Honeywell SEM300 Communicator Installation Guide

June 3, 2024
Honeywell

Honeywell-LOGO

Honeywell SEM300 Communicator

![Honeywell [Communicator-fig1](https://manuals.plus/wp- content/uploads/2022/12/Honeywell-SEM300-Communicator-fig1.png)

SIMPLIFIED INSTRUCTIONS FROM YOUR FRIENDLY A.S.S. TEAM MEMBERS

We have compiled a much simpler installation manual for our customers in the hopes that we can alleviate all complications while installing your SEM300. Following this instruction guide will give you the best chance at setting up your Alarm.com communicator without ever having to reach out for any assistance. If you do have any problems or questions though, please feel free to email us at alarms@alarmsystemstore.com and we will do our best to assist you.
IMPORTANT: THIS GUIDE ASSUMES YOUR VISTA PANEL HAS KEYPAD ADDRESS 23 AVAILABLE. IF YOU NEED TO CHANGE THE SEM TO A DIFFERENT KEYPAD ADDRESS, CHECK OUR SECONDARY/TROUBLESHOOTING GUIDE FOR ADDRESSING THE SEM.

STEP GUIDE:

  1. PURCHASE ALARM.COM SERVICE AND FILL OUT REQUIRED FORMS
  2. PREPARE THE PANEL FOR INSTALLATION AND POWER DOWN
  3. WIRE THE SEM TO THE PANEL
  4. POWER THE SYSTEM UP AND ALLOW THE SEM TO SYNC TO THE PANEL
  5. CONFIRM COMMUNICATION WITH ALARM.COM THROUGH ALARM SYSTEM STORE
  6. ENJOY YOUR NEW ALARM.COM INTERACTIVE SERVICE
    TO SEE A VIDEO TUTORIAL OF THIS INSTALLATION PROCESS, SCAN THE QR CODE HERE:
  • STEP 1: BEFORE YOU START
1. PURCHASE AN ALARM.COM INTERACTIVE SERVICE FROM ALARM SYSTEM STORE AND COMPLETE THE INSTRUCTIONS IN THE ACTIVATION EMAIL.
2. ENSURE YOU HAVE ALL OF THE COMPONENTS NEEDED FOR YOUR SEM300 INSTALLATION:

Honeywell SEM300 Communicator-fig2

  • STEP 2: PREPARE THE SYSTEM FOR INSTALLATION AND POWER DOWN
    PREPARE THE SYSTEM

    • BEFORE POWERING DOWN THE SYSTEM:[[[[[[

    • EXECUTE 96
      Enter programming and execute
      96 to reset the account number and initialize the downloader. Then, exit programming via *99.

    • ENABLE THE KEYPAD ADDRESS
      The default keypad address the SEM uses is Keypad 8 Device Address 23. If this keypad address is disabled, the SEM and panel will not communicate properly. However, at first power-up, the SEM will attempt to enable this address automatically. [If unsuccessful, the address must be enabled manually via programming *196.

    • DISA[RM AND POWER DOWN THE PANEL[[

    1. Verify the panel is disarmed and clear of any alarms, troubles, or system faults.
    2. If you [do not know the current installer code, check the installer code at the panel before powering down the panel.[
    3. Then remove AC power and disconnect the backup battery to completely power down the system.
    • AFTER POWERING DOWN THE SYSTEM:
    • REMOVE THIRD PARTY COMMUNICATION
    • If there are any third-party communicators installed or a POTS line connected to the panel, remove them.
    • The SEM is not compatible with POTS, IP/GSM devices, or other third-party communicators. Therefore, the SEM should be the only communication device installed for alarm signaling to the monitoring station.
    • INSPECT FOR PERIPHERAL DEVICES
    1. Take inventory of all peripheral devices (wireless receivers, zone expanders, keypads, power [[[[supplies, etc.) wired to the system.
    2. Inspect the wiring to verify there are no loose ends or intermittent connections between the device and system. The presence of peripheral device issues can often cause the SEM installation process to take longer than expected.
  • STEP 3: CONNECTING THE SEM[[[[

    • WIRING
      Important: If you do not know what this means, disregard this sentence. Alternate wiring is required when using this device for ETL installations. (+12v wire from the SEM will go to the +12V terminal on the panel)

Honeywell SEM300 Communicator-fig3

  *  **TO WIRE THE PANEL:**
  * Connect panel terminal 4 (GND) to SEM GND, panel terminal 6 (GREEN: DATA IN FROM  

KEYPAD) to GREEN (OUT), and panel terminal 7 (YELLOW: KEYPAD DATA OUT) to YELLOW (IN).

  * Using the included red cable with the two-prong battery connector, connect the battery to both the SEM and the panel. For  a power limited circuit, ensure the fuse is inside the Vista panel.
  * Connect an Ethernet cable to the pre-installed Ethernet jack to utilize Dual-Path communication. Local network changes may be required before the broadband path activates.
  * Remove the snap-off plastics from the enclosure side at the desired locations, then route the cables around the internal strain relief walls and out the side of the enclosure.
  * Before completing the mounting, verify the wiring connections are secure and all internal components are in their proper [location.
  * Then close the enclosure by sliding the cover into the mounting points at the top of the enclosure base and then swinging[ down the cover to snap the thumb tabs into place.
  • STEP 4: POWER THE SYSTEM UP AND ALLOW THE SEM TO SYNC WITH THE PANEL
    • ZONE SCAN
    1. Reconnect the backup battery and restore AC power to the panel. On power-up, the SEM will enter programming to read the current installer code programmed at the panel, then perform a zone scan to read the existing zone information and  [settings programmed at the panel. During this process, the SEM will also automatically program-specific panel settings needed for the SEM to perform properly. The settings programmed are identified in INSTALLATION SETTINGS.
    2. The zone scan will automatically begin after the panel is powered up. On the keypad you will see a series of disarms and programming setting changes before seeing MODEM COMM on the screen. If you have a non-alpha keypad, the keypad  will show CC instead of MODEM COMM.
    • Zone scan (~5 minutes):
      Caution: Do not touch the panel or keypad.

[

    * If you do not see the MODEM COMM message appear on the keypad during zone scan and instead notice the keypad scrolling through each zone individually, the SEM is using an alternate zone scan method because it is unable to access the downloader
  3. When the zone scan is complete, the keypad will display the home screen. Your SEM300 is now finished uploading information to the Alarm.com account and is ready to use!
    * Zone scan complete:

[[[[

  • STEP 5: CONFIRM COMMUNICATION WITH ALARM.COM THROUGH ALARM SYSTEM STOREu
    • CONFIRM COMMUNICATION
    • Before completing the installation, verify that the SEM is fully in sync with the panel and communicating to Alarm.com by contacting alarms@alarmsystemstore.com and informing them that your SEM300 is ready to be verified and awaiting full activation.
    • You will receive an email back as soon as we can get to you to verify the signal and finish the activation.
      IF YOU HAVE A CENTRAL STATION ACCOUNT YOU ARE ACTIVATING AS WELL, YOU MAY NOW PROCEED WITH THE ACTIVATION AND TESTING FOR IT. OUR CUSTOMER SERVICE (alarms@alarmsystemstore.com) WILL INFORM YOU ON HOW TO TEST YOUR SYSTEM AND FINISH YOUR ACTIVATION.
      CONGRATULATIONS! YOU HAVE JUST INSTALLED YOUR SEM300! YOU ARE READY FOR STEP 6: ENJOY YOUR ALARM.COM INTERACTIVE PLAN