WASION TRLZ6V3.2 Wi-SUN Mesh Network Interface Card User Manual

July 25, 2024
WASION

WASION TRLZ6V3.2 Wi-SUN Mesh Network Interface Card

SION-TRLZ6V3-2-Wi-SUN-Mesh-Network-Interface-Card-
PRODUCT

Specifications

  • Product Name: TRLZ6V3.2 Wi-SUN Mesh Network Interface Card
  • Manufacturer: Wasion
  • Model: TRLZ6V3.2
  • Interface: Wi-SUN RF Mesh NIC (Network Interface Card)
  • Platform: Discrete chip platform
  • Application: Energy meters and devices for AMI Solution

Product Usage Instructions

The power requirements for the TRLZ6V3.2 are as follows:

  • Do not power on an unconnected antenna NIC.
  • Ensure all connections are secure before powering on.
  • Avoid installing in open or wet locations to prevent damage.
  • The device complies with Part 15 of the FCC Rules. Users must adhere to FCC regulations to avoid interference and maintain safe operation.
  • Ensure a minimum distance of 20cm between the device and the body for safe operation. Do not co-locate this transmitter with other antennas.

FAQ

  • Q: What happens if the antenna is powered on unconnected?
  • A: It is prohibited to power on an unconnected antenna NIC to prevent any potential damage.
  • Q: How should I handle FCC compliance for this device?
  • A: Follow FCC rules and regulations, ensuring proper installation and operation to maintain compliance.
  • Q: Can I change the antenna type or increase antenna gain?
  • A: Any changes to the antenna type or gain require a Class II permissive change application to be filed.

Overview

  • This document describes TRLZ6V3.2 Wi-SUN RF Mesh NIC (Network Interface Card), which is based on a discrete chip platform as configured for energy meters and other devices to be used in AMI Solution.
  • TRLZ6V3.2 and power board form the communication module TRLZ6V3.2S1 which meets the industry-agreed standards for conformance and interoperability for Wi-SUN Alliance.

Power Requirements
The TRLZ6V3.2 RF NIC must be supplied by 5.0±0.5V, > 6W power supply. The necessary power supply performance is described in Tables 4.1 and 4.2.

Table 4.1 – Power Supply

Parameter Rating

Un-regulated Voltage| 5.0±0.5V
Ripple| ±25mV
Transient Response| ±200mV

Table 4.2 – Operating State Current

Mode Typical Maximum
Receive Mode 60mA 70mA
Transmit 900MHz 800mA 1000mA
Last Gasp Alarm 15mA 20mA

Precaution

  1. It is prohibited to power on an unconnected antenna NIC, also replace or remove the antenna with power on
  2. Make sure all connections are good before powering on
  3. Do not install directly in the open (risk of rain) or in wet locations

FCC STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Information to user
Warning: changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

List of applicable FCC rules

  • Add: Avenida Mina de Guadalupe 930, Puerto Interior, Zona Santa Fe IV, C.P. 36275, Silao, Guanajuato. http://www.wasion.com.

Summarize the specific operational use conditions

  • No applicable. The device is a full module approval.

Limited module procedures

  • This module is not limited.

Trace antenna designs

  • The antenna is not a trace antenna.

RF exposure considerations
This Module complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Antennas
If you desire to increase antenna gain and either change antenna type or use the same antenna type certified, a Class II permissive change application is required to be filed by us, or you (host manufacturer) can take responsibility through the change in FCC ID (new application) procedure followed by a Class II permissive change application.

Label and compliance information
Please notice that if the FCC identification number is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. This exterior label can use wording such as the following: “Contains FCC ID: 2BEBA0101TRLZ6V32” Any similar wording that expresses the same meaning may be used.

Labeling requirements shall be complied with on end-user devices.
Labeling rules for special devices, please refer to §2.925, § 15.19 (a)(5), and relevant KDB publications. For E-label, please refer to §2.935.

Information on test modes and additional testing requirements
The OEM integrator is responsible for ensuring that the end-user has no manual instruction to remove or install a module.
The module is limited to installation in mobile applications, a separate approval is required for all other operating configurations, including portable configurations to §2.1093 and different antenna configurations.
Test software access to different test modes: cent nv test 1
Testing items, Frequencies, Transmit Power, and Modulation Type can be selected on the test script instructions.

FCC other Parts, Part 15B Compliance Requirements for Host Product Manufacturer
This modular transmitter is only FCC-authorized for the specific rule parts listed on our grant, host product manufacturer is responsible for compliance to any other FCC rules that apply to the host not covered by the modular transmitter grant of certification.
Host manufacturer in any case shall ensure host product which is installed and operating with the module is in compliant with Part 15B requirements.
Please note that For a Class B or Class A digital device or peripheral, the instructions furnished the user manual of the end user product shall include the statement set out in §15.105 Information to the user or such similar statement and place it in a prominent location in the text of host product manual. Original texts as follows: For Class B

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, according to part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used under the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

For Class A
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, under part 15 of the FCC Rules.

These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used under the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

CONTACT

  • Add: Avenida Mina de Guadalupe 930, Puerto Interior, Zona Santa Fe IV, C.P. 36275, Silao, Guanajuato.
  • http://www.wasion.com

References

Read User Manual Online (PDF format)