ANGEL J3363-ROS126H Multi Channel Water Purifier Instruction Manual

September 9, 2024
ANGEL

J3363-ROS126H Multi Channel Water Purifier

“`html

Product Information

Specifications

  • Product Model: J3363-ROS126H

  • Suitable Water Source: Tap Water

  • Suitable Water Temperature: N/A

  • Working Temperature: N/A

  • Water Inlet Pressure: 0.2 MPa~0.4 Mpa

  • Working Pressure: 0.5MPa~0.8MPa

  • Rated Voltage: 220V

  • Rated Frequency: 50Hz

  • Rated Power: 80W

  • Type of Protection Against Electric Shock: Class II

  • Purified Water Flow for Pure Water: 0.55gal/min

  • Rated Total Water Purification Volume for Pure Water:
    2000gal

  • Purified Water Flow for Purified Water: 0.78gal/min

  • Rated Total Water Purification Volume for Purified Water:
    2600gal

  • Purified Water Flow for Adjusted Water: 0.55gal/min

  • Rated Total Water Purification Volume for Adjusted Water:
    2300gal

  • Purified Water Production Rate: 65%

Product Usage Instructions

Electric Control Schematic Diagram

Diagram showing the electrical components and connections of the
water purifier.

Water Purification Process Flowchart

Flowchart illustrating the water purification process of the
device.

Description of Control Program

Detailed information about the control program and operation
button functionality.

Installation Steps

  1. Connect the water inlet to a suitable water source.

  2. Ensure proper water pressure within the specified range.

  3. Connect power adapter interface to a power source.

  4. Follow the electric control schematic diagram for correct
    wiring.

  5. Install all components as per the packing list.

  6. Check all connections and fittings for leaks before
    operation.

Instructions for TDS Adjustments

To adjust Total Dissolved Solids (TDS) levels:

  1. Use the control valve to regulate TDS levels as needed.
  2. Monitor TDS readings periodically and adjust accordingly.
  3. Consult the user manual for specific TDS adjustment
    procedures.

FAQ

Q: How often should the filter be replaced?

A: It is recommended to clean and replace the filter regularly,
typically every 6 months to ensure optimal performance.

Q: Can the water purifier be used with well water?

A: The water purifier is designed for tap water sources. Well
water may require additional filtration or treatment.

“`

J3363-ROS126H Multi-channel Water Purifier
Instruction Guide

Contents

Precautions

01

Product Introduction

02

Specifications

02

Electric Control Schematic Diagram

03

Water Purification Process Flowchart

03

Description of Control Program

04

Installation Steps

04

Instructions for TDS Adjustments

05

Declaration of Hazardous Substances

06

Repair Guide

06

After-sales Service Record

07

Packing List

07

Precautions
Due to the hydrophilic nature of the RO membrane and the moisturizing ingredients, it is suggested that the water faucet be opened every 2 hours after installation to drain the water for 5 minutes and repeat this operation for more than 10 times to fully ensure the taste and activate the performance of the membrane.
Please be sure to follow the precautions below, which are important to avoid danger and injury. Note Please read this manual carefully before using your purifier, and keep the manual properly for future
reference; Please use this product at an ambient temperature of 4°C to 40°C, in a shady indoor location; Please disconnect the power plug if you will not use the purifier for a long time; The purifier should be placed vertically, but not upside down; Please install a reducing valve at the intake for water pressure above 0.4MPa; Please install a booster at the intake for water pressure below 0.1 MPa; After expiration, the filters need to be replaced by Angel’s professional after-sales personnel before the
purifier can be used normally; This device must be installed and commissioned by Angel after-sales service personnel. Before
installation, please verify that the accompanying accessories in the packing box are sufficient and complete; If the machine comes with no pressure tank and it has not been used for 24 hours, please force flush the whole device and prepare fresh water again before use. If the machine comes with a pressure tank and it has not been used for 72 hours, please force flush the whole device and prepare fresh water again before use. Warning The water inlet temperature must not be higher than 38°C or lower than 5°C; otherwise, the reverse osmosis filter will be damaged; To avoid damage to your purifier, do not block the concentrated water outlet when the purifier is in operation; Concentrated water from the outlet is not drinkable but can be used for cleaning; This device uses an external power adapter. If the power adapter is damaged, to ensure safety, you must buy a new one from the manufacturer or its maintenance department for replacement; To ensure safety, please do not disassemble, repair or commission this device by yourself. In case of any abnormality, please contact after-sales service for maintenance; Damaged power cord must be replaced by professionals from the manufacturer, its maintenance department or similar departments to ensure safety.
01

Product Introduction

3 4

9

5

6

1

7

10

8

11

12 2

15 14 13

No.

Name

No.

1

Cabinet

6

2

Folding PP activated carbon rod composite filter assembly

7

3

Water preparing indicator

8

4

Full water indicator

9

5

Stop button

10

Name Flush button Operation button Water shortage
indicator Water inlet
Drain outlet

No.

Name

11 Pure water outlet

12

Power adapter interface

13 Purified water outlet

14 Adjusted water outlet

15

Control valve

Specifications
Product model Suitable water source Suitable water temperature Working temperature Water inlet pressure
Working pressure Rated voltage
Rated frequency Rated power
Type of protection against electric shock Purified water flow for pure water
Rated total water purification volume for pure water
Purified water flow for purified water Rated total water purification volume for purified water
Purified water flow for adjusted water Rated total water purification volume for adjusted water
Purified water production rate Precautions

J3363-ROS126H Tap water 5°C~38°C 4°C~40°C
0.2 MPa~0.4 Mpa 0.5MPa~0.8MPa
220V 50Hz
80W Class II 0.55gal/min
2000gal 0.78gal/min
2600gal 0.55gal/min
2300gal 65%
Clean and replace the filter regularly

02

Electric Control Schematic Diagram

AC220V

Transformer DC24V

Control panel (aka indicator board)

High-pressure switch Low-pressure switch
Flush solenoid valve
Inlet solenoid valve Booster pump

Water Purification Process Flowchart
9 10

5

4

6

16 15

2

37

12

1

8

11

14

13

No.

Name

No.

Name

1

Water inlet

9

2 Folding PP activated carbon rod composite filter assembly 10

3

Purified water outlet

11

One-way valve Control valve One-way valve

4

Inlet solenoid valve

5

Booster pump

6

Spiral-wound RO membrane component

7

Waste water solenoid valve

12

High-pressure switch

13

Pure water outlet

14

One-way valve

15

Activated carbon filter

8

Drain outlet

16

Adjusted water outlet

Note: The above figure is a schematic diagram of the purification system for reference only. The actual device is subject to change.

03

Description of Control Program

I. Button descriptions

1. The Operation button can be used to switch the machine between normal running and

3

standby. Press it to make the machine run

normally, and press it again to make the

machine enter the standby mode; 2. The Flush button can be used to flush the

2

RO membrane in the machine manually. Press

it to flush the RO membrane, and press it again

to stop flushing; 3. The Stop button can be used to stop the

1

machine.

II. Function descriptions 1. The memory function will be disabled after you press and hold the Operation button for 8 seconds, and the buzzer makes two beeps. The function will be enabled after press and hold the button for 8 seconds again, and the buzzer makes one beep. f2o.rT8hese6c-ohondurs -,caonndtitnhueobuus-zozpeerrmataioknesaltawrmo bfuenecptsio. TnhweilflubnectdioisnabwleilldbaefteenrayboleudpareftsesrapnrdeshsoaldndthheoFldlutshhebbuuttttoonn for 8 seconds again, and the buzzer makes one beep. 3. After the machine works continuously for 6 hours, it will stop running and alarm automatically. The operation indicator will stay on in red and make beeps. The machine will resume normal operations only after you press the Operation or Flush button. 4. When the machine is in water shortage state and water suddenly flows in the source water pipe, the machine will resume normal operations after 1 minute. 5. When the machine is in water preparation state and an outage suddenly occurs at the source water pipe, the machine will give the water shortage alarm after 1 minute.

Installation Steps

After purchasing this device, an appointment can be made with our professional personnel for installation and debugging. Before installation, please make sure that sufficient and complete accessories are included in the package.

Figure 1 Figure 2 Figure 3

I. Install the three-way ball valve (see Figure 1)

1.Take out the three-way ball valve from the accessory box in the carton;

2.Close the water inlet valve and remove the connector (faucet or angle valve,

etc.);

3. Connect the water inlet connector and three-way ball valve (note that the

threaded connection should be sealed with padding materials, seal rings, etc.);

4. Close the three-way ball valve switch and reconnect the original water pipe;

5. Connect the PE pipe to the water outlet of the three-way ball valve, and reserve a

certain length of the PE pipe;

II. Connect the water lines and power supply (see Figure 2)

1. At the mounting position of the water purifier specified by the user, drill holes according to the hole positions shown in Figure 3, and then install and fix the

water purifier (see Figure 3);

2. Connect the PE pipe from the three-way ball valve to the source water inlet of

the water purifier, and the water pipe should be connected securely in place to

Drinking

avoid water leakage;

water equipment

3. Connect the concentrated water drainage port of the water purifier to the place designated by the user with a PE pipe;

Note: Do not install any valve on the concentrated water drainage pipe;

4. Connect the pure water outlet, purified water outlet and adjusted water outlet of

the water purifier to the water inlet of the water purification equipment with the

PE pipe, and reserve a certain length of the pipe;

i5n.tCerofancneecotftthheepwoawteerrpsuurpifpielyr,. aFnirdstt,hceonnninescetrtththeeppoowweer rapdlaupgteorf ttohethweaptoerwer

purifier into the socket;

III. Inspection and debugging

1.Turn on the water inlet ball valve and power supply to start the water purifier. It

will start automatic flushing, and the concentrated water will be drained via the

concentrated water pipe. After about 10 seconds, the flushing will be over and

water production will start automatically. At this time, the purified water will pass

through all filters and flow into the drinking water equipment directly, and the

water purifier will stop working;

2. Stop the device for inspection: Stop the water purifier after the drinking water

equipment is full of purified water, and the concentrated water pipe will stop

draining;

192mm

3. Pipeline inspection: During the trial operation, check the parts, components, and

connections for leak and looseness;

4. Cleaning up: Arrange and fix the incoming and outgoing water pipes and

252mm

concentrated water pipes, and clean up the site;

5. Flushing: It is suggested that the drinking water equipment be opened every 2

hours after installation to drain the water for 20 minutes and repeat this operation

for more than 7 times to fully ensure the taste of pure water and activate the

performance of the membrane.

04

Instructions for TDS Adjustments
I. TDS Adjustment 1. Connect the water inlet, drainage, and pure water pipes as required. Do not connect the pure water outlet pipe to the user’s potable water pipeline. Close the pressure tank ball valve and purified water port ball valve. 2. Turn on the water source and check the connections for water leakage. 3. Connect the power adapter of the purifier, it starts to prepare water, and rinse the RO film and the rear carbon filter according to the instructions first. 4. Test the purified water TDS. After the value is stable, start adjusting the TDS adjustment needle valve to make the TDS to 70-90. 5. Instructions for needle valve of TDS adjustment are as follows:

Mini nut

1. Counterclockwise (left): increase the proportion of water purification and the TDS value increases.

2. Clockwise (right): decrease the proportion of water purification and the TDS value decreases.

3.Tighten the mini nut right-hand to lock the TDS.

Purified water control valve

6. After the TDS-adjusted water comes out stably, turn off the inlet water source and the power supply of the purifier. When there is no water coming out of the pure water pipeline, connect it to the user’s potable water pipeline, and open the pressure tank ball valve. 7. Open the inlet water source and power supply again to check whether the purifier is running normally. After the purifier is full of water and stopped, check again whether the TDS of purified water is in the range of 70-90. 8. If the TDS is beyond the range of 70-90, repeat step 5 to fine-tune the pure water TDS until it meets the requirements.

I. Bypass purified water port As the bypass pipeline of the purified water port is a temporary water supply network, make sure the ball valve is closed during normal operation of the purifier. When the purifier fails, to ensure the water demand of the store operation, open the bypass ball valve to meet the temporary water supply demand. The specific connection and operation are as follows: 1. Connect the water pipes:

Quick-plug plastic valve (The valve is closed when
the handle is vertical)

Ball valve closed

Quick-plug tee

Purified water port

Quick-plug plastic valve 2. Connect the ball valve in the accessories Kit to the purified water port on the filter cartridge at the back of the purifier through the PE pipe, and then connect to the water inlet of the pressure tank with a quick-plug tee. After connecting the pipeline, close the ball valve.

05

Repair Guide

Fault

Cause analysis

Troubleshooting

Water Purifier Not preparing
water

Inlet valve is not open Composite filter blockage RO membrane blockage The power supply is not connected Control board failure

Open the water inlet valve Contact after-sales service personnel for repair Contact after-sales service personnel to replace the filter in time Connect the power supply or contact after-sales service personnel for repair Contact after-sales service personnel for maintenance

Water leaks at Damaged connector seal ring Turn off the water source and contact after-sales the connection Damaged filter cartridge seal ring service personnel for repair

Purified water has an unpleasant
taste or smell

Post-activated carbon filter fails The water purifier has not been used for a long time The water purifier was not flushed as required when it was installed

Contact after-sales service personnel to replace the filter in time Drain the water with unpleasant taste or smell and re-prepare water Re-flush as required

Concentrated water pipe does not drain

Inlet valve is not open Filter blockage Flush solenoid valve blockage

Open the water inlet valve Contact after-sales service personnel to replace the filter in time Contact after-sales service personnel for maintenance

Concentrated water Damaged one-way valve

Close the inlet valve and contact after-sales

pipe keeps draining Damaged inlet solenoid valve service personnel for repair

Contact after-sales service personnel to replace the

Severe RO membrane blockage filter in time

Water purifier Fatigue damage of high-pressure Contact after-sales service personnel to replace the

cannot be stopped switch

part in time

Damaged inlet solenoid valve

Contact after-sales service personnel to replace the

part in time

Water purifier The Check Valve Is Installed starts frequently Inversely, Missing Or Damaged

contact after-sales service personnel for repair

Loud noise

Water pressure is lower than 0.1MPa Increase water inlet pressure

Resonance between the main body Use EPE foam to reduce vibration

and its surroundings

Adjust internal pipeline

Internal water pipe interference

Contact after-sales service personnel to replace the

Composite filter blockage

filter in time

06

After-sales Service Record

Service date Cause of service

Service description

Service personnel signature

User signature Remarks

Packing List

Name

Multi-channel Water Purifier

Spiral-wound RO membrane component

Activated carbon filter

Accessory box of filter
cartridge

Filter cartridge Folding PP activated carbon rod composite filters
PE pipe

Seal rings

Membrane shell wrench

Filter cartridge wrench

Parts box

Power adapter

Metal valve

Quick-plug elbow

Instruction Guide

Quick-plug tee Quick-plug plastic valve

07

Unit set pc pc pc pc pc pc piece piece pc pc pc copy pc pc

Quantity 1 1 1 3 3 1 6 1 1 1 1 1 1 1 1

Production batch No.: Inspector:

See the date on the outer carton
Inspector A1

Shenzhen Angel Drinking Water Industrial Group Corporation Address: 401, No.13 Huiye Road, Tangjia Community, Fenghuang street, Guangming District Shenzhen, Guangdong, P.R. China Mailbox: globalservice@angelgroup.com.cn Official site: www.angelwatersolutions.com Version NO.: ###-24.07

HA-J3363-SMS-03

128g

24.07

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals