“`html
Specifications:
-
Product Name: Smart PXL 100×25 DOT
-
Pixel Type: High Resolution Smart 100x25mm RGB/RGBW pixel
dot -
Operating Voltage: 24V & 48V
-
Connector: Amphenol AT Series Connector
-
Connector Gender: Male and Female
-
Dimensions:
- Male Connector: 58.4 mm x 21 mm
- Female Connector: 43.9 mm x 20.7 mm x 23mm
Product Usage Instructions:
1. Installation Guide:
Check the latest version of the installation guide on the ENTTEC
website for detailed instructions on installing the Smart PXL
100×25 DOT.
2. Cable Core Identification:
Each Smart PXL string or accessory has 3 cores with different
functions and colors. Refer to the cable core identification chart
for proper connection.
3. Electrical Information:
The device operates on DC power and does not require an earth
connection. Ensure to follow all directions and warnings provided
in the installation guide for safe operation.
4. System Planning and Specification:
Prior to installing the system, familiarize yourself with all
key information in the guide and other relevant documentation.
Determine the pixel pitch and quantity of Smart PXL Dots needed
based on your system design.
5. Safety Guidelines:
Respect all directions and warnings in the installation guide to
ensure safe installation and operation of the Smart PXL Dot system.
Contact ENTTEC if you have any questions or uncertainties regarding
the installation process.
FAQ:
Q: Is it necessary to use cable ferrules when connecting
non-tinned cable?
A: ENTTEC recommends using cable ferrules when connecting
non-tinned cable to ensure proper connection and safety.
Q: What is the purpose of the Smart PXL Termination End
Cap?
A: The Smart PXL Termination End Cap is used to protect the
final female Amphenol AT series connector from short circuiting and
corrosion in wet conditions.
“`
Smart PXL 100×25 DOT
Visit the ENTTEC website for the latest version
SMART PXL 100×25 Dot – Installation Guide
High Resolution Smart 100x25mm RGB/RGBW pixel dot (24V & 48V)
Contents
Physical Dimensions
………………………………………………………………………………………………………………………………………………………………………………. 2 Key
Electrical Safety
……………………………………………………………………………………………………………………………………………………………………………….. 4
Protection from Injury During Installation
………………………………………………………………………………………………………………………………………. 4 System Planning and
Specification …………………………………………………………………………………………………………………………………………………… 5 Key
Safety & Functional Limits
……………………………………………………………………………………………………………………………………………………………. 5 Voltage Drop
……………………………………………………………………………………………………………………………………………………………………………………………… 5
Maximum Smart PXL-100×25 Dot Chain Length
…………………………………………………………………………………………………………………………. 5 Connection to a DC PSU
…………………………………………………………………………………………………………………………………………………………………… 6 Data Cable
Length & Direction ……………………………………………………………………………………………………………………………………………………….
6 Control
Channels………………………………………………………………………………………………………………………………………………………………………………… 6
Controlling Smart PXL Dots with ENTTEC OCTO’s
…………………………………………………………………………………………………………………………….7 OCTO System Application
Diagram ……………………………………………………………………………………………………………………………………………….. 8 Controlling
Smart PXL Dots with ENTTEC’s Pixelator System
……………………………………………………………………………………………………… 9 Pixelator System Application Diagram
………………………………………………………………………………………………………………………………………. 10 Installation
Guidelines ………………………………………………………………………………………………………………………………………………………………………….11
Surface installation of Smart PXL-100×25 Dots & Accessories
……………………………………………………………………………………………..11 Catenary mounting
………………………………………………………………………………………………………………………………………………………………………….. 12 Marking
the surface………………………………………………………………………………………………………………………………………………………………………….
12 Servicing, Inspection & Maintenance
……………………………………………………………………………………………………………………………………………… 13 Cleaning
……………………………………………………………………………………………………………………………………………………………………………………………………. 14
Part Codes & Ordering Information
…………………………………………………………………………………………………………………………………………………. 14 Smart PXL Dots
………………………………………………………………………………………………………………………………………………………………………………….. 14 Smart
PXL Dot
Accessories…………………………………………………………………………………………………………………………………………………………….. 14
1 |
ID: 5920463
INSTALLATION GUIDE- v1.1
Physical Dimensions
Note: Lenses are non-removable
Smart PXL-100×25 Dot
Smart PXL 100×25 DOT
Visit the ENTTEC website for the latest version
Amphenol AT Series Connector
58.4 mm
Male
21 mm
19. 6
43.9 mm
Female
20.7 mm
23mm
All ENTTEC Smart PXL Dot accessories are fitted with the same Amphenol AT
series connectors and industrial grade heat shrink as the Smart PXL Dots to
provide additional durability. Each cable accessory has a bend radius View
each accessory’s datasheet for more information.
Smart PXL 2m Male Cable
Used as a convenient method to connect your Smart PXL Dot’s output to a
connection block or other device.
Smart PXL 2m Female Cable
Used as a convenient method to connect your Smart PXL Dot strings to a
connection block or other device.
Smart PXL Power Injector
2 |
ID: 5920463
INSTALLATION GUIDE- v1.1
Smart PXL 100×25 DOT
Visit the ENTTEC website for the latest version
Used to combat voltage drop and injecting up to 10A of power. The power
injector accessory features reverse polarity and transient voltage protection.
Smart PXL 2m Extension (See ordering info for PN)
Used as a convenient method extend the distance between each Smart PXL Dot
string. Refer to voltage drop section
for maximum extension length.
Smart PXL Termination End Cap
The Smart PXL Termination End Cap should be attached at the end of a chain of
Smart PXL DOTs to protect the final
female Amphenol AT series connector from short circuiting and corrosion in wet
conditions. This can be secured to a
surface using an m5 screw or bolt.
Cable Core Identification Chart
Each Smart PXL string or accessory is comprised of 3 cores, the pinout is as follows:
24V
Cable color
Function
Pin on Amphenol Connector
Black
0V
1
White
Data
2
Red
+24V DC
4
48V
Cable color
Function
Pin on Amphenol Connector
Black
0V
1
White
Data
2
Red
+48V DC
3
ENTTEC recommend the use of cable ferrules when connecting non-tinned cable.
3 |
ID: 5920463
INSTALLATION GUIDE- v1.1
Smart PXL 100×25 DOT
Visit the ENTTEC website for the latest version
Check and respect all directions and warnings given within this installation
guide before specifying, installing and operating a Smart PXL Dot system. If
you are unsure or still have any questions about how to install or operate
this product safely, please contact your ENTTEC supplier or speak with ENTTEC
directly.
Key Electrical Safety This product must be installed in accordance with
applicable national and local electrical and construction codes by a person
familiar with the construction and operation of the product and the hazards
involved. Failure to comply with the following installation instructions may
result in death or serious injury. This device can be damaged by excess
voltage. The installation of an overvoltage protection device on the
electrical system may reduce the risk of damage. Provide a means of locking
out AC mains power to the installation to be shut down and made impossible to
reapply accidentally. The use of an adequate RCBO along the mains power inlet
to your installation is recommended. Before applying power to the
installation, check that all power distribution equipment and cables are in a
perfect condition and rated for the current requirements of all connected
devices and factor in overhead. Isolate the installation from power
immediately if Smart PXL Dots, accessories power cables or connectors is in
any way damaged, defective, shows signs of overheating or are wet (if not an
IP67 component). Do not exceed the maximum numbers of Smart PXL Dots and
accessories that can be connected and the maximum cable lengths specified in
this guide and other product documentation. To reduce the risk of fire or
electrical faults do not exceed the ratings and limitations defined in the
product datasheet or this guide. Do not hot swap Smart Pixel strings or
accessories. Shut down power to the installation during cleaning in addition
to when the system is not in use.
Electrical Information This device operates on DC power and excludes an earth
connection.
Installation Safety Do not bend the Smart PXL Dot cable into a curve of less
than 30mm(1.18in) radius.. Do not over stretch cabling sections of your Smart
PXL Dots. Do not operate the Smart PXL Dots if the ambient temperature exceeds
50°C (122°F). The Smart PXL Dots are convection cooled, ensure sufficient
airflow can reach each dot to allow heat to be dissipated. Do not cover or
enclose Smart PXL Dots without a suitable and proven method of dissipating
heat. To contribute to an optimum operating temperature, where possible keep
this device out of direct sunlight. Do not modify the Smart PXL Dots system in
any way. Follow all steps in the installation guidelines section of this
document.
Protection from Injury During Installation Always use suitable personal
protective equipment when installing ENTTEC products. When installing the
Smart PXL Dots above ground level, ensure that the installation hardware and
supporting structure can hold the weight of all the devices they support. In
an overhead installation or where the Smart PXL Dots system may cause injury
if it falls. Block access below the work area and work from a stable platform
whenever installing, servicing or moving the Smart PXL Dots system. Once
installation is completed, check that all hardware and components are securely
in place and fastened to supporting structures.
4 |
ID: 5920463
INSTALLATION GUIDE- v1.1
Smart PXL 100×25 DOT
Visit the ENTTEC website for the latest version
System Planning and Specification
Before planning or installing your system, ensure you are familiarized with
all key information within this guide and other relevant ENTTEC documentation.
If you are in any doubt about system safety, or you plan to install ENTTEC’s
Smart PXL Dots in a configuration that is not covered within this guide,
contact ENTTEC or your ENTTEC supplier for assistance.
ENTTEC’s Return to Base warranty for this product does not cover damage caused
by inappropriate use or application or modification to the product.
The first step of planning an installation is to determine the pixel pitch and
total quantity of Smart PXL Dots required. Use the product datasheet to
determine the light output and pixel pitch your installation requires before
beginning your system design.
Key Safety & Functional Limits
Given the versatility and flexibility of the Smart PXL Dot system, it is
imperative that the system layout stays within the limits defined within this
document. If two or more different limits apply to a configuration, you must
always follow the lowest.
The system design and installation must respect the key safety and functional
limits defined within this guide.
These limits are: · Power Draw · Voltage Drop · Current throughput limit per
string (10A max) · Control channel availability
Voltage Drop
The longer the cable distance from the power source to each dot the more
voltage is dropped. Significant voltage drop can result in lower brightness
and in more extreme cases colour shift. This is an important consideration for
Smart PXL installations with custom pixel pitch and can inform the quantity of
dots per string between power injections.
If cable length can be reduced across your installation, this is recommended.
If you are concerned about voltage drop and the impact on your installation,
contact ENTTEC team or your reseller.
Maximum Smart PXL-100×25 Dot Chain Length
Maximum chain length is determined by voltage drop, power consumption (10A max
throughput) and control channel availability.
Please contact ENTTEC team or reseller for maximum dot chain length fitting
your requirement.
By using ENTTEC’s Smart PXL Power Injector accessory to inject power from
additional PSU’s, the impact of voltagedrop and power consumption can be
removed, leaving control channel availability as the only limiting factor.
5 |
ID: 5920463
INSTALLATION GUIDE- v1.1
Smart PXL 100×25 DOT
Visit the ENTTEC website for the latest version
Connection to a DC PSU
In a Smart PXL installation, one or more DC external PSUs (Power Supply Units)
are required to provide power to
each chain of Smart PXL Dots if your control method does not contain an
integrated PSU.
Your power supply should be located as close as physically possible to the beginning of the chain of Smart PXL Dots to minimize the effect of voltage drop.
For optimum performance and to reduce the impact of voltage drop, ENTTEC recommend the use of multiple smaller DC power supplies at the beginning of each run of Smart PXL Dots, instead of a low quantity of high-capacity power supplies with longer connection cables.
ENTTEC recommend IP67 rated or higher power supplies where applicable with your installation requirement.
The maximum number of Dots that you can safely connect to a PSU is dependent on the selected PSU’s power rating.
The total power consumption of a single chain of Smart PXL Dots must not exceed the PSU’s maximum power rating OR the 10A current throughput limit of each Smart PXL Dot. To determine the total power consumption of a chain of ENTTEC Smart PXL Dots, add together the power consumption for all individual Dots by referring to datasheet electrical information.
ENTTEC’s offers various control system options to drive Smart PXL Dots each designed for different use case scenarios.
Information for each control system type and appropriate wiring methods can be found within the Control Methods section of this guide. Ensure all cabling and control systems have been housed in accordance with the specifications defined within each products datasheet and in line with local electrical regulation.
Data Cable Length & Direction
Smart PXL Dots are controlled using ENTTEC’s proprietary S-PXL 8/16 protocol.
This protocol sequentially addresses each Smart PXL Dot automatically. This
reduces commissioning time by eliminating the need for individual addressing.
Each Smart PXL Dot contains its own data buffering and data, re-shaping circuit. The maximum permissible distances distance between devices is as follows:
Max. distance between S-PXL 8/16 data source Max. distance between Smart PXL string interconnects
3000mm 3000mm
S-PXL data flow through each dot in one direction only. This direction is indicated by the direction of the arrow printed on surface of the dot (center of PCB). In the event surface of PCB is inaccessible, data direction always flows as illustrated with respect to ENTTEC logo on bottom of housing.
Data Direction
For best practice keep all cable run lengths to a minimum to avoid electrical
noise. Avoid running data cabling close to mains power or devices that emit
electromagnetic
noise (i.e. air conditioning units). If data direction instructions are not
followed, Smart PXL Dots will not operate.
Control Channels
Each RGB Smart PXL Dot consumes the equivalent of 6 DMX channels of data.
Each RGBW Smart PXL Dot consumes the equivalent of 8 DMX channels of data.
The hard upper limit to the number of dots you can run from one data feed can
be calculated by dividing the maximum number of data channels per output of
the ENTTEC pixel controller by the DMX channel footprint of the Smart PXL Dot.
Each Smart PXL Dot uses 6 or 8 output channels from your controller
respectively, whether running in an 8-Bit, 16Bit or grouped configuration all
Smart PXL Dots in a chain will sequentially address one after another.
Channel Order Attribute
16-Bit Smart PXL-100×25 Dot RGB DMX Channel Footprint
1
2
3
4
5
6
Red
Red Fine
Green Green Fine
Blue
Blue Fine
6 |
ID: 5920463
INSTALLATION GUIDE- v1.1
The quantity of Smart PXL Dots addressable per ENTTEC controller is as follows:
Smart PXL 100×25 DOT
Visit the ENTTEC website for the latest version
Channel Order Attribute
16-Bit Smart PXL-100×25 Dot RGBW DMX Channel Footprint
1
2
3
4
5
6
7
8
Red
Red Fine
Green
Green Fine
Blue
Blue Fine
White
White Fine
Always consider all limiting factors before finalizing your system design.
Smart PXL Dot Control Options ENTTEC’s offers various products to control
Smart PXL Dots, each designed for different use case scenarios. Key
specification information and application diagrams for each system can be
found within the following section.
Controlling Smart PXL Dots with ENTTEC OCTO’s
The OCTO is a 4 DIN module wide device capable of converting a combined total
of 8 universes of pixel data from ArtNet, sACN or KiNet (4 universes per
output) with a wide operating voltage between 4-60V DC. It contains an inbuilt
network switch for simple device chaining, allowing up to 100m between each
device. The OCTO’s inbuilt web interface allows configuration alongside basic
standalone effects generation for times your installation doesn’t require
control from a centralised playback device.
ENTTEC Controller
OCTO
SKU 71521
Form Factor
4 module DIN (IP-20)
Dimming Control Resolution
8-Bit/ 16-Bit
Outputs per Device
2
Total DMX Channels Per
Output
2048 (4U)
For more information on the products & accessories featured within this guide visit enttec.com
7 |
ID: 5920463
INSTALLATION GUIDE- v1.1
OCTO System Application Diagram
Smart PXL 100×25 DOT
Visit the ENTTEC website for the latest version
Key OCTO Installation Guidelines:
Ensure all safety guidelines within this installation guide and other product
documentation are factored into the design.
Locate the OCTO and PSU as close as possible to the first Smart PXL Dot in the
chain to reduce the impact of voltage drop.
To reduce the likelihood of voltage being induced on the control signal lines,
where possible, run control cabling away from mains electricity or devices
that produce high EMF, (i.e. air conditioning units).
ENTTEC recommends the use of cable ferrules for all stranded cables connected
to the OCTO’s screw terminals to ensure a reliable connection.
ArtNet / sACN / DMX Lighting Players & Controllers
S-Play (SKU: 70092)
PC running ENTTEC ELM Software (SKU: 70581)
Up to 100m Network Link
Network Switch DC PSU
Up to 100m Network Link
OCTO (SKU: 71521)
DC PSU
Up to 100m Network Link
Network Link to Additional Devices
OCTO (SKU: 71521)
DDC CPSPUSU & Protection
Female Cable (SKU 73018) 3m max. cable length between the controller and first
Smart PXL Dot
Female Cable (SKU 73018) DC PSU & DC PSU Protection
DC PSU & DC PSU Protection
Female Cable (SKU 73018) 3m max. cable length between the controller and first
Smart PXL Dot
Female Cable (SKU 73018) DDC CPSUPSU & Protection
Termination Plug (SKU 73015)
Termination Plug (SKU 73015)
Termination Plug (SKU 73015)
Termination Plug (SKU 73015)
Note: If the power or data source to your controller drops out whilst the Smart PXL Dots remain powered, the last state will be held until either the data feed resumes or power to the Smart PXL Dots is disconnected and re- connected.
8 |
ID: 5920463
INSTALLATION GUIDE- v1.1
Smart PXL 100×25 DOT
Visit the ENTTEC website for the latest version
Controlling Smart PXL Dots with ENTTEC’s Pixelator System
ENTTEC’s Pixelator system has been designed with reliability and flexibility
at its heart. The system comprises of two key elements. The Pixelator device
used to perform protocol conversion, and PLink injectors used locally to
convert the data from the Pixelator close to the beginning of each chain of
dots.
Pixelator Devices
Each Pixelator device is configurable via web interface over a local network
and converts DMX over ethernet (Art-Net, sACN or ESP) to ENTTEC’s proprietary
PLink protocol designed to send control data over long distances. Each Plink
output can send 2 universes of data up to 300m over CAT6 cable to ENTTEC’s
PLink injector modules.
ENTTEC Controller
Pixelator
Pixelator Mini DIN Pixelator Mini
PX1-8D
SKU
70060 70066 71066
Form Factor
19″ Rack 1RU (IP-20)
9.5″ Rack 1RU (IP-20)
8 Module DIN (IP-20)
Dimming Control Resolution
8-Bit / 16-Bit
8-Bit / 16-Bit
8-Bit / 16-Bit
Outputs per Device
24 8 8
Total DMX Channels Per
Output
1024 (2U)
1024 (2U)
1024 (2U)
Do not mix controller types within a P-Link System. Different Pixelator models use different processing power appropriate to the hardware design. If your installation requires multiple Pixelators, standardize on one variant to eliminate the risk of content tearing.
PLink Injection Modules
ENTTEC’s compact PLink power injection modules are available in both indoor
and outdoor variants. These surface mount modules convert PLink signal from
the Pixelator to the S-PXL8 / S-PXL16 protocols without configuration. The two
variants compatible with Smart PXL Dots are as follows:
ENTTEC Injection Module
SKU
IP Rating
Data Outputs per Device
Plink Injector (12-24v)
73544
IP-20
1
IP66 Plink Injector
(custom / made to order item
73924
IP-66
1
contact the ENTTEC sales team)
For more information on the products & accessories featured within this guide visit enttec.com
9 |
ID: 5920463
INSTALLATION GUIDE- v1.1
Pixelator System Application Diagram
Smart PXL 100×25 DOT
Visit the ENTTEC website for the latest version
Key Pixelator System Installation Guidelines:
Ensure all safety guidelines within this guide and other product documentation
are factored into the design.
Locate the PLink and PSU as close as possible to the first Smart PXL Dot in
the chain to reduce the impact of voltage drop.
To reduce the likelihood of voltage being induced on the control signal lines,
where possible, run control cabling away from mains electricity or devices
that produce high EMF, (i.e. air conditioning units).
ENTTEC recommends the use of cable ferrules for all stranded cables connected
to the PLink’s screw terminals to ensure a reliable connection.
ArtNet / sACN / DMX Lighting Players & Controllers
S-Play (SKU: 70092)
PC running ENTTEC ELM Software (SKU: 70581)
Network Switch
Pixelator/Pixelator Mini/Pixelator Mini PX18D (SKU: 70060/70066/71066)
PLink CAT6
DC PSU & Protection
Plink Injector 12-24V (SKU: 73544)
Female Cable (SKU 73018)
3m max. cable length between the controller and first Smart PXL Dot
GND
DC PSU & Protection
IP Plink Injector (SKU: 73924)
Female Cable (SKU 73018)
Termination Plug (SKU 73015)
Termination Plug (SKU 73015)
Note: If the power or data source to your controller drops out whilst the Smart PXL Dots remain powered, the last state will be held until either the data feed resumes or power to the Smart PXL Dots is disconnected and re- connected.
10 |
ID: 5920463
INSTALLATION GUIDE- v1.1
Smart PXL 100×25 DOT
Visit the ENTTEC website for the latest version
Installation Guidelines
Always work with a plan of the installation that respects all system
limitations as defined within this guide and adheres to the safety information
on the first page.
Ensure data is flowing from your controller through the string of dots
following the data direction.
Do not cover Smart Pixel Dots with insulating material of any kind. When
installing dots or accessories DO NOT exert any tension on the cabling whilst
tightening.
Installation of this product must be performed by qualified personnel. If ever
unsure always consult a professional.
Ensure that no part of the installation is or can be connected to power until
all work is complete.
Do not install Smart PXL Dots if cabling is damaged. Before connecting Smart
PXL Dots to a power supply, verify that the operating voltage and
frequency are compatible and the power supply is appropriately fused in. Do
not crush or clamp Smart PXL Dot or accessory cabling during installation. Do
not leave connections unprotected or disconnected in damp or wet environments.
All
exposed connectors should be fitted with a Termination Plug (SKU 73015) to
give a watertight seal to protect against corrosion. Do not handle Smart PXL
Dot strings in an energized state. Do not bend the Smart PXL Dot cabling to a
radius smaller than 30mm (1.18in). Do not `hot swap’ Smart PXL Dot strings or
their accessories. Do not leave connectors or accessory cabling in a position
where they could cause a short circuit. Isolate the installation from power
immediately if Smart PXL Dots, accessories power cables or connectors is in
any way damaged, defective, shows signs of overheating or are wet (if not an
IP67 component). Do not sign off a system without ensuring all Smart PXL Dot
and accessory cabling is appropriately restrained, secure and not under
tension from the way it has been installed.
Surface installation of Smart PXL-100×25 Dots & Accessories
The Smart PXL-100×25’s body features 2 * 4.3mm Dia holes designed for use with
suitable fasteners to support the weight of the full Smart PXL Dot string.
Cable termination end caps (SKU: 73015) feature a single M5 hole for use with
pan head screws and bolts.
ENTTEC produces Smart PXL Dot cable accessories for increased convenience on
site. All accessories use the same connectors as the Smart PXL Dot’s. Cabling
should be restrained with cable clips suited to the surface you are mounting
your Smart PXL installation to every 0.5m.
Accessories should be used in-line with the system design considerations of
your selected controller and adhere to the system cable length limitations.
Ordering information can be found at the end of this document.
11 |
ID: 5920463
INSTALLATION GUIDE- v1.1
Smart PXL 100×25 DOT
Visit the ENTTEC website for the latest version
Catenary mounting
ENTTEC recommends UV-resistant, outdoor-use rated cable ties for 2 wire
catenary support of the SmartPXL dots via the mounting holes to eliminate any
rotational stress. Do not place cable tie directly to cable leading in/out of
SmartPXL dot. Positioning cable ties over cable close to dot body will prevent
cable from acting as strain relief for the system and may void the warranty.
If the pitch cable is sagging and needs to be restrained for aesthetic
purposes, a cable tie can be used, but should be positioned as far away from
the dot or heatshrink parts as possible. Do not tighten the cable tie tight to
the catenary cable as this will prevent the system from flexing and dampening
strain on the cable. It can also cause the cable to rub against the catenary
wire and wear away the insulation.
Only drill holes or tighten screws into a surface that do not have cabling,
pipework or other services directly behind.
Never energize a Smart PXL Dot system until installation is complete and it is
safe to do so.
Ensure the surface you are attaching Smart PXL Dots and accessories can
support the weight of all items you attach.
When mounting Smart PXL Dots and accessories, ensure the mounting method is
suitably rated to support the weight of the full Smart PXL Dot string.
Never drill a hole or tighten screws into a surface using a Smart PXL Dot or
accessory as a guide. This can result in damage and compromise the strength of
the product.
If installing Smart PXL Dots outdoors, only use corrosion proof galvanized, or
stainless-steel fixings rated for the installation conditions.
Never allow a string of dots to hang from a structure during installation,
this can result in strain to cabling and damage to the Smart PXL Dots.
Marking the surface
Hold a Smart PXL-100×25 Dot or your Cable termination end cap up to the
surface and accurately mark the hole positioning with a pencil, ensuring that
the spacing between each dot and accessory will not exert any strain on the
Smart PXL Dot cable.
Protect the Smart PXL Dot’s from debris or swarf whilst drilling pilot holes.
Note: When installing, DO NOT connect the Smart PXL Dot cabling until the
screw has been fully tightened to protect it from any un-necessary strain.
Screws
If securing Smart PXL Dots or accessories using machine or self-tapping
screws.
12 |
ID: 5920463
INSTALLATION GUIDE- v1.1
Drill a pilot hole or partially wind a self-tapping screw on the pencil mark
as defined in the previous section before positioning the Smart PXL Dot.
Position each Smart PXL Dot in-line with the entry points, then insert and
fully tighten the screws. DO NOT exert any tension on the cabling whilst
tightening.
Smart PXL 100×25 DOT
Visit the ENTTEC website for the latest version
Bolts
If securing Smart Pixel Dots using bolts, ensure a locking nut is used that
cannot become undone due to vibration.
DO NOT exert any tension on the cabling whilst tightening. ENTTEC recommend
the use of washers.
Servicing, Inspection & Maintenance Servicing, inspection & maintenance should
only be carried out by qualified technicians familiar with all safety
information within this document and the Smart PXL Dot system.
Smart PXL Dots and accessories have no user serviceable parts. If your
installation has become damaged, parts should be replaced.
Power down the entire system and ensure a method is in place to stop the
system from becoming energized during Servicing, Inspection & Maintenance.
Key areas to examine during inspection: Ensure all connectors are mated
securely and show no sign of damage. Ensure all connectors show no sign of
corrosion. Ensure all cabling has not obtained physical damage or been
crushed. Ensure all Smart PXL Dots and accessories are secured to the surface
and have been installed in accordance with the guidelines set out within the
installation guide. Check for dust or dirt build up on the Smart PXL System
and schedule cleaning if necessary. Dirt or dust buildup can limit the
ability for the Smart PXL Dot system to dissipate heat and can lead to damage.
If deemed necessary for a Smart PXL Dot string or accessory to be replaced, it
should be removed in a reverse order to installation as defined in this guide.
The replacement string or accessory should be an appropriate size and be
installed in accordance with all steps within the installation guide.
To order replacement parts contact your reseller or ENTTEC directly.
13 |
ID: 5920463
INSTALLATION GUIDE- v1.1
Smart PXL 100×25 DOT
Visit the ENTTEC website for the latest version
Cleaning
Dust and dirt build up can limit the ability for the Smart PXL Dot system to
dissipate heat resulting in damage. It’s important that the Smart PXL Dot
system is cleaned in a schedule fit for the environment it is installed within
to ensure maximum product longevity.
Cleaning schedules will vary greatly depending on the operating environment of
your Smart PXL Dots. Generally, the more extreme the environment, the shorter
the interval between cleanings.
Before cleaning, power down the system and ensure a method is in place to stop
the system from becoming energized until cleaning is complete.
Do not use abrasive, corrosive or solvent-based cleaning products on a Smart
PXL Dot system.
Do not spray Smart PXL Dots or accessories with a high-pressure water jet.
To clean an ENTTEC Smart PXL system, use low-pressure compressed air to remove
dust, dirt and loose particles. If deemed necessary, wipe the Smart PXL Dots
with a damp microfiber cloth.
A selection of environmental factors that may increase demand for frequent
cleaning include: o Use of stage fog, smoke or atmospheric devices. o High
airflow rates (i.e. in close proximity to air conditioning vents). o High
pollution levels or cigarette smoke. o Airborne dust (from building work, the
natural environment or pyrotechnic effects).
If any of these factors are present, inspect all elements of the system soon
after installation to see whether cleaning is necessary, then check again at
frequent intervals. This procedure will allow you to determine a reliable
cleaning schedule for your installation.
Part Codes & Ordering Information
Smart PXL Dots
Product
Smart PXL-100×25 Dot Please contact ENTTEC team to discuss your customization
need.
Smart PXL Dot Accessories
SKU
Refer to DATASHEET
Product
Smart PXL Termination End Cap (pack of 5)
Smart PXL 2m Male Cable
24V 48V
Smart PXL 2m Female Cable
24V 48V
Smart PXL Power Injector
24V 48V
Smart PXL 2m Extension Cable
24V 48V
Please contact the ENTTEC team to discuss the customization options available.
SKU
73015 73017 73021 73018 73022 73019 73023 73020 73024
Due to constant innovation, information within this document is subject to change.
14 |
ID: 5920463
INSTALLATION GUIDE- v1.1
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>