HURCO TECHNOLOGIES HHTP10500H Old Faithful Pumper Hydrostatic Test Pump User Guide
- September 25, 2024
- HURCO TECHNOLOGIES
Table of Contents
HURCO TECHNOLOGIES HHTP10500H Old Faithful Pumper Hydrostatic Test Pump
Product Information
Specifications
- Product Name: Old Faithful Pumper
- Type: Hydrostatic Test Pump
- Manufacturer: Hurco Technologies, Inc.
- Website:www.hurcotech.com
- Contact: 1-800-888-1436
Product Usage Instructions
Important Safety Information
- WARNING! READ ALL OPERATING MANUALS BEFORE THE OPERATION OF EQUIPMENT. GENERAL SAFETY INFORMATION.
- SAFETY FIRST! Hydrostatic pressure testing of water mains can be extremely dangerous if not done properly.
- Follow all safety guidelines and use common sense when operating a hydrostatic test pump. Never take chances; it could cost you your life.
Operating Instructions – Hydrostatic Pressure Testing Steps
- Fill the water main following the recommendations of the American Water Works Association (AWWA).
- These recommendations can be purchased online at the AWWA website at www.awwa.org. Also, refer to the pipe manufacturer’s recommendations.
- WARNING! It is important to get as much air out as possible to avoid damage and safety hazards.
Connecting Your Old Faithful Pumper to the Water Main
- Read all warnings displayed on the Old Faithful Pumper before operation.
- WARNING! Do not run your Old Faithful Pumper without proper understanding and connection.
Hydrostatic Testing the Water Main
- Ensure all connections are properly made and that the water main is filled to eliminate trapped air.
- Follow the steps provided in the manual to conduct the test safely and accurately.
FAQ
Q: How do I contact customer support for questions regarding the manual or hydrostatic testing?
A: You can call customer support at 1-800-888-1436 for any queries related to the manual or hydrostatic testing.
Welcome
- Thank you for purchasing Hurco’s Old Faithful Pumper hydrostatic test pump. Like its namesake, the “Old Faithful” line of hydrostatic test pumps are engineered for reliability and durability, with low-cost maintenance and nearly “wear-free” operation.
- Hurco revolutionized the manifold system back in the 1980s when we first introduced our hydrostatic test pumps. The manifold system replaces many of the traditional pipe fittings it would take to build the hydrostatic test pump.
- This eliminated as many as 21 potential leak points and made maintenance and repairs much easier.
Old Faithful Pumper:
- Available in two models. 10 GPM @ 500 PSI and 23 GPM @ 700 PSI, both featuring Annovi Reverberi Pumps.
- Capable of handling chlorine solutions up to 10%.
- Bypass relief valve take pressure off the pump during start up and safeguards against valve seat sticking that could cause pump damage.
- Utilizes a damper diaphragm to help eliminate damage to the pump caused by pressure spikes.
- Hurco Technologies, Inc. would like to take this opportunity to welcome you as a new customer and user of the Old Faithful Pumper. You have just purchased the best hydrostatic test pump available.
- The Old Faithful Pumper is simple to use and will provide you with years of service.
- This manual, along with the AR Medium or High-Pressure Diaphragm Pumps manuals, will take you through the step-by-step procedures for using the Old Faithful Pumper.
- We use simple-to-understand instructions and photos to assist you in learning how to get the best results from your Old Faithful Pumper. Please follow each step completely to ensure maximum performance from your Old Faithful Pumper.
- Your Old Faithful Pumper will give you many years of service if you take care of it as you would any expensive piece of equipment.
- The Old Faithful Pumper is rugged and built to last. It will withstand the demands of your jobsite; however, is not abuse-proof!
- Be sure to assign the use of your Old Faithful Pumper to a competent worker who will take care of it.
- In this manual, we will be giving you suggestions on basic line hydrostatic pressure testing activities. As a general rule, these suggestions are based on testing that was done on the Old Faithful hydrostatic test pump and methods commonly used in the field.
- Each community or engineering firm may have their own requirements for hydrostatic pressure testing of their water lines.
- You should always follow their instructions for testing.
- However, regardless of the instructions you are using, always keep in mind safety. Hydrostatic testing can be extremely dangerous if it is done incorrectly.
- If you have any questions regarding this manual or hydrostatic testing in general, please call and ask for customer support at 1-800-888-1436.
- Sincerely,
- Lyndon J. Hurley
- President, Hurco Technologies, Inc.
- WARNING: Never do hydrostatic pressure testing or use the Old Faithful Pumper in temperatures below 45° F. Call 1-800-888-1436 for more information.
Important Safety Information
- WARNING! READ ALL OPERATING MANUALS BEFORE OPERATION OF EQUIPMENT GENERAL SAFETY INFORMATION SAFETY FIRST!
- Hydrostatic pressure testing of water mains can be extremely dangerous if not done properly. You must follow all the safety guidelines and use common sense when operating a hydrostatic test pump.
- Never take chances; it could cost you your life!
- WARNING: This pump is for pumping water only. Pumping other fluids can be dangerous causing personal injury and will void all warranties.
- ALWAYS wear protective clothing and safety glasses when operating machinery.
- NEVER service or repair the Old Faithful Pumper while running. Allow the engine to cool.
- ALWAYS shut off the engine and do not smoke when fueling the Old Faithful Pumper.
- ALWAYS release all pressure within the pump before servicing any component.
- NEVER operate a gasoline engine in an enclosed area. Be sure the area is well-ventilated
- NEVER pump at pressures higher than the maximum recommended pressures for the pump. (see Specifications in Hypro Manual)
- NEVER operate your Old Faithful Pumper in temperatures below 45° F. Doing so will damage the pump and can be extremely dangerous, causing serious injury or death.
- NEVER make a connection to your water main with old, worn, or inferior parts. These parts can break under pressure and cause serious injury or death.
- ALWAYS secure all hoses and fittings. These fittings and hoses are under pressure and if there is a failure, they can “whip,” causing serious injury or death.
- ALWAYS wear protective clothing and eye protection. When working with chlorine, wear protective clothing as recommended by the chlorine manufacturer.
- Periodically inspect system components. Perform routine maintenance as required
- Refer to the AR Medium or High-Pressure Diaphragm Pumps manuals for additional safety information.
- WARNING: Your life depends on every move you make when hydrostatic testing. Don’t leave anything to chance. Check every detail of your Old Faith Pumper and all connections before starting the engine.
Operating Instructions
Hydrostatic Pressure Testing Steps
- Hydrostatic pressure testing will help you quickly determine the quality of installation of your water mains. Done right, hydrostatic pressure testing is fast and safe.
- Please take the time to completely read this manual and understand the steps for safely testing your water mains.
Old Faithful Pumper Operation Instructions
- Read Engine Manufacturers Owner’s manual for operation. Check the Oil and Gas levels in your engine.
- Refer to the AR Medium or High-Pressure Pumps manual for specific instructions for pump operation. Check all fluid levels.
- Connect the clear suction hose to the filter assembly on the pump. Be sure to insert the safety clip into the coupling.
- Put the open end of the suction hose into a barrel full of water or if you have purchased the optional water tank, connect the suction hose from the tank to the filter assembly. Again, insert the safety clip into the coupling.
- CAUTION: DO NOT CONNECT THE SUCTION HOSE TO A PRESSURE SOURCE OF WATER. Doing so can cause damage to your test pump. If you have purchased the optional water tank, you can connect it to a pressure source of water.
- Refer to Operation Instructions in the AR Manual, included with this manual, for detailed instructions on setting the control unit. Refer to instructions for the 9910-GS40GI Control Unit used on our HTP10-500 pumps and the 9910-VDR50 Control Unit used on our HTP23-700 pump.
- Before you start the engine, raise the pressure release lever. This will take pressure off the pump and make starting the engine easier.
- Start the engine and let it run for about one minute. Turn the engine off and recheck fluid levels on the pump and the engine.
- You are now ready to make a connection to your water main.
Filling the water main prior to hydrostatic pressure testing
- Fill the water main following the recommendations of the American Water Works Association (AWWA). These recommendations can be purchased online at the AWWA website at www.awwa.org. Also, refer to the pipe manufacturer’s recommendations.
- Improper filling of the water main can cause damage to the water main and can be a safety hazard.
- WARNING! It is important to get as much air out of the water main prior to testing as is possible. Air is a compressible gas and can turn your water main into a potential “bomb” causing extensive damage to the water main and injury or death to workers in the area. If you are pressure testing the water main and it is taking a lot of water to bring the pressure up, abort the test immediately and recheck the water main for trapped air.
- Note: Since water is nearly incompressible, it will not take much water pumped from your Old Faithful Pumper to bring water line pressure up to test pressure.
- For example, if you had an 8-inch water main, 1,000 feet long, and all of the air was removed or purged from the water line, it would only take about one cup of water to bring the pressure up to 150 PSI.
- WARNING; IF YOU ARE USING TOO MUCH WATER, ABORT THE TEST IMMEDIATELY AND RECHECK THE WATER MAIN FOR TRAPPED AIR.
Connecting your Old Faithful Pumper to the water main
- Read all warnings displayed on the Old Faithful Pumper before the operation!
- WARNING! Do not run your Old Faithful Pumper in temperatures below 45° F.
- WARNING! Inspect the supplied high pressure hose for nicks, cuts or abrasions. If there are any signs of wear, discard the hose immediately and call Hurco to order replacement parts or hoses.
- Connect the supplied high pressure hose to the pressure outlet on the front of the Old Faithful Pumper. Insert the safety clip.
- Determine where you will be making your connection to the water main. Follow the American Water Works Association (AWWA) recommendations or the recommendations of your project engineer or municipality.
- This connection is critical. Do not leave anything to chance. You must use high quality parts. Be sure they are in new condition and meet or exceed the pressure maximum pressure rating of your pump and have been properly installed. The supplied high pressure hose has a 1/2 inch male iron pipe thread fitting on the end. You will need to build your connection from this fitting. Use a high quality, high pressure, pipe thread sealer on this fitting.
- After you have made this connection to the water main, secure the hose so it will not “whip” in the event the connection you have made fails.
- Recheck all connections and fittings. Be sure all safety clips are in place and the high pressure hose is properly secured to prevent “whipping”.
- A typical setup for hydrostatic testing shown
- WARNING: Do not use your Old Faithful Pumper in temperatures below 45° F. Do not use worn or damaged parts when making a connection to the water main.
- Be sure all air is out of the water main before testing.
Hydrostatic Testing the Water Main
Now that you have properly made all connections to your water main and have ensured that the water main was properly filled to eliminate trapped air, you are ready to start your test. Follow these steps;
- Read all warnings displayed on the Old Faithfull Pumper before the operation!
- WARNING! Do not pressure test in temperatures below 45° F.
- Make sure your water source is full. (Do not connect to a high-pressure water source unless you are using the Hurco optional float-controlled reservoir.)
- Raise the pressure release lever to relieve pressure on the pump when starting the engine.
- Start the engine.
- Be sure the relief or bleed-off valve is in the closed position.
- Lower the pressure release lever into the locked position on the appropriate number setting, (refer to your AR manual).
- Slowly open the high-pressure valve on the front of the Old Faithfull Pumper and allow the pressure to build to the test pressure.
- Once the desired pressure is achieved, slowly close the high-pressure valve. This will isolate the pressure in the water main.
- Raise the pressure release lever and turn off the engine.
Maintenance Instructions
Maintenance Instructions for your Old Faithful Pumper
Your Old Faithful Pumper will give you years of reliable service if you follow these simple maintenance instructions.
-
Always refer to the detailed safety and maintenance instructions in your Hypro manual.
-
After every use, flush the pump with a neutralizing solution for the liquid just pumped. For normal use, a high-quality anti-freeze will do the job. Brands such as Prestone and Zerex contain cleaning and lubrication agents as well as rust inhibitors. Flush the pump for 4 or 5 minutes to thoroughly clean the internal working parts of the pump. A simple procedure would be to put the anti-freeze in a 5-gallon bucket, insert both the suction hose and the pressure hose in the bucket, and allow it to circulate.
WARNING! Remember to secure the high-pressure hose so it does not “Whip”. -
Your Old Faithful pump came with oil in the pump crankcase. It is recommended to change the oil after 40 hours of break-in operation, and every three months or 500 hours, whichever comes first. Use high-grade, non-detergent, SAE 30-weight oil. To drain oil from the pump, remove the drain plug and the sight glass cover and rotate the shaft until the oil stops flowing out. To fill the pump with oil, slowly pour oil into the sight tube while turning the pump shaft. Turning the pump shaft purges all the air out of the crankcase. Always change the oil when replacing diaphragms.
-
For winter storage if a freezing condition will be encountered, flush the Old Faithfull Pumper with a 50/50 mixture of water and anti-freeze.
-
Gear Reduction Crankcase – Use 90W Gear Lube. To properly fill, remove the side level plug and the vent plug. Fill until the gear lube is no higher than the mark on the dipstick. Replace and tighten the side level plug and the top vent plug.
Determining Water Loss for Test Results
There are many methods to determine water loss. Using a water meter would be one method. A simpler method to measure water loss would be as follows;
- Monitor pressure loss for the specified time recommended by the engineer or municipality.
- Note the pressure drop. For example, the test called for a 180 PSI test, and during the test period, the pressure dropped to 140 PSI.
- Now, with your Old Faithfull Pumper still connected to the water main, repeat the instructions for “Hydrostatic Testing the Water Main” on pages 4 and 5 in this manual.
- Pump the pressure in the water main back to the test pressure. In this example, 180 PSI.
- Connect a short piece of garden hose to the relief connection on the Old Faithful Pumper.
- Put the hose into a clean barrel or 5-gallon bucket.
- Slowly open the relief valve and allow water to drain into the barrel until the pressure reading on the pressure gauge drops to the low pressure. In this example that would be 140 PSI.
- Measure water in barrel, this is your water loss.
Parts Replacement, Miscellaneous Repairs and Troubleshooting
To replace the valves or diaphragms or to do any repairs to your Old Faithful
Test Pump, refer to the AR Medium or High-Pressure Diaphragm Pumps manuals.
Refer to the engine manufactures Operations Manuals for specific information
on routine maintenance and trouble shooting.
Parts Breakdown
Old Faithful Parts Breakdown
This parts breakdown is to help you identify any parts that may need to be replaced or repaired. For help repairing your Old Faithful Hydrostatic Test Pumps or to order parts, call our office at 1-800-888-1436.
REF # | PART # | DESCRIPTION | # REQD |
---|---|---|---|
1 | 9910-320410 | tension spring housing | 1 |
2 | 9910-320480 | pin | 1 |
3 | 9910-320460 | lever guide | 1 |
4 | 9910-320470 | pressure relief lever | 1 |
5 | 9910-320490 | locking clip | 1 |
6 | 9910-320450 | pressure adjustment nut | 1 |
7 | 9910-320440 | threaded guide | 1 |
8* | 9910-320420 | tension spring | 1 |
9 | 9910-230120 | tension spring seat | 1 |
10 | 9910-320433 | relief valve poppet retainer | 1 |
11 | 9910-320511 | gasket seal – o-ring | 1 |
12 | 9910-390140 | tension spring guide/seal | 1 |
13 | 9910-110121 | relief valve seat (red) | 1 |
14 | 9910-320420 | tension spring | 1 |
15 | 9910-450110 | spring holder | 1 |
16 | 9910-550350 | o-ring | 1 |
17 | 9910-620220 | relief valve body | 1 |
18 | 9910-130171 | plug | 1 |
19A | 9910-KIT2497 | ball valve L (horizontal) | 1 |
19B | 9910-130491 | ball valve R (vertical) | 1 |
20 | 9910-180370 | bolt | 2 |
REF # | PART # | DESCRIPTION | # REQD |
--- | --- | --- | --- |
21 | 961-5406P-4 | 1/4” plug | 2 |
22 | 961-5406P-6 | 3/8” plug | 1 |
23 | 4200-109 | pressure gauge | 1 |
24 | 961-5503-4-4 | 45-degree elbow | 1 |
25 | 961-5502-8-8 | 90-degree elbow | 2 |
26 | 4200-118 | hose bushing | 1 |
27 | 4200-107 | pressure manifold | 1 |
28 | 4200-124 | recirculation hose | 1 |
29 | 4200-106 | inlet manifold | 1 |
30 | 4200-111-11 | filter body | 1 |
31 | 4200-111-13 | strainer screen | 1 |
32 | 4200-111-12 | filter clear bowl | 1 |
33 | 4200-111-14 | filter gasket | 1 |
34 | 961-5404-16-16 | 1” straight fitting | 1 |
35 | 4200-114 | 1” compressor fitting | 1 |
36 | 4200-115-10 | r-clip | 6 |
37 | 4200-113 | 1/2” coupler | 1 |
KITS AVAILABLE
9910-1923| regulator valve| ref#1-14
9910-KIT1757| control unit repair kit| ref# 10-15
9910-GS40GI| control unit assembly| ref# 1-20
4200-111| line strainer assembly| ref# 30-33
HTP10-500 Pump Assembly Parts
REF # | PART # | DESCRIPTION | # REQD |
---|---|---|---|
1 | 9910-629011 | pump body | 1 |
2 | 9910-620101 | head assembly right | 1 |
3 | 9910-620102 | head assembly left | 1 |
4 | 9910-621430 | bolt 12×55 | 8 |
5 | 9910-620085 | diaphragm desmo pan clear | 2 |
6 | 9910-620120 | piston | 2 |
7 | 9910-620140 | connecting rod | 2 |
8 | 9910-620110 | piston sleeve | 2 |
9 | 9910-580470 | retainer ring | 2 |
10 | 9910-380300 | connecting rod pin | 2 |
11 | 9910-380080 | retainer ring | 4 |
12 | 9910-160230 | piston ring | 2 |
13 | 9910-580360 | retaining bolt | 2 |
14 | 9910-1040180 | retaining washer | 2 |
15 | 9910-550131 | locknut | 2 |
16 | 9910-180150 | nut | 2 |
17 | 9910-620030 | o-ring | 4 |
18 | 9910-1409050 | check valve assembly | 4 |
19 | 2406-0023 | drain plug | 1 |
20 | 9910-111120 | retainer ring | 1 |
21 | 9910-620020 | oil sealing cap | 1 |
22 | 9910-620210 | o-ring | 1 |
23 | 9910-620291 | retaining ring | 1 |
24 | 9910-620190 | ball bearing | 1 |
25 | 9910-850850 | washer | 2 |
26 | 9910-550331 | M6 x 30 bolt | 2 |
27 | 9910-550330 | stud | 2 |
28 | 9910-180101 | o-ring | 1 |
29 | 9910-550030 | oil sight glass | 1 |
30 | 9910-550040 | o-ring | 1 |
31 | 9910-550056 | cap for sight glass | 1 |
32 | 9910-620160 | spacer washer | 1 |
33 | 9910-550060 | roller bearings | 1 |
34 | 9910-620130 | seal | 1 |
35 | 9910-620330 | retainer ring | 1 |
36 | 9910-620170 | crankshaft | 1 |
37 | 9910-620150 | manifold | 1 |
38 | 9910-180101 | o-ring | 1 |
39 | 9910-650660 | damper body OBSOLETE* | 1 |
40 | 9910-650670 | damper diaphragm | 1 |
41 | 9910-650690 | clamp | 1 |
42 | 9910-622070 | accumulator manifold | 1 |
43 | 9910-550190 | accumulator diaphragm | 1 |
44 | 9910-629211 | accumulator’s head – comes with #45 & #46 | 1 |
45 | 9910-650542 | o-ring | 1 |
46 | 9910-180020 | air valve | 1 |
47 | 9910-390060 | o-ring | 4 |
48 | 9910-621780 | bolt | 8 |
49 | 9910-390270 | nut | 2 |
50 | 9910-740290 | o-ring | 1 |
51 | 9910-46730 | damper assembly | 1 |
KITS AVAILABLE
PART #| DESCRIPTION| INCLUDES:
9910-KIT1916| o-ring kit| ref# 17, 22, 28, 30, 45, 47, 50
9910-KIT2110| diaphragm kit| ref# 5, 17, 43 (buna)
9910-KIT1724| diaphragm kit| ref# 5, 17, 43
9910-KIT1917| valve repair kit| ref# 17, 18
39 is obsolete. Replaced by #51, which includes #38-41
HTP10-500 Component Assembly Parts
REF # | PART # | DESCRIPTION | # REQD |
---|---|---|---|
1 | 4200-101 | pump base | 1 |
2 | 4200-102 | pump protection frame | 1 |
3 | 4200-104 | Honda engine | 1 |
4 | 9910-D30-GRGI | pump and gear box | 1 |
5 | 4200-140A | complete control unit | 1 |
6 | 4200-309 | handles | 2 |
7 | 4200-310 | handle grips | 2 |
8 | 4200-303 | support foot | 2 |
9 | 4200-302 | axle | 2 |
10 | 4200-912 | test pump wheels | 2 |
11 | 4200-304 | axle spacer | 2 |
12 | 4200-119 | manifold bracket | 1 |
13 | 4200-206 | frame plug | 4 |
15 | 901-299 | u bolt 1/4 x 1/2 | 1 |
16 | 902-105 | bolt 5/16 x 1-3/4 (110120228) | 4 |
REF # | PART # | DESCRIPTION | # REQD |
--- | --- | --- | --- |
17 | 903-103 | bolt 5/16 x 1-1/4 (110120326) | 4 |
18 | 901-105 | bolt 5/16 x 1-3/4 (110120228) | 2 |
19 | 901-102 | bolt 5/16 x 1 (110120325) | 4 |
20 | 903-021 | washer 1/4×2-/12 (1152025025020) | 2 |
21 | 902-020 | washer 5/16 (1133006) | 4 |
22 | 902-020 | washer 5/16 (1133006) | 4 |
23 | 902-020 | washer 5/16 (1133006) | 4 |
24 | 901-001 | 5/16-18 nylock (1137021) | 4 |
25 | 901-001 | 5/16-18 nylock (1137021) | 4 |
26 | 901-001 | 5/16-18 nylock (1137021) | 4 |
27 | 4200-306 | cotter pin 1/8×1 | 2 |
28 | 9910-651000 | bolt | 4 |
Not Pictured | 4200-125A | outlet hose w/female fitting | 1 |
--- | --- | --- | --- |
Not Pictured | 4200-126A | suction hose w/ fitting | 1 |
HTP10-500 Gear Box Assembly Parts
9910-KIT1640/full gearbox assembly
REF # | PART # | DESCRIPTION | # REQD |
---|---|---|---|
1 | 9910-620561 | o-ring | 1 |
2 | 9910-180030 | bolt | 1 |
3 | 9910-621000 | pump adapter flange | 1 |
4 | 9910-620990 | bearing | 1 |
5 | 9910-651620 | gear | 1 |
6 | 9910-200231 | lock washer | 6 |
7 | 9910-620470 | bolt | 3 |
8 | 9910-620950 | gasket | 1 |
9 | 9910-651000 | bolt | 4 |
10 | 9910-620960 | gearbox body | 1 |
11 | 2406-0023 | drain plug | 2 |
12 | 9910-740290 | o-ring | 2 |
13 | 9910-1140370 | vent plug | 1 |
14 | 9910-621660 | pinion gear | 1 |
15 | 9910-621010 | bolt | 4 |
16 | 9910-320240 | retaining ring | 2 |
17 | 9910-961780 | bearing | 1 |
18 | 9910-320240 | retaining ring | 2 |
19 | 9910-961800 | seal | 1 |
20 | 9910-961790 | retaining ring | 1 |
21 | 9910-881090 | key | 1 |
Limited Warranty
- When used under instructions, HURCO Technologies, Inc. will replace the original purchasers, free of charge, any part or parts of the Old Faithful Test Pumps, excluding the engine and AR Pumps, found to be defective in material or workmanship or both; this is the exclusive remedy. All transportation charges on parts submitted for replacement under this Warranty must be borne by the purchaser. The engine and AR Pump is warranted as outlined by each manufacturer’s separate, limited warranty only. This warranty does not cover damage or loss to the Old Faithfull Hydrostatic pumps due to operating negligence, or due to accident or other casualty.
- THERE IS NO OTHER EXPRESS WARRANTY OR IMPLIED WARRANTY. THIS WARRANTY IS LIMITED TO A PERIOD OF ONE YEAR FROM THE DATE OF PURCHASE AND THE EXTENT PERMITTED BY APPLICABLE LAW, ANY AND ALL IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY EXCLUDED, TO THE EXTENT PERMITTED BY LAW. IN NO EVENT SHALL THE WARRANTOR BE LIABLE FOR DIRECT, INDIRECT, INCIDENTAL, AND CONSEQUENTIAL DAMAGES RESULTING FROM ANY DEFECT IN THE GOODS, TO THE EXTENT SUCH AVOIDANCE IS PERMITTED BY APPLICABLE LAW.
- www.hurcotech.com
- 1-800-888-1436
- www.hurcotech.com
- info@hurcotech.com
- REV: 07/26/2021 Part No. HTP-OM
Documents / Resources
|
HURCO TECHNOLOGIES HHTP10500H Old Faithful Pumper Hydrostatic Test
Pump
[pdf] User Guide
HHTP10500H Old Faithful Pumper Hydrostatic Test Pump, HHTP10500H, Old Faithful
Pumper Hydrostatic Test Pump, Faithful Pumper Hydrostatic Test Pump, Pumper
Hydrostatic Test Pump, Hydrostatic Test Pump, Test Pump
---|---
References
- American Water Works Association
- Water System Maintenance Products | Hurco Technologies, Inc.
- Water System Maintenance Products | Hurco Technologies, Inc.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>