LITHONIA LIGHTING TCC-350L TCC Exit Combo User Guide

September 21, 2024
LITHONIA LIGHTING

LITHONIA LIGHTING TCC-350L TCC Exit Combo

FEATURES & SPECIFICATIONS

INTENDED USE — Ideal for applications that require steel exit or running man sign with emergency lighting.
CONSTRUCTION — 20-gauge steel housing. White powder coat finish. The back-plate contains a universal j box mounting pattern to facilitate ease of installation on a wide variety of j-boxes and the front housing allows access for ease of maintenance.
Faceplate and back cover are interchangeable on housing.
Uniform graphical illumination without shadows or hot spots.
City of Chicago and Standard Exit Models: Letters are 6″ high, with 100 ft viewing distance.

OPTICS — White LED technology provides uniform illumination to meet city of Chicago requirements and Canadian Standards.
Low energy consumption. LED lamp operates in normal (AC input) and emergency modes.
The 350L features two high performance LEDs rated at 1.6 watts each and delivers a total of 371 lumens.
The 750L features two high performance LEDs rated at 3.5 watts each and delivers a total of 775 lumens. (Meets minimum required output for the City of Chicago).

ELECTRICAL — UVOLT (120 thru 347V, 50/60hz). Current-limiting charger maximizes battery life and minimizes energy consumption to provide low operating costs.
Short-circuit protection — current-limiting charger circuitry protects printed circuit board from shorts.
Regulated charge voltage maintains a stable charge voltage over a wide range of line voltages.
Prevents over/undercharging that shortens battery life and reduces capacity. Filtered charger input minimizes charge voltage ripple and extends battery life.
BATTERY: Nickel Metal Hydride battery (9.6V). Optional High-Output (HO option) provides remote capacity and/ or extended run time.

INSTALLATION — Universal (end-, or back-) mount. Top mount by relocating lamp head to the side or pendant mount (conduit not included for pendant mount). Canopy provided. Easily removed mounting knockouts. J-box pattern on back panel.
Side and top conduit knockouts available.
Product is shipped standard with lamp heads on top. Field configurable for side-mount lamp heads. Back Panel included with all configurations.
City of Chicago Models: Glass panel sold separately.
Standard Exit Models: Ships standard with red and green panels for easy field conversion for single or double face. Chevron knockouts.

LISTINGS — UL damp location listed at 32-104°F (0-40°C). Panels with side chevron options and panels with no arrows are fully compliant with UL924 requirements. Models with the full arrow on the bottom of the sign panel are not consistent with UL924 panel requirements, however, these panels are required per the City of Chicago Code. NFPA 101 (current Life Safety code), NFPA 70 (NEC), California Energy Commission Title 20 section 1605.3 (W)(4), FCC Title 47, Part 15, Subpart B, Class B and OSHA. Listed and labeled to comply with Canadian Standards C22.2 No. 141-10. Meets City of Chicago Code.

WARRANTY — 5-year limited warranty (pro-rata battery). This is the only warranty provided and no other statements in this specification sheet create any warranty of any kind. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms and conditions
Note: Actual performance may differ as a result of end-user environment and application.
All values are design or typical values, measured under laboratory conditions at 25 °C.
Specifications subject to change without notice.
† Exit Signs Certified in the CA Title 20 Appliance Efficiency Database.

INDURA® COMMERCIAL EXIT/UNIT COMBO

  • Stair Exit Sign

  • Universal Red Green Exit (RG)

Specifications

Length: 12 (30.48)
Width: 2.36 (5.99)
Height fixture: 8.86 (22.50)
Height fixture/head : 13.52 (34.34)
Weight: (Chicago complete fixture) 6.16 (2.79 kgs)

  • Weight will vary based on configuration
    All dimensions are inches (centimeters) unless otherwise specified.

CITY OF CHICAGO EXIT OR STAIR MODELS

Catalog Number| Description| Housing Color| Input Voltage| Nominal Lumens| Remote Capacity
---|---|---|---|---|---
TCC 750L HSG| Steel Emergency Light, EXIT or STAIR Combo, city of Chicago, Glass panel ordered separate| White| 120-347V, 50-60Hz| 750L| –
TCC 750L HO HSG| 6.6W

DIRECTIONAL INDICATOR ORDERING INFORMATION

Catalog Number Description
CHP ENA Exit No Arrow
CHP ERA Exit Right Arrow
CHP ELFA Exit Left Arrow
CHP EDA Exit Double Arrow
CHP SNA Stair No Arrow
CHP SRA Stair Right Arrow
CHP SLFA Stair Left Arrow
CHP SDA Stair Double Arrow

DIRECTIONAL INDICATORS (Exit)

CHP ENA ****
CHP ERA

CHP ELFA| **
CHP EDA| **

CHP SNA ****
CHP SRA ****
CHP SLFA
CHP SDA ****

STANDARD EXIT MODELS

ORDERING INFORMATION

Example: TCC RG 350L

Catalog Number| Description| Housing Color| Input Voltage| Nominal Lumens| Remote Capacity
---|---|---|---|---|---
TCC RG 350L| Steel Exit Combo, Red/Green Configurable, 3 face| White| 120-347V, 50-60Hz| 350L| 2.4W
TCC RG 750L| 750L| —-
TCC RG 750L HO| 6.6W

SPACING GUIDELINES

TCC 750L Spacing Guidelines

Mounting Height| Illumination Level 1| Single Luminaire| Multiple Luminaire| Application Notes
3′ Path of Egress| 6′ Path of Egress| 3′ Path of Egress| 6′ Path of Egress
7.5′| 1FC Avg| 50′| 48′| 71′| 67′| 100′ Corridor, 8′ wide, 12′ high with 80/50/20 reflectances
10′| 1FC Avg| 54′| 44′| 70′| 64′
7.5′| 1FC Avg| 54′| 50′| 65′| 62′| Retail Open Area: 200′ X 15′ X 30′ with 80/50/20 reflectances
10′| 1FC Avg| 56′| 50′| 68′| 61′
12′| 1FC Avg| 50′| 48′| 54′| 54′
16′| 1FC Avg| 44′| 42′| 54′| 50′
20′| 1FC Avg| 37′| 36′| 44′| 44′
24′| 1FC Avg| 26′| 26′| 36′| 33′
TCC 350L Spacing Guidelines

Mounting Height| Illumination Level 1| Single Luminaire| Multiple Luminaire| Application Notes
3′ Path of Egress| 6′ Path of Egress| 3′ Path of Egress| 6′ Path of Egress
7.5′| 1FC Avg| 30′| 28′| 39′| 38′| 100′ Corridor, 8′ wide, 12′ high with 80/50/20 reflectances
10′| 1FC Avg| 28′| 26′| 38′| 34′

  1. Also meets the additional illumination requirements of NFPA 101: average 1FC minimum and max/min ratio of 40:1.

Remote Compatibility

Fixture| Remote Capacity| ELMRW / ELMRE LP220L Single| ELMRW / ELMRE LP220L Twin| ELMRW / ELMRE SP640L Single| ELMRW / ELMRE SP640L Twin| ERE SQ Single| ERE SQ Twin
TCC 350L| 2.4W| 2| 1| NA| NA| 2| 1
TCC 750L HO| 6.6W| 4| 2| 2| 1| 6| 3

  • Refer to remote spec sheets for additional information: ELMRW, ERE

EXTENDED RUN-TIME FOR HIGH-OUTPUT
TCC 350L (no remotes): up to 3 hours
TCC 750L HO (no remotes): up to 4.5 hours

SPACING GUIDELINES

*Note: To see complete photometric report or download the .ies file for this product, visit Lithonia Lighting TCC home page.

  • Example of multiple TCC 750L luminaires illuminating a 3′ path of egress.

  • Example of single TCC 750L illuminating a 3′ path of egress.

  • Corridor application image.

SPECIFICATIONS

ELECTRICAL

Primary Circuit
| Volts| Input amps| Watts
TCC 350L| 120V| 0.08| 5
347V| 0.08| 5
TCC 750L| 120V| 0.08| 5
347V| 0.08| 5
TCC 750L HO| 120V| 0.08| 5
347V| 0.08| 5
BATTERY

Battery (Nickel Metal Hydride, 9.6V)
Typical Shelf life 1| Typical life 1| Maintenance 2| Temperature Range 3,4
3 year| 6-8 years| none| 32°-104°F (0-40°C)

Notes

  1. At 77°F (25°C) ambient temperature, charge/discharge cycles and prolonged full discharge may reduce useful life.
  2. All life safety equipment, including emergency lighting for path of egress must be tested in accordance with all National Fire Protection Association (NFPA) and local codes. Failure to perform the required testing could jeopardize the safety of occupants and will void all warranties.
  3. Temperature range where unit will provide capacity for 90 minutes. Higher and lower temperatures affect life and capacity.
  4. Battery life is negatively impacted by many variables including temperature, charging rates, number of cycles and deep discharges due to long periods of time without AC power.

CUSTOMER SUPPORT

EMERGENCY One Lithonia Way Conyers, GA 30012
Phone: 800-705-SERV (7378)
techsupport-lighting@acuitybrands.com
www.lithonia.com
© 2023-2024 Acuity Brands Lighting, Inc.
All rights reserved. Rev. 09/16/24

References