ANGEL J3363-ROS126H Multi Channel Water Purifier Instruction Manual
- September 9, 2024
- ANGEL
Table of Contents
- J3363-ROS126H Multi Channel Water Purifier
- Product Information
- Specifications
- Electric Control Schematic Diagram
- Water Purification Process Flowchart
- Description of Control Program
- Installation Steps
- Instructions for TDS Adjustments
- Q: How often should the filter be replaced?
- Q: Can the water purifier be used with well water?
J3363-ROS126H Multi Channel Water Purifier
“`html
Product Information
Specifications
-
Product Model: J3363-ROS126H
-
Suitable Water Source: Tap Water
-
Suitable Water Temperature: N/A
-
Working Temperature: N/A
-
Water Inlet Pressure: 0.2 MPa~0.4 Mpa
-
Working Pressure: 0.5MPa~0.8MPa
-
Rated Voltage: 220V
-
Rated Frequency: 50Hz
-
Rated Power: 80W
-
Type of Protection Against Electric Shock: Class II
-
Purified Water Flow for Pure Water: 0.55gal/min
-
Rated Total Water Purification Volume for Pure Water:
2000gal -
Purified Water Flow for Purified Water: 0.78gal/min
-
Rated Total Water Purification Volume for Purified Water:
2600gal -
Purified Water Flow for Adjusted Water: 0.55gal/min
-
Rated Total Water Purification Volume for Adjusted Water:
2300gal -
Purified Water Production Rate: 65%
Product Usage Instructions
Electric Control Schematic Diagram
Diagram showing the electrical components and connections of the
water purifier.
Water Purification Process Flowchart
Flowchart illustrating the water purification process of the
device.
Description of Control Program
Detailed information about the control program and operation
button functionality.
Installation Steps
-
Connect the water inlet to a suitable water source.
-
Ensure proper water pressure within the specified range.
-
Connect power adapter interface to a power source.
-
Follow the electric control schematic diagram for correct
wiring. -
Install all components as per the packing list.
-
Check all connections and fittings for leaks before
operation.
Instructions for TDS Adjustments
To adjust Total Dissolved Solids (TDS) levels:
- Use the control valve to regulate TDS levels as needed.
- Monitor TDS readings periodically and adjust accordingly.
- Consult the user manual for specific TDS adjustment
procedures.
FAQ
Q: How often should the filter be replaced?
A: It is recommended to clean and replace the filter regularly,
typically every 6 months to ensure optimal performance.
Q: Can the water purifier be used with well water?
A: The water purifier is designed for tap water sources. Well
water may require additional filtration or treatment.
“`
J3363-ROS126H Multi-channel Water Purifier
Instruction Guide
Contents
Precautions
01
Product Introduction
02
Specifications
02
Electric Control Schematic Diagram
03
Water Purification Process Flowchart
03
Description of Control Program
04
Installation Steps
04
Instructions for TDS Adjustments
05
Declaration of Hazardous Substances
06
Repair Guide
06
After-sales Service Record
07
Packing List
07
Precautions
Due to the hydrophilic nature of the RO membrane and the moisturizing
ingredients, it is suggested that the water faucet be opened every 2 hours
after installation to drain the water for 5 minutes and repeat this operation
for more than 10 times to fully ensure the taste and activate the performance
of the membrane.
Please be sure to follow the precautions below, which are important to avoid
danger and injury. Note Please read this manual carefully before using your
purifier, and keep the manual properly for future
reference; Please use this product at an ambient temperature of 4°C to 40°C,
in a shady indoor location; Please disconnect the power plug if you will not
use the purifier for a long time; The purifier should be placed vertically,
but not upside down; Please install a reducing valve at the intake for water
pressure above 0.4MPa; Please install a booster at the intake for water
pressure below 0.1 MPa; After expiration, the filters need to be replaced by
Angel’s professional after-sales personnel before the
purifier can be used normally; This device must be installed and commissioned
by Angel after-sales service personnel. Before
installation, please verify that the accompanying accessories in the packing
box are sufficient and complete; If the machine comes with no pressure tank
and it has not been used for 24 hours, please force flush the whole device and
prepare fresh water again before use. If the machine comes with a pressure
tank and it has not been used for 72 hours, please force flush the whole
device and prepare fresh water again before use. Warning The water inlet
temperature must not be higher than 38°C or lower than 5°C; otherwise, the
reverse osmosis filter will be damaged; To avoid damage to your purifier, do
not block the concentrated water outlet when the purifier is in operation;
Concentrated water from the outlet is not drinkable but can be used for
cleaning; This device uses an external power adapter. If the power adapter is
damaged, to ensure safety, you must buy a new one from the manufacturer or its
maintenance department for replacement; To ensure safety, please do not
disassemble, repair or commission this device by yourself. In case of any
abnormality, please contact after-sales service for maintenance; Damaged power
cord must be replaced by professionals from the manufacturer, its maintenance
department or similar departments to ensure safety.
01
Product Introduction
3 4
9
5
6
1
7
10
8
11
12 2
15 14 13
No.
Name
No.
1
Cabinet
6
2
Folding PP activated carbon rod composite filter assembly
7
3
Water preparing indicator
8
4
Full water indicator
9
5
Stop button
10
Name Flush button Operation button Water shortage
indicator Water inlet
Drain outlet
No.
Name
11 Pure water outlet
12
Power adapter interface
13 Purified water outlet
14 Adjusted water outlet
15
Control valve
Specifications
Product model Suitable water source Suitable water temperature Working
temperature Water inlet pressure
Working pressure Rated voltage
Rated frequency Rated power
Type of protection against electric shock Purified water flow for pure water
Rated total water purification volume for pure water
Purified water flow for purified water Rated total water purification volume
for purified water
Purified water flow for adjusted water Rated total water purification volume
for adjusted water
Purified water production rate Precautions
J3363-ROS126H Tap water 5°C~38°C 4°C~40°C
0.2 MPa~0.4 Mpa 0.5MPa~0.8MPa
220V 50Hz
80W Class II 0.55gal/min
2000gal 0.78gal/min
2600gal 0.55gal/min
2300gal 65%
Clean and replace the filter regularly
02
Electric Control Schematic Diagram
AC220V
Transformer DC24V
Control panel (aka indicator board)
High-pressure switch Low-pressure switch
Flush solenoid valve
Inlet solenoid valve Booster pump
Water Purification Process Flowchart
9 10
5
4
6
16 15
2
37
12
1
8
11
14
13
No.
Name
No.
Name
1
Water inlet
9
2 Folding PP activated carbon rod composite filter assembly 10
3
Purified water outlet
11
One-way valve Control valve One-way valve
4
Inlet solenoid valve
5
Booster pump
6
Spiral-wound RO membrane component
7
Waste water solenoid valve
12
High-pressure switch
13
Pure water outlet
14
One-way valve
15
Activated carbon filter
8
Drain outlet
16
Adjusted water outlet
Note: The above figure is a schematic diagram of the purification system for reference only. The actual device is subject to change.
03
Description of Control Program
I. Button descriptions
1. The Operation button can be used to switch the machine between normal running and
3
standby. Press it to make the machine run
normally, and press it again to make the
machine enter the standby mode; 2. The Flush button can be used to flush the
2
RO membrane in the machine manually. Press
it to flush the RO membrane, and press it again
to stop flushing; 3. The Stop button can be used to stop the
1
machine.
II. Function descriptions 1. The memory function will be disabled after you press and hold the Operation button for 8 seconds, and the buzzer makes two beeps. The function will be enabled after press and hold the button for 8 seconds again, and the buzzer makes one beep. f2o.rT8hese6c-ohondurs -,caonndtitnhueobuus-zozpeerrmataioknesaltawrmo bfuenecptsio. TnhweilflubnectdioisnabwleilldbaefteenrayboleudpareftsesrapnrdeshsoaldndthheoFldlutshhebbuuttttoonn for 8 seconds again, and the buzzer makes one beep. 3. After the machine works continuously for 6 hours, it will stop running and alarm automatically. The operation indicator will stay on in red and make beeps. The machine will resume normal operations only after you press the Operation or Flush button. 4. When the machine is in water shortage state and water suddenly flows in the source water pipe, the machine will resume normal operations after 1 minute. 5. When the machine is in water preparation state and an outage suddenly occurs at the source water pipe, the machine will give the water shortage alarm after 1 minute.
Installation Steps
After purchasing this device, an appointment can be made with our professional personnel for installation and debugging. Before installation, please make sure that sufficient and complete accessories are included in the package.
Figure 1 Figure 2 Figure 3
I. Install the three-way ball valve (see Figure 1)
1.Take out the three-way ball valve from the accessory box in the carton;
2.Close the water inlet valve and remove the connector (faucet or angle valve,
etc.);
3. Connect the water inlet connector and three-way ball valve (note that the
threaded connection should be sealed with padding materials, seal rings, etc.);
4. Close the three-way ball valve switch and reconnect the original water pipe;
5. Connect the PE pipe to the water outlet of the three-way ball valve, and reserve a
certain length of the PE pipe;
II. Connect the water lines and power supply (see Figure 2)
1. At the mounting position of the water purifier specified by the user, drill holes according to the hole positions shown in Figure 3, and then install and fix the
water purifier (see Figure 3);
2. Connect the PE pipe from the three-way ball valve to the source water inlet of
the water purifier, and the water pipe should be connected securely in place to
Drinking
avoid water leakage;
water equipment
3. Connect the concentrated water drainage port of the water purifier to the place designated by the user with a PE pipe;
Note: Do not install any valve on the concentrated water drainage pipe;
4. Connect the pure water outlet, purified water outlet and adjusted water outlet of
the water purifier to the water inlet of the water purification equipment with the
PE pipe, and reserve a certain length of the pipe;
i5n.tCerofancneecotftthheepwoawteerrpsuurpifpielyr,. aFnirdstt,hceonnninescetrtththeeppoowweer rapdlaupgteorf ttohethweaptoerwer
purifier into the socket;
III. Inspection and debugging
1.Turn on the water inlet ball valve and power supply to start the water purifier. It
will start automatic flushing, and the concentrated water will be drained via the
concentrated water pipe. After about 10 seconds, the flushing will be over and
water production will start automatically. At this time, the purified water will pass
through all filters and flow into the drinking water equipment directly, and the
water purifier will stop working;
2. Stop the device for inspection: Stop the water purifier after the drinking water
equipment is full of purified water, and the concentrated water pipe will stop
draining;
192mm
3. Pipeline inspection: During the trial operation, check the parts, components, and
connections for leak and looseness;
4. Cleaning up: Arrange and fix the incoming and outgoing water pipes and
252mm
concentrated water pipes, and clean up the site;
5. Flushing: It is suggested that the drinking water equipment be opened every 2
hours after installation to drain the water for 20 minutes and repeat this operation
for more than 7 times to fully ensure the taste of pure water and activate the
performance of the membrane.
04
Instructions for TDS Adjustments
I. TDS Adjustment 1. Connect the water inlet, drainage, and pure water pipes
as required. Do not connect the pure water outlet pipe to the user’s potable
water pipeline. Close the pressure tank ball valve and purified water port
ball valve. 2. Turn on the water source and check the connections for water
leakage. 3. Connect the power adapter of the purifier, it starts to prepare
water, and rinse the RO film and the rear carbon filter according to the
instructions first. 4. Test the purified water TDS. After the value is stable,
start adjusting the TDS adjustment needle valve to make the TDS to 70-90. 5.
Instructions for needle valve of TDS adjustment are as follows:
Mini nut
1. Counterclockwise (left): increase the proportion of water purification and the TDS value increases.
2. Clockwise (right): decrease the proportion of water purification and the TDS value decreases.
3.Tighten the mini nut right-hand to lock the TDS.
Purified water control valve
6. After the TDS-adjusted water comes out stably, turn off the inlet water source and the power supply of the purifier. When there is no water coming out of the pure water pipeline, connect it to the user’s potable water pipeline, and open the pressure tank ball valve. 7. Open the inlet water source and power supply again to check whether the purifier is running normally. After the purifier is full of water and stopped, check again whether the TDS of purified water is in the range of 70-90. 8. If the TDS is beyond the range of 70-90, repeat step 5 to fine-tune the pure water TDS until it meets the requirements.
I. Bypass purified water port As the bypass pipeline of the purified water port is a temporary water supply network, make sure the ball valve is closed during normal operation of the purifier. When the purifier fails, to ensure the water demand of the store operation, open the bypass ball valve to meet the temporary water supply demand. The specific connection and operation are as follows: 1. Connect the water pipes:
Quick-plug plastic valve (The valve is closed when
the handle is vertical)
Ball valve closed
Quick-plug tee
Purified water port
Quick-plug plastic valve 2. Connect the ball valve in the accessories Kit to the purified water port on the filter cartridge at the back of the purifier through the PE pipe, and then connect to the water inlet of the pressure tank with a quick-plug tee. After connecting the pipeline, close the ball valve.
05
Repair Guide
Fault
Cause analysis
Troubleshooting
Water Purifier Not preparing
water
Inlet valve is not open Composite filter blockage RO membrane blockage The power supply is not connected Control board failure
Open the water inlet valve Contact after-sales service personnel for repair Contact after-sales service personnel to replace the filter in time Connect the power supply or contact after-sales service personnel for repair Contact after-sales service personnel for maintenance
Water leaks at Damaged connector seal ring Turn off the water source and contact after-sales the connection Damaged filter cartridge seal ring service personnel for repair
Purified water has an unpleasant
taste or smell
Post-activated carbon filter fails The water purifier has not been used for a long time The water purifier was not flushed as required when it was installed
Contact after-sales service personnel to replace the filter in time Drain the water with unpleasant taste or smell and re-prepare water Re-flush as required
Concentrated water pipe does not drain
Inlet valve is not open Filter blockage Flush solenoid valve blockage
Open the water inlet valve Contact after-sales service personnel to replace the filter in time Contact after-sales service personnel for maintenance
Concentrated water Damaged one-way valve
Close the inlet valve and contact after-sales
pipe keeps draining Damaged inlet solenoid valve service personnel for repair
Contact after-sales service personnel to replace the
Severe RO membrane blockage filter in time
Water purifier Fatigue damage of high-pressure Contact after-sales service personnel to replace the
cannot be stopped switch
part in time
Damaged inlet solenoid valve
Contact after-sales service personnel to replace the
part in time
Water purifier The Check Valve Is Installed starts frequently Inversely, Missing Or Damaged
contact after-sales service personnel for repair
Loud noise
Water pressure is lower than 0.1MPa Increase water inlet pressure
Resonance between the main body Use EPE foam to reduce vibration
and its surroundings
Adjust internal pipeline
Internal water pipe interference
Contact after-sales service personnel to replace the
Composite filter blockage
filter in time
06
After-sales Service Record
Service date Cause of service
Service description
Service personnel signature
User signature Remarks
Packing List
Name
Multi-channel Water Purifier
Spiral-wound RO membrane component
Activated carbon filter
Accessory box of filter
cartridge
Filter cartridge Folding PP activated carbon rod composite filters
PE pipe
Seal rings
Membrane shell wrench
Filter cartridge wrench
Parts box
Power adapter
Metal valve
Quick-plug elbow
Instruction Guide
Quick-plug tee Quick-plug plastic valve
07
Unit set pc pc pc pc pc pc piece piece pc pc pc copy pc pc
Quantity 1 1 1 3 3 1 6 1 1 1 1 1 1 1 1
Production batch No.: Inspector:
See the date on the outer carton
Inspector A1
Shenzhen Angel Drinking Water Industrial Group Corporation Address: 401, No.13 Huiye Road, Tangjia Community, Fenghuang street, Guangming District Shenzhen, Guangdong, P.R. China Mailbox: globalservice@angelgroup.com.cn Official site: www.angelwatersolutions.com Version NO.: ###-24.07
HA-J3363-SMS-03
128g
24.07
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>