Introduction

The Midas-M Sensor Cartridge enables the detection of a wide range of asphyxiant, toxic, flammable, pyrophoric, corrosive, and oxidizer (including Oxygen) gases.
The plug & play Sensor Cartridge is located inside the detector’s chassis.

CAUTION
Failure to observe the following precautions can cause injury to persons or damage to property:

  • When the Midas-M Sensor Cartridge reaches the end of its life, it should be disposed of by local regulations.

  • Do not use cleaning solvents or abrasives to clean the Sensor Cartridge.

  • Do not attempt to modify the product in any way from the manufacturer’s design or specification.
    Warranty will be void and malfunction of the gas detector may result.

  • Use only genuine spare parts and accessories with Midas-M. Malfunctions may result if non-standard parts are used.

  • Installation must be by the recognized standards of the appropriate authority in the country concerned.
    For Europe, see EN60079-14, EN60079- 29-2, and EN61241-14. For installations in North
    America, the National Electrical Code (NFPA 70) should be strictly observed. All the appropriate local and national regulations should be observed.

NOTE: If the customer breaks down the sensor cartridge by disassembling, modifying, careless use (physical and chemical damage), or other unauthorized alteration, the quality is not guaranteed and is excluded from the free replacement.

What’s in the Box

  • 1 Sensor Cartridge
  • 1 battery module, only when the BiAS sensor is included in the cartridge
  • 1 Quick Reference Guide

Overview

Mounting the Sensor Cartridge

  1. Turn the power off

  2. Open the door and remove the BiAS battery module and the two plug caps.

  3. Align the Sensor cartridge pins with the socket in the sensor cartridge chamber and then push the sensor cartridge gently until fully seated.

  4. Close the door.
    Press the ‘O’ button to clear the “Detect New Cartridge ” message.

    • Confirm that the green LED is flashing, and that the yellow and red LEDs are off.
    • Confirm the display shows a concentration of zero (as appropriate).

Warranty

Midas-M sensor cartridges carry a 12 month (1 year) warranty from switch- on/installation or up to 18 months from the date of shipment from Honeywell Analytics, whichever is less, provided this takes place before the “Activate Before” date on the cartridge. Pro-rata after “Activate Before”/install by date.
The oxygen sensor cartridge is guaranteed to operate satisfactorily for the period described above and will be replaced at no charge within that period only if it will not provide a correct reading after calibration by Authorized Service personnel. Physical or chemical damage, resulting from exposure to improper elements, is not covered.

The combustible (LEL) sensor cartridge is guaranteed to operate satisfactorily for the period described above. If it will not provide a correct reading after calibration by Authorized

Service personnel, it will be replaced at no charge within that period. This guarantee is void if it has been contaminated by some unusual substance, including but not limited to, water and/or other liquids, oily compounds, corrosives, silicones, lead vapors, extremely high concentrations of combustible gases, and various particulates which may inhibit gas flow to the sensor cartridge element.
The toxic sensor cartridges are guaranteed to operate satisfactorily for the period described above. They will be replaced at no charge within that period only if they will not provide a correct reading after calibration by Authorized Service personnel, and only if the sensor cartridge membranes exhibit no physical or chemical damage resulting from exposure to improper substances.
Note that the Midas-0M sensor cartridge stores an electronic history of each individual sensor cartridge’s manufacture,warranty and calibration activity that is accessible by authorized Service personnel.

Contact Us

Americas
Honeywell Analytics
405 Barclay Boulevard
Lincolnshire, IL 60069
Tel: +1 847 955 8200
Toll free: +1 800 538 0363
Fax: +1 847 955 8208
detectgas@honeywell.com

Europe, Middle East, and Africa
Life Safety Distribution
AG(LSD)
Javastrasse 2
8604 Hegnau
Switzerland
Tel: +41 (0)44 943 4300
Fax: +41 (0)44 943 4398
gasdetection@honeywell.com

Asia Pacific, India.
Honeywell Analytics Asia Pacific, Co., Ltd.
7F SangAm IT Tower,
434 Worldcup Buk-ro, Mapo-gu,
Seoul 03922, South Korea
Tel: +82 (02 6909 0300
Fax: +82 (02 2025 0388
India Tel: +91 124 4752 700
Analytics.ap@honeywell.com

Mainland China
Honeywel Industrial Safety Gas Detectors
Building#L, 555 Huanke Road Zhang Jiang
Hi-Tech Park Pudong New Area Shanghai
201203, China
Tel: 021-80386800
Fax: 021-60246070
gaschina@honeywelL.com

Taiwan
Honeywell Taiwan Ltd
6F-2, No.8, ZiQiang S. Road, Jubei City,
30264 Taiwan
Tel:+886-3-5169284
Fax: +886-3-5169339
analytics.tw@honeywell.com

Manuals and other information about this product are available at:
www.honeywellanalytics.com/en/products/Midas-M

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Honeywell User Manuals

Related Manuals