AUFIT ASW-H09B4 Force Residential Air Conditioners Owner’s Manual
- September 18, 2024
- AUFIT
Table of Contents
AUFIT ASW-H09B4 Force Residential Air Conditioners
Specifications :
- Design Load: Force Series
- Design Cooling Load (PDC): Varies by model
- Design Heating Load (PDH): Varies by model
- Cooling/Heating Output: Varies by model
- Annual Consumption at Cooling Mode: Varies by model
- Annual Consumption at Heating Mode: Varies by model
- Seasonal Energy Efficiency Ratio (SEER): Varies by model
- Electrical Specifications:
- Operating Current: Varies by model for Cooling and Heating modes
- Consumption: Varies by model for Cooling and Heating modes
- Power Supply: 220-240V~, 1 phase, 50Hz
- Dehumidification Volume: Varies by model
- Coolant/Quantity: R32 / Varies by model
- Air Supply: Turbo/High/Medium/Low
- Indoor Unit Sound Power: Varies by mode (Turbo/High/Medium/Low)
- Outdoor Unit Sound Power: Varies by model
- Liquid Pipe Diameter/Air Pipe Diameter: 1/4”, 3/8”
- Maximum Installation Height: 10m
- Dimensions:
- Indoor Unit Dimensions: Varies by model
- Indoor Unit Net Weight: Varies by model
- Outdoor Unit Dimensions: Varies by model
- Outdoor Unit Net Weight: Varies by model
Product Usage Instructions
Fault Self-diagnosis and Power Failure Memory Function:
In case of any issues with the air conditioner, the fault self-diagnosis
feature will help identify the problem. Additionally, if there is a power
failure, the unit will automatically resume operation with the same settings
once power is restored.
Maintenance and Cleaning :
The unit is designed for easy maintenance with third-generation materials that
have a special coating against dirt, making it easy to clean. Regular
maintenance will ensure optimal performance and longevity of the air
conditioner.
Air Distribution and Comfort :
The air conditioner features a four-directional air distribution system that
ensures air flows freely in every direction, creating ideal comfort conditions
in the room quickly. This feature enhances the overall cooling or heating
experience.
Installation Flexibility:
The unit comes with two outlets for easy installation, allowing you to
choose the water outlet placement on either the left or right side for more
flexibility in installation based on your room layout.
Healthier Environment:
The air conditioner includes a self-cleaning function that prevents the
growth of bacteria, ensuring a healthier indoor environment for you and your
family.
FAQ :
-
Q: What should I do if the air conditioner is not cooling/heating properly?
A: Check the air filters and ensure they are clean. Additionally, make sure there are no obstructions around the indoor and outdoor units that could affect airflow. If the issue persists, contact a professional technician for further assistance. -
Q: How often should I clean the air conditioner?
A: It is recommended to clean the air filters every 2-4 weeks depending on usage. Regular maintenance of the unit will help maintain its efficiency and performance.
RESIDENTIAL AIR CONDITIONERS
Force Series
Comfort & Simplicity
Discover the Force range offering the most affordable combination of low consumption, high performance and ease of use.
-
Power Failure Memory Function
In case of power failure, the unit will resume operation automatically with the same settings. -
Easy Maintenance
3rd generation materials with special coating against dirt, easy to clean. -
Two Outlets for Easy Installation
The water outlet can be installed either on the left or the right side for more flexibility. -
(4D) Four-directional Air Distribution
The air flows freely in every direction, creating quickly the ideal comfort conditions in the room. -
Self-cleaning Function
Prevents the growth of bacteria, ensuring a healthier environment.
Force Series
Force ** R32 ASW-H09B4/ AUFIT-EU| ASW-H12B4/
AUFIT-EU| ASW-H18B4/ AUFIT-EU| ASW-H24B4/ AUFIT-EU
---|---|---|---
Design load
Design cooling load (PD| 2.65 KW| 3.50 KW| 5.10 KW| 6.70 KW
Design heating load (PDH)| 2.70 KW| 2.70 KW| 3.60 KW| 5.70 KW
Cooling / Heating output
Cooling| Cooling output (kWatt)| 2.7 (0.6-3.8)| 3.5 (0.8-4.1)| 5.1
(1.3-5.3)| 6.7 (1.8-7.4)
Cooling output (Btu/h)| 9212 (2047-12965)| 11942 (2729-13989)| 17401
(4435-18083)| 22860 (6141-25248)
Annual consumption at cooling mode (kWh/annum)| 148| 198| 270| 359
Heating| Heating output (kWatt)| 2.9 (0.8-4.2)| 3.8 (1.0-4.2)| 5.4
(1.3-5.5)| 7.2 (1.8-8.2)
Heating output (Btu/h)| 10236 (2729-14330)| 12965 (3412-14330)| 18424
(4435-18766)| 24566 (6141-27978)
Annual consumption at heating mode during midseason (kWh/annum)| 938| 938|
1220| 1950
Annual consumption at heating mode during warm season (kWh/annum)| 917| 914|
1017| 1859
Seasonal Energy Efficiency Ratio
Cooling| SEER| 6.20| 6.19| 6.60| 6.53
Energy class at cooling mode| A++| A++| A++| A++
Heating (Midseason)| Midseason SCOP| 4.00| 4.03| 4.10| 4.09
Energy class at heating mode during midseason| A+| A+| A+| A+
Heating (Warmer season)| Warmer season SCOP| 5.10| 5.20| 5.30|
5.27
Energy class at heating mode during a warmer season| A+++| A+++| A+++| A+++
Electrical Specifications
Operating current (A)| Cooling| 3.8 (0.7-7.8)| 5.6 (0.7-7.8)|
7.0 (1.2-7.5)| 10.0 (1.0-12.0)
Heating| 4.1 (1.5-8.0)| 4.9 (1.5-8.0)| 6.0 (1.0-6.6)| 9.5 (1.0-11.0)
Consumption (W)| Cooling| 800 (100-1600)| 1180 (100-1600)| 1520
(280-1700)| 2200 (230-2760)
Heating| 850 (300-1600)| 1100 (300-1600)| 1400 (220-1500)| 2200 (230-2530)
Power supply (V/Ph/Hz)| 220-240V~ / 1 / 50Hz| 220-240V~ / 1 / 50Hz| 220-240V~
/ 1 / 50Hz| 220-240V~ / 1 / 50Hz
Outputs
Dehumidification volume (lt/h)| 1.0| 1.0| 1.6| 2.5
Maximum current (A)| 9.5| 9.5| 9.0| 16.0
Maximum power (kW)| 1.9| 1.9| 1.9| 3.4
Coolant / Quantity (gr)| R32 / 560| R32 / 560| R32 / 1030| R32 / 1300
Air supply (Turbo/H/M/L)| 600/550/500/400 m3/h| 600/550/500/400 m3/h|
850/750/670/600 m3/h| 1300/1150/1010/870 m3/h
Indoor unit sound power (Turbo/H/M/L)| 44/40/36/31 dB(A)| 44/40/37/33 dB(A)|
47/44/40/37 57dB(A)| 50/46/41/36 62dB(A)
Outdoor unit sound power| 53 dB(A)| 53dB(A)| 57dB(A)| 63dB(A)
Liquid pipe diameter / Air pipe diameter| 1/4’’, 3/8’’| 1/4’’, 3/8’’| 1/4’’,
1/2’’| 1/4’’, 5/8’’
Maximum installation height (m)| 10| 10| 15| 15
Dimensions
Indoor Unit| Indoor unit dimensions (mm)| 750x285x200| 750x285x200|
900x310x225| 1082x330x233
Indoor unit net weight (kg)| 8.0| 8.5| 11.0| 14.0
Outdoor Unit**| Outdoor unit dimensions (mm)| 705x530x279| 705x530x279|
817x537x280| 900x350x700
Outdoor unit net weight (kg)| 22.5| 22.5| 25.0| 39.0