Wireless Alert PRO THP+
Wireless Alert PRO THP+
High-Accuracy Temperature &
Humidity Limit Alert Sensor
-30 °C to +80 °C Temperature Range0 %RH to 100 %RH Humidity Range
- High-accuracy temperature and humidity limit alert sensor from the FilesThruTheAir Wireless Alert PRO range
- Configurable high and low alert limits
- Monitor temperature and humidity in occupied spaces, storage areas and many other applications
- Wi-Fi-connected
- Get notified and view the latest status of your device using the FilesThruTheAir app
- Receive email alerts and scheduled status reports
- Flashing alert indicator
Download the FilesThruTheAir app for free
FilesThruTheAir’s WA-PRO-THP+ provides alert notifications when user-selected
high and low temperature or humidity limits are breached. Power this device
via its USB-C
socket and set it up using the free FilesThruTheAir app. Configuration options
include connection to a Wi-Fi network, temperature and humidity alert limit
selection, and notification options. Notifications can be pushed directly to
your smartphone or sent by email. Emailed scheduled summary reports detailing
minimum, maximum and average readings, power status, number of alerts, and
total time spent in the alert are also available. A quick look at the
FilesThruTheAir app dashboard will show the alert status
and last reported reading of any devices connected to your account.
Specification
Wireless Alert PRO TC Minimum| Typical Maximum| Unit
C ( F)
---|---|---
Measurement Range K Type (included)| 0 to +200’C (+32 to +392″F)
Measurement Range K Type| -200 to +1300°C (-328 to +2372°F)| °C (°F)
Measurement Range J Type| -200 to +1190°C (-328 to +2174°F)| °C (°F)
Measurement Range T Type| -200 to +390°C (-328 to +734°F)| °C (°F)
Measurement Resolution| 0.1 (0.1)| °C (°F)
Measurement Accuracy| | ±1 (0 to +200)
(±2 (+32 to +392))| | °C (range)
(°F (range))
Device Operating Temperature| -20 to +60°C (-4 to +140°F)| °C (`F)
Alert Levels| User-configurable, within the measurement range stated above|
Response Time| 1 minute|
Power Supply| USB-C 5V 1.0A|
VV i-Fi| WPA2/WPA3 Personal, WPA2 Enterprise (MSCHAP/PEAP, TTLS)
– 802.11 bgn (2.4GHz)|
Product Dimensions| L 61 (2.4) x W 29 (1.14) x D 13 (0.5)| mm (inches)
Probe Length| 100 (3.9)| mm (inches)
Cable Length| 1500 (59)| mm (inches)
What’s in the Box
Part Number | Description |
---|---|
WA-PRO-THP + | Temperature/Humidity Alert Sensor |
WA-PRO-BRACKET | Mounting Bracket and Fixing Screws |
WA-PRO-QSG | Quickstart guide |
USB-C-2M-WHT | USB-C Cable 2m |
Accessories Available
Part Number | Description |
---|---|
EL-SP-TH+ | Replacement Thermocouple Probe |
PSU-5VDC-USB-INTL-WHT | Power Supply |
WA-PRO-UPS 2 | UPS / Backup Battery |
WA-PRO-TC CAL | Calibration Certificate |
Wireless Alert PRO Range
Part Number | Description |
---|---|
WA-PRO-T | Wi-Fi-Connected Ambient Temperature Limit Alert (-20 °C to +60 °C) |
WA-PRO-T+ | Wi-Fi-Connected High-Accuracy Ambient Temperature Limit Alert (-20 |
°C to +60 °C)
WA-PRO-THP| Wi-Fi-Connected Temperature and Humidity Limit Alert (-30 °C to
+80 °C, 0 %RH to 100 %RH)
WA-PRO-THP+| Wi-Fi-Connected High-Accuracy Temperature and Humidity Limit
Alert (-30 °C to +80 °C, 0 %RH to 100 %RH)
WA-PRO-TP| Wi-Fi-Connected Temperature Limit Alert (-40 °C to +125 °C)
WA-PRO-TP+| Wi-Fi-Connected High-Accuracy Temperature Limit Alert (-40 °C to
+125 °C)
WA-PRO-TC| Wi-Fi-Connected Thermocouple Temperature Limit Alert (0 °C to 200
°C with supplied K Type Thermocouple)
WA-PRO-VAC| Wi-Fi-Connected Vaccine Temperature Limit Alert (-40 °C to +125
°C)
WA-PRO-ULT 2| Wi-Fi-Connected Ultra-Low Temperature Limit Alert (-100 °C to
+100 °C with supplied TType Thermocouple)
WA-PRO-ULT+ 2| Wi-Fi-Connected High-Accuracy Ultra-Low Temperature Limit Alert
(-100 °C to +100 °C with supplied T Type Thermocouple)
WA-PRO-420 2| Wi-Fi-Connected 4-20mA Limit Alert (4 mA to 20 mA)
- For more detailed specifications, refer to page 3 of this data sheet.
- Coming soon.
Specifications liable to change without prior warning.
SENSOR ACCURACY & INFORMATION
The sensor in this device is protected in storage and transit by a peelable protective film, this will need to be removed before the device is used.
|
---|---
Typical and maximal tolerance for temperature sensor in °C. EL| Typical and
maximal tolerance at 25°C for relative humidity.
-USB-2-LCD+
|
Typical accuracy of relative humidity measurements given in %RH for
temperatures 0 to 80°C.| Operating conditions
Long-term exposure to humidity levels outside of the ‘normal’ range may temporarily offset RH measurements (±3%RH after 60 hours). Once returned to less extreme conditions the device will slowly return to a calibration state.
When tracking changes in ambient conditions, the response time of the humidity
sensor in your Wireless Alert PRO is approximately 20 minutes to reach 90% of
the reading. However, if you are measuring step changes in humidity (for
example, if calibrating the product) it is advised that you leave the unit for
up to four hours to ensure that it has
enough time to settle at the new level.
It is worth remembering that the value of relative humidity is of course
sensitive to temperature variation. As an example, at a relative humidity of
~90%RH at ambient temperature, a variation in temperature of 1°C will result
in a change of up to -5%RH. Therefore when comparing multiple devices or
calibrating them, any temperature variations must be considered.
Other Wi-Fi-connected products from FilesThruTheAir™ FilesThruTheAir offer a
variety of sensors and data loggers.
Visit www.filesthrutheair.com to find out if
we have something to fit your application.
www.filesthrutheair.com/wireless-alert-
pro
FilesThruTheAir™ is a trademark of Corintech Ltd.
Ashford Mill, Station Road, Fordingbridge, Hampshire, SP6 1DZ, UK
Documents / Resources
|
files thru the air WA-PRO-THP+ High-Accuracy Temperature and Humidity Limit
Alert
Sensor
[pdf] User Guide
WA-PRO-THP, High-Accuracy Temperature and Humidity Limit Alert Sensor, WA-PRO-
THP High-Accuracy Temperature and Humidity Limit Alert Sensor
---|---
References
- Wireless Sensors & Data Loggers | Shop Now
- Wireless Alert PRO - Professional remote sensing for a variety of applications
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>