BIOWRAP BioWave Wearable Back Pain Neurostim Compression Sleeve User Guide

September 10, 2024
BIOWRAP

BioWave Wearable Back Pain Neurostim Compression Sleeve

“`html

Specifications:

  • Product Name: Knee BioWrap Silver
  • Color: Silver
  • Size Options: S/M, L/XL
  • Circumference Around Kneecap:
    • S/M: 12 – 15.5 inches
    • L/XL: 15.5 – 19 inches

Product Usage Instructions:

Quick Set Up and Use:

  1. The 4 Snap Cables should already be snapped onto each of the 2
    snaps on the outside of the BioWrap.

  2. Plug the blue connectors at the other end of each BioWrap cable
    into your BioWave Leadwire Cable.

  3. Clean your skin with soap and water using a washcloth in the
    locations that the silver fabric will touch your skin.

  4. Squeeze a separate pea size amount of conductive Theracream
    onto your fingertip and rub into your skin thoroughly over the
    entire area that the silver fabric electrodes will touch your skin.
    Use a pea size amount of cream for each silver fabric
    electrode.

  5. Keep knee and leg fairly straight. Put on the BioWrap and
    velcro it closed firmly for strong but comfortable compression over
    the silver fabric locations.

  6. Plug the leadwire cable into the BioWave device.

  7. Turn on the BioWave device by pressing the power button.

  8. Adjust intensity by pressing the PLUS (+) button to maintain a
    strong but comfortable sensation at the treatment locations.

  9. After the 30-minute treatment, disconnect the cables, remove
    the BioWrap, and store it in a cool dry place.

Directions for Use:

  1. Squeeze a pea size amount of BioWrap Conductive Cream onto your
    fingertip and rub into your skin where the silver fabric will
    touch.

  2. Attach both 4 Snap Cables to the snaps on the back side of the
    BioWrap.

  3. Attach your BioWave Leadwire cable to the connectors on the
    back of the BioWrap.

  4. Line up the hole over the center of your kneecap.

  5. Insert top elastic strap through top D-ring and pull it
    tight.

  6. Pull top strap across the front of your knee and secure with
    Velcro.

  7. Insert lower elastic strap through lower D-ring and pull it
    tight.

  8. Pull lower strap across the front of your knee and secure it
    tight.

FAQ:

Q: Can I use the Knee BioWrap without a BioWaveHOME or

BioWavePRO device?

A: No, the Knee BioWrap is ONLY for use with BioWaveHOME &
BioWavePRO devices as it utilizes Advanced Silver Fabric Electrode
Technology.

“`

®
®
Quick Reference Guide

KNEE BIOWRAP

SILVER
Compression Electrode Garment
Utilizes Advanced Silver Fabric Electrode Technology

See video at
https://biowave.com/support-biowraps/

NOTE: ONLY for use with BioWaveHOME & BioWavePRO.

Questions? Call us!
1-877-BIOWAVE · (1-877-246-9283) support@biowave.com

Size

S / M

Circumference Around Kneecap
12″ – 15.5″

L / XL

15.5″ – 19″

This Package Contains

· One Knee BioWrap Compression Electrode Garment ­ for use on LEFT or RIGHT knee. · One 4.2 oz. Bottle of Theracream Conductive Cream

Elastic Strap Provides Compression just above the knee

Inside View
Top

Hole is Centered Over Kneecap

Elastic Strap Provides Compression at and Below Centerline of Knee
Snap Locations for the 4″ Snap Cables

Bottom
Outside View
Top

Built-in Silver Fabric Electrodes treat front, left & right side of knee
Elastic Velcro Straps Closure

D-Rings for the Elastic Straps

Bottom

Channels for the 4″ Snap Cables

Quick Set Up and Use
See video at biowave.com/support/biowrap
1. The 4″ Snap Cables should already be snapped onto each of the 2 snaps on the outside of the BioWrap.
2. Plug the blue connectors at the other end of each BioWrap cable into your BioWave Leadwire Cable.
3. Clean your skin with soap and water using a washcloth in the locations that the silver fabric will touch your skin.
4. Squeeze a separate pea size amount of conductive Theracream onto your fingertip and rub into your skin thoroughly over the entire area that the silver fabric electrodes will touch your skin. Use a pea size amount of cream for each silver fabric electrode.
5. Keep knee and leg fairly straight. See diagrams on opposite side to put on the BioWrap and velcro it closed firmly so there is strong but comfortable compression over the silver fabric locations.
6. Plug the single end of the leadwire cable into the BioWave device.
7. Press the power button to turn on the BioWave device.
8. Start the treatment by pressing the PLUS (+) button to increase intensity so the sensation felt is strong but still comfortable. As your body adapts to the electrical field and the sensation fades, keep pressing the PLUS (+) button to increase the intensity to maintain a strong but comfortable sensation at the treatment locations.
9. When the 30-minute treatment is over, disconnect the BioWave Leadwire cable from the 4″ Snap Cables, remove the BioWrap from your body and store in a cool dry place.

Directions for Use

These instructions are for attaching the Knee BioWrap to the RIGHT or LEFT knee.

Squeeze a pea size amount of BioWrap Conductive Cream onto your finger tip and rub into your skin thoroughly in the two locations that the silver fabric
will touch the skin.

Both 4″ Snap Cables should already be snapped onto the 2 snaps on the
back side of the BioWrap. Attach your BioWave Leadwire cable to the two connectors on the back of the
BioWrap.
Line up hole over center of kneecap.

Insert top elastic strap through top D-ring.
Pull elastic strap so BioWrap is tight.
Make sure hole stays centered over kneecap.

Pull top strap across front of knee so BioWrap is tight.
Secure Velcro strap to close.
Make sure hole stays centered over kneecap.

Insert lower elastic strap through lower D-ring.
Pull elastic strap so BioWrap is tight.
Make sure hole stays centered over kneecap.

Pull lower strap across front of knee so BioWrap is tight.
Secure Velcro strap to close.

Questions?
biowave.com/support/biowrap · support@biowave.com +1-877-BIOWAVE (+1-877-246-9283)

TROUBLESHOOTING
My BioWave shows a connection error but my BioWrap is plugged in
If your BioWave device shows a connection error when you are fully connected to the BioWrap, remove the BioWrap and follow these steps:
If you forgot to apply Conductive Cream: · CLEAN YOUR SKIN. Remove BioWrap and clean your skin with soap and water in the
region that the silver fabric electrodes touch your skin. Shave any excessive hair in the locations that the silver fabric electrodes touch your skin.
· APPLY A PEA-SIZE AMOUNT OF CONDUCTIVE CREAM directly to skin areas that will be against each of the silver fabric electrodes inside the BioWrap. Gently massage Conductive Cream into the skin allowing it to absorb, before putting on the BioWrap.
If you applied too much Conductive Cream (more than a pea-size amount):
· CLEAN YOUR SKIN. Remove BioWrap and use a dry towel to remove all excess Conductive Cream from your skin and any excess cream from the silver fabric in the BioWrap. Next, reattach the BioWrap and begin the treatment.
The treatment doesn’t feel strong enough
· If the intensity is turned up to the maximum setting and the treatment doesn’t feel strong under the electrodes, pause the treatment, remove the BioWrap and apply more conductive cream to the skin in the areas the silver fabric touches the skin.
· Tighter Compression and/or More Conductive Cream = Stronger Treatment Sensation. · Looser Compression and/or Less Conductive Cream = Less Treatment Sensation.
Questions? Call us!
Call technical support: 1-877-BIOWAVE (1-877-246-9283)
biowave.com/support/biowrap support@biowave.com

IMPORTANT
Contraindications When Not to Use BioWrap
· DO NOT use if you have an implanted cardiac pacemaker. · DO NOT place the silver fabric electrodes in the BioWrap over open
wounds, broken skin, rashy skin or sensitive skin areas like sunburned skin.
NOTE: · BioWrap Wearables MAY BE PLACED over or in the proximity of implanted
orthopedic hardware, including total joint replacements, anchors, plates, rods, screws, pins and clips. · Any serious incident that has occurred in relation to the device should be reported to the manufacturer and the competent authority of the Member State in which the user and/or patient is established.
Cleaning
· DISCONNECT and REMOVE the two 4″ SNAP CABLES before hand washing the BioWrap.
· HAND WASH using mild soap and RINSE in cold water. · PAT DRY with a TOWEL, then let AIR DRY. · DO NOT wash in a washing machine. · DO NOT place in a dryer.

Need help?
Contact us at: 1-877-BIOWAVE · (1-877-246-9283)
support@biowave.com

The information, including but not limited to text, graphics,
images and other material contained herein are for
informational purposes only. Learn more at BioWave.com/
terms-of-use

BioWave Corporation 8 Knight St., Suite 201 Norwalk, CT 06851
© 2024 BioWave Corporation Rev 4 – 240618

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals