HILTI PM 2-PG Green Plumb Laser Instruction Manual

June 3, 2024
HILTI

HILTI PM 2-PG Green Plumb Laser Instruction

HILTI-PM-2-PG-Green-Plumb-Laser-Instruction-prodact-
img

General safety instructions, measuring tools

WARNING  Read all safety precautions and other instructions. Measuring tools can present hazards if handled incorrectly. Failure to observe the safety instructions and other instructions can result in damage to the measuring tool and/or serious injury. Keep all safety precautions and instructions for future reference

  • Keep your workplace clean and well lit. Cluttered or poorly lit workplaces invite accidents.
  • Do not operate the product in explosive atmospheres, such as in the presence of flammable liquids, gases or dust. ٠ Keep children and other persons clear when the product is in use.

Use

the product only within its specified limits.

  • Comply with your national accident prevention regulations.
    Electrical safety

  • Do not expose the product to rain or moisture. Penetrating moisture can cause short circuits, electrical shock, burns or explosions.

  • Although the product is protected against the entry of moisture, it should be wiped dry before being put away in its transport container.
    Personal safety

  • Stay alert, watch what you are doing and use common sense when operating a measuring tool. Do not use a measuring tool while you are tired or under the influence of drugs, alcohol or medication. A moment of inattention while operating the measuring tool can result in serious personal injury.

  • Avoid unusual body positions.
    Keep proper footing and balance at all times.

  • Wear personal protective equipment. Wearing
    personal protective equipment reduces the risk of injury.

  • Do not render safety devices ineffective and do not remove information and warning notices.

  • Avoid accidental starting. Make sure that the measuring tool is switched off before connecting it to the battery and before picking it up or carrying it.

  • Use the product and accessories
    in accordance with these instructions and in the way specified for this special type of tool. Take the working conditions and the work to be performed into account. Use of products for applications different from those intended could result in hazardous situations. ٠ Do not lull yourself into a false sense of security and do not flout the safety rules for measuring tools, even if you are familiar with the measuring tool after using it many times. Carelessness can result in serious injury within a fraction of a second.

  • Do not use the measuring tool in the vicinity of medical devices. Using and handling the measuring tool
    Use the product and accessories only when they are in perfect working order.

Store

  • measuring tools out of reach of children when not in use.
  • Do not allow persons who are not familiar with the product or these instructions to operate it.
  • Measuring tools are dangerous in the hands of inexperienced persons.

Measuring

  • tools need care and attention. Check that moving parts operate satisfactorily and do not jam, and make sure that no parts are broken
  • Ikke skad batterier og ikke ta dem fra hverandre. Batterier kan eksplodere, brenne og begynne å lekke og skade personer

FCC-erklæring (gjelder for USA) / IC-erklæring (gjelder for Canada)

Dette apparatet har i tester overholdt grenseverdiene i avsnitt 15 i FCC- bestemmelsene for digitalt utstyr i klasse B. Disse grenseverdiene er beregnet for å gi tilstrekkelig beskyttelse mot forstyrrende stråling ved installasjon i boligområder. Apparater av denne typen genererer og bruker høye frekvenser og kan også utstråle dette. De kan derfor forårsake forstyrrelser på kringkastingsmottak hvis du ikke installerer og bruker apparatene I tråd med veiledningen Det kan imidlertid ikke gis garanti for at ikke forstyrrelser kan forekomme på enkelte installasjoner. Hvis dette utstyret fører til forstyrrelser på radio- eller tv-mottaket, noe som kan konstateres ved å skru av og på utstyret, anbefales brukeren å prøve å rette på forstyrrelsen på en eller flere av følgende måter:

  • Vri på eller bytt ut antennen.
  • Øk avstanden mellom apparatet og mottakeren.
  • Koble apparatet til et annet uttak enn der mottakeren er koblet til.
  • Konsulter forhandleren eller en erfaren radio/tv-spesialist. Denne anordningen er i samsvar med paragraf 15 i FCCbestemmelsene og RSS210 i ISED. Følgende betingelser gjelder for bruken:
  • Dette apparatet skal ikke forårsake skadelig stråling.
  • Apparatet må ta opp all stråling, inkludert stråling som forårsaker uønskede operasjoner.

Endringer og modifikasjoner som ikke uttrykkelig er tillatt av Hilti, kan begrense brukerens rett til å ta apparatet i bruk.

or damaged in such a way that the measuring tool might no longer function correctly. Have damaged parts repaired before using the measuring tool. Many accidents are caused by poorly maintained measuring tools

Do not
under any circumstances modify or tamper with the product. Changes or modifications not expressly approved by Hilti may restrict the user’s authorization to operate the product.

Check
the accuracy of the measuring tool before using it for important measurements, and if it has been dropped or subjected to other mechanical stresses.

Due to the measuring principle employed,
the results of measurements can be negatively affected by certain ambient conditions. These include, for example, the proximity of devices that produce strong magnetic or electro- magnetic fields, vibrations and temperature changes.

  • Rapidly changing measuring conditions can falsify the results.
  • When the product is brought into a warm environment from very cold conditions, or vice-versa, allow it to become acclimatized before use. Big differences in temperature
  • can lead to incorrect operation and incorrect results.
  • When adapters or accessories are used, make sure they are mounted securely.
  • The measuring tool is designed for the tough conditions of jobsite use, but as with other optical and electrical products (e.g. binoculars, spectacles, cameras) it must be handled with care.
  • The specified operating and storage temperatures must be observed. 1.2 Additional safety instructions for laser measuring tools
  • Laser radiation in excess of Class 2 can be emitted if the product is opened without correct procedure being followed. Have the product repaired only by Hilti Service.
  • Secure the area in which you will be taking measurements. While setting up the product, make sure that you do not direct the laser beam toward yourself or others. Laser beams should be projected well above or well below eye height
  •  Keep the laser exit window clean in order to avoid measurement errors.
  • Check the accuracy of the product before use and several times during use.

Readings

  • taken in the vicinity of reflective objects or surfaces, through panes of glass or similar materials can falsify the result of measurement.
  • Mount the product on a suitable holder or bracket or on a tripod, or set it on a smooth, level surface.  Do not work with surveyor’s staffs in the vicinity of high-voltage electricity cables.
  • Make sure that no other laser measuring tool that can influence your measurements is in use in the vicinity.
  • Do not permit the laser beam to project beyond the controlled area.

Additional safety instructions

  • Risk of injury by falling tools and/or accessories. Before starting work, check that the battery and installed accessories are secure

Electromagnetic compatibility

Although the product complies with the strict requirements of the applicable directives, Hilti cannot entirely rule out the possibility of interference to the product caused by powerful electromagnetic radiation, possibly leading to incorrect operation. Check the accuracy of the device by taking measurements by other means when working under such conditions, or if you are unsure. Likewise, Hilti cannot rule out the possibility of interference with other devices (e.g. aircraft navigation equipment).

Laser classification for Class 2 laser products

The product corresponds to Laser Class 2 in accordance with IEC ⁄ EN 60825-1:2014 and in accordance with CFR 21 § 1040 (FDA). This product may be used without need for further protective measures. Nevertheless, as with the sun, do not look directly into the light source. If you do inadvertently look into the laser beam, immediately close your eyes and move your head clear of the laser beam. Do not aim the laser beam at persons.

Careful handling a nd use of batteries

  • Remove the batteries from the product if it is to remain unused for a lengthy period of time. Batteries can corrode and self-discharge during prolonged storage
  • Make sure that batteries are inaccessible to children.
  • Do not mix old and new batteries. Always replace all batteries at the same time. Do not mix batteries of different makes or types.
  • Do not use damaged batteries.
  • Use only the battery type intended for this product. Use of other batteries may create a risk of injury and fire.
  • When replacing batteries, make sure that polarity is correct and that correct procedure is followed. There is a risk of explosion.
  • Do not allow batteries to overheat and do not expose them to fire. Batteries can explode and release toxic substances.
  • Do not attempt to charge non-rechargeable batteries.
  • Do not solder batteries into the product.
  • Do not discharge batteries by short-circuiting. Batteries can develop a leak, explode, catch fire and injure persons.
  • Do not damage batteries and do not attempt to take batteries apart. Batteries can develop a leak, explode, catch fire and injure persons.

FCC statement (applicable in US)/IC statement (applicable in Canada)

This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by taking the following measures

  • Re-orient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment to a power outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced TV/radio technician for assistance.
  • This device is in compliance with paragraph 15 of the FCC Regulations and RSS-210 of the ISED Regulations. Operation is subject to the

following two conditions

  • This device shall cause no harmful interference.
  • This device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by Hilti can restrict the user’s right to operate the device.

Further information

For more information on operation, technology, environment and recycling, follow this link: qr.Hilti.com/manual/?id=2341493

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HILTI User Manuals

Related Manuals