TRLZ6V2.1 Wi-SUN Mesh Network Interface Card
“`html
Product Information
Specifications
- Product Name: TRLZ6V2.1 Wi-SUN Mesh Network Interface Card
- Manufacturer: Wasion
- Communication Module: TRLZ6V2.1S1
- Frequency: 900MHz
- Compliance: Wi-SUN Alliance standards
Product Usage Instructions
1. Power Requirements
The power requirements for the TRLZ6V2.1 Wi-SUN Mesh NIC are as
follows:
Parameter | Rating | Typical | Maximum |
---|---|---|---|
Receive Mode | 60mA to 70mA | – | – |
Transmit 900MHz | 800mA to 1000mA | – | – |
Last Gasp Alarm | 15mA to 20mA | – | – |
2. Precautions
-
Do not power on unconnected antenna NIC and avoid replacing or
removing the antenna with the power on. -
Ensure all connections are secure before powering on the
device. -
Avoid installing directly in open or wet locations to prevent
damage.
3. FCC Regulatory Compliance Statement
The device complies with Part 15 of the FCC Rules. It must not
cause harmful interference and must accept any received
interference.
Information on Test Modes and Additional Testing
Requirements
Frequently Asked Questions (FAQ)
Q: Can the TRLZ6V2.1 Wi-SUN Mesh NIC be used outdoors?
A: It is recommended to avoid installing the device directly in
open or wet locations to prevent damage.
Q: What are the power requirements for transmit mode?
A: The device requires 800mA to 1000mA in transmit mode at
900MHz.
“`
TRLZ6V2.1 Wi-SUN Mesh Network Interface Card User Manual
http: //www.wasion.com
1 Overview
This document describes TRLZ6V2.1 Wi-SUN RF Mesh NIC (Network Interface Card),
which is based on discrete chip platform as configured for energy meters and
other devices to be used in AMI Solution. TRLZ6V2.1 and power board form the
communication module TRLZ6V2.1S1 which meets the industry-agreed standards for
conformance and interoperability for Wi-SUN Alliance.
2 Power Requirements
The TRLZ6V2.1 RF NIC must be supplied by 5.0±0.5V, > 6W power supply. The necessary power
supply performance is described in Table 4.1 and 4.2.
Table 4.1 Power Supply
Parameter Rating
Un-regulated Voltage
5.0±0.5V
Ripple
±25mV
Transient Response
±200mV
Table 4.2 Operating State Current
Mode
Typical
Maximum
Receive Mode
60mA
70mA
Transmit 900MHz
800mA
1000mA
Last Gasp Alarm
15mA
20mA
3 Precaution
1. It is prohibited to power on unconnected antenna NIC, also replace or
remove the antenna with power on 2. Make sure all connections are good before
power on 3. Do not install directly in open (risk of rain) or wet locations
Add: Avenida Mina de Guadalupe 930, Puerto Interior, Zona Santa Fe IV, C.P. 36275, Silao, Guanajuato. http: //www.wasion.com
4 FCC regulatory compliance statement
§15.19 Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
§15.21 Information to user
Warning: changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
List of applicable FCC rules:
47 CFR Part 15, Subpart C 15.247
Summarize the specific operational use conditions
No applicable.The device is a full module approval.
Limited module procedures
This module is not a limited module.
Trace antenna designs
The antenna is not a trace antenna.
RF exposure considerations
This Module complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance of 20cm between the radiator and your body. This
transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
Antennas
If you desire to increase antenna gain and either change antenna type or use
same antenna type certified, a Class II permissive change application is
required to be filed by us, or you (host manufacturer) can take responsibility
through the change in FCC ID (new application) procedure followed by a Class
II permissive change application.
Label and compliance information
Please notice that if the FCC identification number is not visible when the
module is installed inside another device, then the outside of the device into
which the module is installed must also display a label referring to the
enclosed module. This exterior label can use wording such as the following:
“Contains FCC ID:2BEBA0101TRLZ6V21” any similar wording that expresses the
same meaning may be used.
§ 15.19 Labelling requirements shall be complied on end user device. Labelling
rules for special device, please refer to §2.925, § 15.19 (a)(5) and relevant
KDB publications. For E-label, please refer to §2.935.
Add: Avenida Mina de Guadalupe 930, Puerto Interior, Zona Santa Fe IV, C.P.
36275, Silao, Guanajuato. http: //www.wasion.com
Information on test modes and additional testing requirements
The OEM integrator is responsible for ensuring that the end-user has no manual
instruction to remove or install module. The module is limited to installation
in mobile application, a separate approval is required for all other operating
configurations, including portable configurations with respect to §2.1093 and
difference antenna configurations.
Test software access to different test modes: cent nv rftest 1 Testing item,
Frequencies, Transmit Power, Modulation Type can be selected on the test
script instructions.
FCC other Parts, Part 15B Compliance Requirements for Host product
manufacturer
This modular transmitter is only FCC authorized for the specific rule parts
listed on our grant, host product manufacturer is responsible for compliance
to any other FCC rules that apply to the host not covered by the modular
transmitter grant of certification. Host manufacturer in any case shall ensure
host product which is installed and operating with the module is in compliant
with Part 15B requirements. Please note that For a Class B or Class A digital
device or peripheral, the instructions furnished the user manual of the
enduser product shall include statement set out in §15.105 Information to the
user or such similar statement and place it in a prominent location in the
text of host product manual. Original texts as following: For Class B Note:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures: –Reorient or relocate the receiving antenna.
–Increase the separation between the equipment and receiver. –Connect the
equipment into an outlet on a circuit different from that to which the
receiver is connected. –Consult the dealer or an experienced radio/TV
technician for help. For Class A Note: This equipment has been tested and
found to comply with the limits for a Class A digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the
interference at his own expense.
Add: Avenida Mina de Guadalupe 930, Puerto Interior, Zona Santa Fe IV, C.P.
36275, Silao, Guanajuato. http: //www.wasion.com
Add: Avenida Mina de Guadalupe 930, Puerto Interior, Zona Santa Fe IV, C.P. 36275, Silao, Guanajuato. http: //www.wasion.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>