Installation Instructions for the Global Safety Limit Switch (GSS Series)

WARNING
IMPROPER INSTALLATION

  • Consult with local safety agencies and their requirements when designing a machine-control link, interface, and all control elements that affect safety.
  • Strictly adhere to all installation instructions.

Failure to comply with these instructions could result in death or serious injury.

MOUNT, WIRE AND SEAL SWITCH

WARNING
IMPROPER OPERATION

  • Ensure switch actuator achieves sufficient travel for positive opening of normally closed (NC) contacts to occur.

Failure to comply with these instructions could result in death or serious injury.

  1. Refer to:
    • Page 3 for adjustments.
    • Page 4 for EN 50041 wiring configurations for each switch code.(Ag=silver contacts, Au=gold-plated contacts)
    • Pages 5 and 6 for specific travel distances for each switch code, and specifications.
    • Page 7 proper application of limit switches, and switch mounting dimensions.
  2. Perform adjustments (if desired):
    • Head orientation (Figure 1).
    • Actuation direction (Figure 2).
    • Side rotary switches with 90° positive drive levers (catalog listings ending in A1A, A1B, A5A, A5B) (Figure 3):
    • Ensure flats of switch shaft engage groove in actuator lever.
    • Tighten locking screw (A) until tab (B) no longer moves.
  3. Mount switch using four M5 or #10 screws. Torque screws to 4,9 Nm to 5,9 Nm [43 in-lb to 52 in-lb].
  4. Remove screws on cover plate.
  5. Connect stranded wire (0,75 mm2 to 2,5 mm2, 18-14 AWG) or solid wire (0,75 mm2 to 1,5 mm2, 18-16 AWG) to connector terminals (use 90 °C wire when ambient temperature is over 75 °C). Torque switch terminal screws to 0,8 Nm to 1,0 Nm [7 in-lb to 9 in-lb].
  6. Seal conduit opening according to instructions in PK 80112.
  7. Reassemble cover plate, and torque cover screws to 0,5 Nm [4.4 in-lb].

Honeywell-GSS-Series-GSAA01A1B-General-Purpose-Safety-
Switches-01

| | | Contact Closed
---|---|---|---
| | | Contact Open
| | | Differential Travel
CAT| Catalog Listing
FP| Free Position
OP1| Operating Position 1
OP2| Operating Position 2
PO1| Positive Opening 1

to IEC 947-5-1

PO2| Positive Opening 2

to IEC 947-5-1

DT1| Differential Travel 1
DT2| Differential Travel 2
OT| Over Travel
MOF| Maximum Operating

Force

MDF| Maximum Disconnect Force

Honeywell-GSS-Series-GSAA01A1B-General-Purpose-Safety-
Switches-02

| ANGULAR TRAVEL (°)| CARRERA ANGULAR (°)| WINKELWEG (°)|
---|---|---|---|---
| COURSE ANGULAIRE (°)| CORSA ANGOLARE (°)| PERCURSO ANGULAR (°)|

Ag

| CAT

Au

| FP| OP1| OP2| PO1| PO2| DT1| DT2| OT| MOF| MDF
GSA 01 A| GSA 07 A| 0| 26| –| 55| –| 12| –| 85| 0,33 N m [2.9 in lb]| 0,385 N m [3.4 in lb]
GSA 03 A GSA 42 A GSA 44 A

GSA 46 A

| GSA 33 A GSA 43 A GSA 45 A

GSA 47 A

| 0| 26| 38| 38| –| –| –| 85| 0,33 N m [2.9 in lb]| 0,385 N m [3.4 in lb]
GSA 04 A| GSA 34 A| 0| 38| 26| 50| –| –| –| 85| 0,33 N m [2.9 in lb]| 0,385 N m [3.4 in lb]
GSA 06 A GSA 40 A| GSA 36 A GSA 41 A| 0| 26| –| 38| –| –| –| 85| 0,33 N m [2.9 in lb]| 0,385 N m [3.4 in lb]
GSA 20 A| GSA 22 A| 0| 26| –| 55| –| 12| –| 85| 0,33 N m [2.9 in lb]| 0,400 N m [3.5 in lb]
GSA 21 A| GSA 28 A| 0| 27| 42| 55| 70| 7| 6| 85| 0,33 N m [2.9 in lb]| –

| CAM TRAVEL (mm)| CARRERA DE LA LEVA (mm)| NOCKENLAUFWEG (mm)|
---|---|---|---|---
| COURSE DE CAME (mm)| CORSA CAMMA (mm)| PERCURSO DO CAME (mm)|

Ag

| CAT

Au

| FP| OP1| OP2| PO1| PO2| DT1| DT2| OT| MOF| MDF
GSA 01 A| GSA 07 A| -3,6| 20| –| 56| –| 12| –| –| 9,7 N (2.2 lb)| 11,4 N [2.6 lb]
GSA 03 A GSA 42 A GSA 44 A GSA 46 A| GSA 33 A GSA 43 A GSA 45 A GSA 47 A| -3,6| 20| 32| 32| –| –| –| –| 9,7 N [2.2 lb]| 11,4 N [2.6 lb]
GSA 04 A| GSA 34 A| -3,6| 32| 20| 45| –| –| –| –| 9,7 N [2.2 lb]| 11,4 N [2.6 lb]
GSA 06 A

GSA 40 A

| GSA 36 A

GSA 41 A

| -3,6| 20| –| 32| –| –| –| –| 9,7 N [2.2 lb]| 11,4 N [2.6 lb]
GSA 20 A| GSA 22 A| -3,6| 20| –| 56| –| 12| –| –| 9,7 N [2.2 lb]| 11,8 N [2.7 lb]
GSA 21 A| GSA 28 A| -3,6| 20| 38,5| 56| 74,5| 7| 8,5| –| 9,7 N [2.2 lb]| —
GSA 01 C| GSA 07 C| 11,3| 15| –| 18,3| –| 1,8| –| –| 9,3 N [2.1 lb]| 15,6 N [3.5 lb]
GSA 03 C GSA 42 C GSA* 44 C

GSA* 46 C

| GSA 33 C GSA 43 C GSA* 45 C

GSA* 47 C

| 11,3| 15| 16,8| 18,3| –| –| –| –| 9,3 N [2.1 lb]| 15,6 N [3.5 lb]
GSA 04 C| GSA 34 C| 11,3| 16,8| 15| 20,3| –| –| –| –| 9,3 N [2.1 lb]| 15,6 N [3.5 lb]
GSA 06 C GSA 40 C| GSA 36 C GSA 41 C| 11,3| 15| –| 18,3| –| –| –| –| 9,3 N [2.1 lb]| 15,6 N [3.5 lb]
GSA 20 C| GSA 22 C| 11,3| 15| –| 18,3| –| 1,8| –| –| 9,3 N [2.1 lb]| 21,4 N [4.8 lb]
GSA 21 C| GSA 28 C| 11,3| 15| 16,9| 18,3| 20,3| 1,4| 1,4| –| 9,3 N [2.1 lb]| 15,6 N [3.5 lb]
GSA 01 D| GSA 07 D| 9,1| 20| –| 29,1| –| 4,1| –| –| 5,5 N [1.2 lb]| 7,0 N [1.6 lb]
GSA 03 D GSA 42 D GSA 44 D GSA 46 D| GSA 33 D GSA 43 D GSA 45 D GSA 47 D| 9,1| 20| 24,1| 29,1| –| –| –| –| 5,5 N [1.2 lb]| 7,0 N [1.6 lb]
GSA 04 D| GSA 34 D| 9,1| 24,1| 20| 33,2| –| –| –| –| 5,5 N [1.2 lb]| 7,0 N [1.6 lb]
GSA* 06 D

GSA* 40 D

| GSA* 36 D

GSA* 41 D

| 9,1| 20| –| 29,1| –| –| –| –| 5,5 N [1.2 lb]| 7,0 N [1.6 lb]
GSA 20 D| GSA 22 D| 9,1| 20| –| 29,1| –| 4,1| –| –| 5,5 N [1.2 lb]| 9,6 N [2.2 lb]
GSA 21 D| GSA 28 D| 9,1| 20| 25,5| 29,1| 31,1| 3,7| 3,7| –| 5,5 N [1.2 lb]| 7,0 N [1.6 lb]

PIN TRAVEL [mm] CARRERA DEL RODILLO[mm] STIFTLAUFWEG [mm] COURSE DE BROCHE [mm] CORSA PERNO [mm] PERCURSO DO PINO [mm]

Ag| CAT
Au| FP| OP1| OP2| PO1| PO2| DT1| DT2| OT| MOF| MDF
---|---|---|---|---|---|---|---|---|---|---|---
GSA 01 B| GSA 07 B| 37,5| 35| –| 33| –| 0,9| –| 30,5| 16 N [3.6 lb]| 27 N [6.0 lb]
GSA 03 B GSA 42 B GSA 44 B GSA 46 B| GSA 33 B GSA 43 B GSA 45 B GSA 47 B| 37,5| 35| 34| 33| –| –| –| 30,5| 16 N [3.6 lb]| 27 N [6.0 lb]
GSA 04 B| GSA 34 B| 37,5| 34| 35| 32| –| –| –| 30,5| 16 N [3.6 lb]| 27 N [6.0 lb]
GSA* 06 B

GSA* 40 B

| GSA* 36 B

GSA* 41 B

| 37,5| 35| –| 33| –| –| –| 30,5| 16 N [3.6 lb]| 27 N [6.0 lb]
GSA 20 B| GSA 22 B| 37,5| 35| –| 33| –| 0,9| –| 30,5| 16 N [3.6 lb]| 37 N [8.2 lb]
GSA 21 B| GSA 28 B| 37,5| 35| 33,8| 33| 31,8| 0,8| 0,8| 30,5| 16 N [3.6 lb]| 27 N [6.0 lb]
GSA 01 C| GSA 07 C| 50,5| 48| –| 46| –| 0,9| –| 43,5| 16 N [3.6 lb]| 27 N [6.0 lb]
GSA 03 C GSA 42 C GSA* 44 C

GSA* 46 C

| GSA 33 C GSA 43 C GSA* 45 C

GSA* 47 C

| 50,5| 48| 47| 46| –| –| –| 43,5| 16 N [3.6 lb]| 27 N [6.0 lb]
GSA 04 C| GSA 34 C| 50,5| 47| 48| 45| –| –| –| 43,5| 16 N [3.6 lb]| 27 N [6.0 lb]
GSA 06 C GSA 40 C| GSA 36 C GSA 41 C| 50,5| 48| –| 46| –| –| –| 43,5| 16 N [3.6 lb]| 27 N [6.0 lb]
GSA 20 C| GSA 22 C| 50,5| 48| –| 46| –| 0,9| –| 43,5| 16 N [3.6 lb]| 37 N [8.2 lb]
GSA 21 C| GSA 28 C| 50,5| 48| 46,8| 46| 44,8| 0,8| 0,8| 43,5| 16 N [3.6 lb]| 27 N [6.0 lb]
GSA 01 D| GSA 07 D| 65,2| 61| –| 56,9| –| 1,7| –| 52| 9,5 N [2.1 lb]| 12 N [2.7 lb]
GSA 03 D GSA 42 D GSA 44 D GSA 46 D| GSA 33 D GSA 43 D GSA 45 D GSA 47 D| 65,2| 61| 59,1| 56,9| –| –| –| 52| 9,5 N [2.1 lb]| 12 N [2.7 lb]
GSA 04 D| GSA 34 D| 65,2| 59,1| 61| 55| –| –| –| 52| 9,5 N [2.1 lb]| 12 N [2.7 lb]
GSA* 06 D

GSA* 40 D

| GSA* 36 D

GSA* 41 D

| 65,2| 61| –| 56,9| –| –| –| 52| 9,5 N [2.1 lb]| 12 N [2.7 lb]
GSA 20 D| GSA 22 D| 65,2| 61| –| 56,9| –| 1,7| –| 52| 9,5 N [2.1 lb]| 16,4 N [3.7 lb]
GSA 21 D| GSA 28 D| 65,2| 61| 58,6| 58| 57,4| 1,6| 1,6| 52| 9,5 N [2.1 lb]| 12 N [2.7 lb]
GSA 01 R| GSA 07 R| 44,6| 42,1| –| 40,1| –| 0,9| –| 37,6| 16 N [3.6 lb]| 27 N [6.0 lb]
GSA 03 R GSA 42 R GSA* 44 R

GSA* 46 R

| GSA 33 R GSA 43 R GSA* 45 R

GSA* 47 R

| 44,6| 42,1| 41,1| 40,1| –| –| –| 37,6| 16 N [3.6 lb]| 27 N [6.0 lb]
GSA 04 R| GSA 34 R| 44,6| 41,1| 42,1| 39,1| –| –| –| 37,6| 16 N [3.6 lb]| 27 N [6.0 lb]
GSA 06 R GSA 40 R| GSA 36 R GSA 41 R| 44,6| 42,1| –| 40,1| –| –| –| 37,6| 16 N [3.6 lb]| 27 N [6.0 lb]
GSA 20 R| GSA 22 R| 44,6| 42,1| –| 40,1| –| 0,9| –| 37,6| 16 N [3.6 lb]| 37 N [8.2 lb]
GSA 21 R| GSA 28 R| 44,6| 42,1| 40,9| 40,1| 38,9| 0,8| 0,8| 37,6| 16 N [3.6 lb]| 27 N [6.0 lb]

Designation and Utilization Category| Rated Operational Current Ie [A] at Rated Operational Voltage Ue [V]| VA Rating
---|---|---
| 120 V| 240 V| 380 V| 480 V| 500 V| 600 V| Make| Break
AC15| A600| 6 A| 3 A| 1,9 A| 1,5 A| 1,4 A| 1,2 A| 7200| 720
AC15| A300| 6 A| 3 A| –| –| –| –| 7200| 720
DC13| Q300| 0,55 A| 0,27 A| –| –| –| –| 69| 69
Rated Thermal Current [Ith]                                          10 A
Gold-plated Contacts                                                  1 V, 10 mA min.; 50 V, 100 mA max.
Rated Impulse Withstand [Uimp]                                   2500 V
Rated Insulation Voltage [Ui]                                       300 V, 500 V, 600 V

Maximum Fuse Rating                                                10 A quick acting

Sealing IP66/67; Enclosure Type 1, 4, 12, 13
Operating Temperature Range                                   -25 °C to 85 °C [-13 °F to 185 °F]

Storage Temperature Range                                      -40 °C to 85 °C [-40 °F to 185 °F]

MCTF [Mechanical Life]                                              >1,000,000 cycles with single-sided confidence limit of 100 %

MCTF [Electrical Life]

25,000 cycles with single-sided confidence limit of 100 %

Highest SIL Capability:                                                SIL3 (HFT:1), IEC 61508-2: 2010

Proof Test Interval:                                                      1 Year

Complies with:

  • Machinery Directive 89/392/EEC [as amended by Directive 91/368/EEC]
  • EN60947-5-1 / IEC60947-5-1

Honeywell-GSS-Series-GSAA01A1B-General-Purpose-Safety-
Switches-03

WARRANTY/REMEDY

Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.

While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.

Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

E-mail: info.sc@honeywell.com
Internet: sensing.honeywell.com

Phone and Fax:
Asia Pacific +65 6355-2828
+65 6445-3033 Fax
Europe +44 [0] 1698 481481
+44 [0] 1698 481676 Fax
Latin America +1-305-805-8188
+1-305-883-8257 Fax
USA/Canada +1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Honeywell User Manuals

Related Manuals