files thru the air WA-PRO-BRACKET Wireless Alert PRO TC Thermocouple Temperature Limit Alert Sensor User Guide

June 4, 2024
files thru the air

files thru - logo

Wireless Alert PRO TC
Thermocouple Temperature
Limit Alert Sensor

-200 °C to +1300 °C Temperature Range (0 °C to 200 °C with the supplied K-Type probe)

files thru the air WA-PRO-BRACKET Wireless Alert PRO TC Thermocouple
Temperature Limit Alert Sensor

  • Thermocouple temperature limit alert sensor from the FilesThruTheAir Wireless Alert PRO range
  • Configurable high and low-temperature limits
  • Monitor ultra-low temperature storage, boiler operation, and many other applications
  • Wi-Fi-connected
  • Get notified and view the latest status of your device using the FilesThruTheAir app
  • Receive email alerts and scheduled status reports
  • Flashing alert indicator

Download the FilesThruTheAir app for free

FilesThruTheAir’s WA-PRO-TC provides alert notifications when user-selected high and low-temperature limits are breached. Power this device via its USB-C socket and set it up using the free FilesThruTheAir app. Configuration options include connection to a Wi-Fi network, temperature limit selection, and notification options. Notifications can be pushed directly to your smartphone or sent by email.
Emailed scheduled summary reports detailing minimum, maximum and average temperature, power status, number of alerts, and total time spent in the alert are also available. A
a quick look at the FilesThruTheAir app dashboard will show the alert status and last reported reading of any devices connected to your account.

Specification

Wireless Alert PRO TC Minimum| Typical        Maximum| Unit
C ( F)
---|---|---
Measurement Range K Type (included)| 0 to +200’C (+32 to +392″F)
Measurement Range K Type| -200 to +1300°C (-328 to +2372°F)| °C (°F)
Measurement Range J Type| -200 to +1190°C (-328 to +2174°F)| °C (°F)
Measurement Range T Type| -200 to +390°C (-328 to +734°F)| °C (°F)
Measurement Resolution| 0.1 (0.1)| °C (°F)
Measurement Accuracy| | ±1 (0 to +200)
(±2 (+32 to +392))| | °C (range)
(°F (range))
Device Operating Temperature| -20 to +60°C (-4 to +140°F)| °C (`F)
Alert Levels| User-configurable, within the measurement range stated above|
Response Time| 1 minute|
Power Supply| USB-C 5V 1.0A|
VV i-Fi| WPA2/WPA3 Personal, WPA2 Enterprise (MSCHAP/PEAP, TTLS)
– 802.11 bgn (2.4GHz)|
Product Dimensions| L 61 (2.4) x W 29 (1.14) x D 13 (0.5)| mm (inches)
Probe Length| 100 (3.9)| mm (inches)
Cable Length| 1500 (59)| mm (inches)

What’s in the Box

Part Number Description
WA-PRO-TC Thermocouple Limit Alert Sensor
WA-PRO-BRACKET Mounting Bracket and Fixing Screws
WA-PRO-QSG Quickstart guide
USB-C-2M-WHT USB-C Cable 2m

Accessories Available

Part Number Description
EL-SP-TC Replacement Thermocouple Probe
PSU-5VDC-USB-INTL-WHT Power Supply
WA-PRO-UPS 2 UPS / Backup Battery
WA-PRO-TC CAL Calibration Certificate

Wireless Alert PRO Range

Part Number Description
WA-PRO-T Wi-Fi-Connected Ambient Temperature Limit Alert (-20 °C to +60 °C)
WA-PRO-T+ Wi-Fi-Connected High-Accuracy Ambient Temperature Limit Alert (-20

°C to +60 °C)
WA-PRO-THP| Wi-Fi-Connected Temperature and Humidity Limit Alert (-30 °C to +80 °C, 0 %RH to 100 %RH)
WA-PRO-THP+| Wi-Fi-Connected High-Accuracy Temperature and Humidity Limit Alert (-30 °C to +80 °C, 0 %RH to 100 %RH)
WA-PRO-TP| Wi-Fi-Connected Temperature Limit Alert (-40 °C to +125 °C)
WA-PRO-TP+| Wi-Fi-Connected High-Accuracy Temperature Limit Alert (-40 °C to +125 °C)
WA-PRO-TC| Wi-Fi-Connected Thermocouple Temperature Limit Alert (0 °C to 200 °C with supplied K Type Thermocouple)
WA-PRO-VAC| Wi-Fi-Connected Vaccine Temperature Limit Alert (-40 °C to +125 °C)
WA-PRO-ULT 2| Wi-Fi-Connected Ultra-Low Temperature Limit Alert (-100 °C to +100 °C with supplied TType Thermocouple)
WA-PRO-ULT+ 2| Wi-Fi-Connected High-Accuracy Ultra-Low Temperature Limit Alert (-100 °C to +100 °C with supplied T Type Thermocouple)
WA-PRO-420 2| Wi-Fi-Connected 4-20mA Limit Alert (4 mA to 20 mA)

  1. Thermocouple accuracy not included. Note: Thermocouple probe tips must be kept electrically isolated. If metal-sheathed probes are used, check that the sheath is isolated from the probe junction. If it is not or you are using an unsheathed probe, ensure that the probe tip is insulated.
  2. Coming soon.
    Specifications liable to change without prior warning.

Other Wi-Fi-connected products from FilesThruTheAir™ FilesThruTheAir offer a variety of sensors and data loggers.
Visit www.filesthrutheair.com to find out if we have something to fit your application.

files thru the air WA-PRO-BRACKET Wireless Alert PRO TC Thermocouple
Temperature Limit Alert Sensor - icon 4files thru -
logowww.filesthrutheair.com/wireless-alert- pro
FilesThruTheAir™ is a trademark of Corintech Ltd.
Ashford Mill, Station Road, Fordingbridge, Hampshire, SP6 1DZ, UK

Documents / Resources

| files thru the air WA-PRO-BRACKET Wireless Alert PRO TC Thermocouple Temperature Limit Alert Sensor [pdf] User Guide
WA-PRO-BRACKET, Wireless Alert PRO TC Thermocouple Temperature Limit Alert Sensor, WA-PRO-BRACKET Wireless Alert PRO TC Thermocouple Temperature Limit Alert Sensor
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

files thru the air User Manuals

Related Manuals