
Authentication via RADIUS, User Account Locking, Password change on first
login
---|---
Time synchronisation| PTPv2 Transparent Clock two-step, PTPv2 Boundary Clock,
BC with Up to 8 Sync / s , 802.1AS, Buffered Real Time Clock, SNTP Client,
SNTP Server TSN 802.1Qbv Support
Industrial Profiles| EtherNet/IP Protocol, IEC61850 Protocol (MMS Server,
Switch Model), Modbus TCP, PROFINET Protocol
Miscellaneous| Digital IO Management, Manual Cable Crossing, Port Power Down
Ambient conditions
MTBF (Telecordia SR-332 Issue 3) @ 25°C| ****
4467842 h
---|---
Operating temperature| -40-+70 °C
Storage/transport temperature| -40-+70 °C
Relative humidity (non-condensing)| 1- 95 %
Mechanical construction
Dimensions (WxHxD) | 73 mm x 138 mm x 115 mm |
---|---|
Weight | 500 g |
Housing | PC-ABS |
Mounting | DIN Rail |
Protection class | IP30 |
Mechanical stability
IEC 60068-2-6
vibration
| 5 Hz … 8,4 Hz with 3,5 mm amplitude; 2 Hz … 13,2 Hz with 1 mm amplitude; 8,4
Hz … 200 Hz with 1 g; 13,2 Hz … 100 Hz with 0,7 g
---|---
IEC 60068-2-27 shock| 15 g, 11 ms duration
EMC interference immunity
EN 61000-4-2
electrostatic discharge (ESD)
| ****
6 kV contact discharge, 8 kV air discharge
---|---
EN 61000-4-3
electromagnetic field
| 10 V/m (80-2000 MHz); 5 V/m (2000-2700 MHz); 3 V/m (5100-6000 MHz)
EN 61000-4-4 fast
transients (burst)
| 2 kV power line, 2 kV data line
EN 61000-4-5 surge voltage| power line: 2 kV (line/earth) and 1 kV
(line/line); data line: 2 kV
EN 61000-4-6
Conducted Immunity
| 10 V (150 kHz-80 MHz)
EMC emitted immunity
EN 55022 | EN 55032 Class A |
---|---|
FCC CFR47 Part 15 | FCC 47CFR Part 15, Class A |
Approvals
Basis Standard | CE, FCC, EN61131, EN62368-1 |
---|---|
Safety of industrial control equipment | cUL61010 |
Scope of delivery and accessories
Accessories| AutoConfiguration Adapter ACA22-USB-C (EEC) 942239001; 6-pin
terminal block with screw lock (50 pieces) 943 845-013; 2-pin terminal block
with screw lock (50 pieces) 943 845-009; Industrial HiVision Network
Management Software 943 156-xxx
---|---
Scope of delivery| 1 × Device, 1 × Safety and general information sheet, 1 ×
Terminal block for supply voltage and signal contact, 1 × Terminal block for
the digital input depending on device variant, 2 × Ferrites with key depending
on device variant
Further Instructions
Product Documentation|
https://www.doc.hirschmann.com/index.html
---|---
Certificates|
https://www.doc.hirschmann.com/certificates.html
© 2022 Belden, Inc All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the
time of this publication, information and specifications described here in are
subject to error or omission and to change without notice, and the listing of
such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an “ASIS” basis,
with no representations or warranties, whether express, statutory or implied.
In no event will Belden be liable for any damages (including consequential,
indirect, incidental, special, punitive, or exemplary damages) whatsoever,
even if Belden has been advised of the possibility of such damages, whether in
an action under contract, negligence or any other theory, arising out of or in
connection with the use, or inability to use, the information or
specifications described herein.
All sales of Belden products are subject to Belden’s standard terms and
conditions of sale.
Belden believes this product to be in compliance with all applicable
environmental programs as listed in the data sheet. The information provided
is correct to the best of Belden’s knowledge, information and belief at the
date of its publication. This information is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself
or the one that it becomes a part of. The Product Disclosure is not to be
considered a warranty or quality specification. Regulatory information is for
guidance purposes only. Product users are responsible for determining the
applicability of legislation and regulations based on their individual usage
of the product.