Lowes 5376085 6 Light Polished Brass Modern Contemporary LED Dry Instruction Manual
- September 7, 2024
- lowes
Table of Contents
- Lowes 5376085 6 Light Polished Brass Modern Contemporary LED Dry
- Product Specifications
- Product Usage Instructions
- IMAGE FOR FINISHED PRODUCT
- TOOLS REQUIRED
- PARTS TYPE & QTY INCLUDED
- ACCESSORIES & QTY ENCLOSED
- Turn off power
- MAKE INSTALLATION
- FAQ
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Lowes 5376085 6 Light Polished Brass Modern Contemporary LED Dry
Product Specifications
- Item Number: 5376085
- Maximum Voltage: 120V
- Maximum Wattage: Type B, Max 40W per bulb
Product Usage Instructions
Mounting Surface Preparation
Before installation, ensure the mounting surface meets the following
criteria:
- Clean, dry, and flat
- Strong enough to support the fixture
- 1/4 larger than the canopy on all sides
- Correct any gaps exceeding 3/16 between the mounting surface and canopy
Installation Safety Tips
- Always hire a licensed electrician for installation.
- Turn off the electricity before starting any work.
- Ensure the ceiling or wall can support the weight of the lamp.
- Avoid contact with acidic or alkaline substances to prevent surface damage.
- When replacing bulbs, wait for the lamp to cool down before\ handling.
Assembly & Installation Instructions
- Check all parts and accessories as per the illustration provided.
- Remove unwanted parts using pliers during pre-installation.
- Turn off the power before starting installation.
- Securely hang the fixture following the provided guidelines.
Item Number : 5376085
WARNING ( To reduce the risk of fire, electric shock, or personal
injury):
- We suggest installation by a licensed electrician.
- Please read the instructions carefully and save it as you may need it at a later time.
- Before you start, NEVER attempt any work without shutting off the electricity until the work is done.
- Go to the main fuse, or circuit breaker, box in your home. Place the main power switch in the “OFF” position. » Place the wall switch in the “OFF” position.
- The mounting surface should be clean, dry, flat, strong enough, and 1/4” larger than the canopy on all sides. Any gaps between the mounting surface and canopy exceeding 3/16” should be corrected as required.
- Make sure that the ceiling or wall can stand the weight of the lamp before installation.
- Make sure the voltage you are using is 120V. The maximum wattage is Type B, with a max of 40W per bulb.
- Keep the lamp away from acidic and alkaline substances in case of damaging the surface of the lamp.
- When replacing bulbs, you should turn off or unplug the lamp and you must wait until it is cool as bulbs get hot quickly.
- The safety instructions appearing in this manual are not meant to cover all possible conditions that may occur. It must be understood that common sense, caution and care must be used with any electrical products.
IMAGE FOR FINISHED PRODUCT
ORDERING PARTS
Keep this sheet for future reference in case you need to order replacement
parts. All parts for this fixture can be ordered from the place of purchase.
Be sure to use exact wording from illustration when ordering parts.
CLEANING
To clean, wipe the fixture with a soft cloth. Do not use abrasive materials
such as scouring pads or powders, steel wool or abrasive paper.
TOOLS REQUIRED
(NOT INCLUDED)
Before starting assembly and installation please prepare the needed tools as below picture
PARTS TYPE & QTY INCLUDED
- (C ) Single bar (1)
- (D ) Green ground screw (1)
- (E ) Canopy (1)
- (F ) Collar ring (1)
- (G ) Collar loop (1)
- (H) Quick link (2)
- (I) Chain (1)
- (J) Loop (1)
- (K) Arms assembly (1)
- (L) Socket ring (6)
- (M) Lampshade (6)
- (N) Socket (6)
- (O) Arm (6)
ACCESSORIES & QTY ENCLOSED
-
(A) Wire connector (3)
-
(B) Mounting screw (2)
-
Step A1 » Adjust arms (N) to the proper position.
-
Step A2 » Screw loop (J) onto the top of arms assembly (K).
-
Step B1 » By measuring, determine the correct number of links needed for proper hanging height. Using the chain pliers, disconnect and discard the unwanted part.
-
Step B2 » Attach quick link (H) to chain (I) and loop (J) on the top of arms assembly (K).
-
Step B3 » Carefully weave the fixture wires through chain (I) in and out of every other link and stop just when you reach the top of chain (I). Gently pull the wires to ensure the wires are not stressed.
Turn off power
- Before you start the installation, NEVER attempt any work without shutting off the electricity until the work is done.
- Go to the main fuse, or circuit breaker, box in your home. Place the main power switch in the “OFF” position. » Place the wall switch in the “OFF” position.
MAKE INSTALLATION
-
Step C1 » Remove collar ring (F) from collar loop (G). Attach single bar (C) to the outlet box with mounting screws (B).
NOTE: the side of single bar (C) marked “GND” must face out. -
Step C2 » Raise canopy (E) over collar loop (G) and screw collar ring (F) to measure a proper position. Unscrew collar ring (F) from collar loop (G) and remove canopy (E). Refer to the following note, you would know the proper position where collar loop (G) should be located.
NOTE: canopy (E) should be snug against the ceiling and collar loop (G) should be screwed enough threads (no less than 6 threads) on the pre-assembled threaded nipple for more secure hanging.
If not, adjust collar loop (G) on single bar assembly (C) by screwing collar loop (G) in or out of single bar (C) until the secure length is achieved. -
Step C3 » Pass chain (I) through collar ring (F) and then through canopy (E).
-
Step C4 » Open quick link (H), attach quick link (H) to collar loop (G). Close quick link (H). Pass the fixture wires through collar loop (G) to the top of the pre-assembled threaded nipple and gently pull to ensure the wires are not stressed.
-
Step C5 » If needed, shorten the length of fixture wires. At this point, the remaining wire length measured above single bar (C) is at least 6″.
-
Step C6 » Make wire connections
Connect wires as shown in the charts below. PLEASE NOTE THAT GROUND WIRE IS BARE COPPER WIRE, NEVER CONNECT OTHER WIRES TO GROUND WIRES.
Connect ground wires according to the chart below
Connect wires according to the chart below Twist wires together with plastic wire connectors until tightly joined, and wrap each connector with approved electrical tape. Be sure that no wire strands are exposed and then carefully tuck all wires into the outlet box.
GREEN GROUND SCREW -
Step C7 » Raise canopy (E) to the ceiling and secure canopy (E) in place by tightening collar ring (F) onto collar loop (G).
Step C8 »-
Attach lampshades (M) on sockets (N), and then screw socket rings (L) onto sockets (N).
The wider side of socket rings (L) faces sockets (N) as shown in the illustration. -
Install bulbs (not included) (Please do not exceed the maximum wattage recommended on the socket.)
-
Check that everything is installed properly, then you can turn on the light. We hope you enjoy your new lighting!
FAQ
- Q: Can I use bulbs with wattage higher than 40W?
- A: No, the maximum recommended wattage per bulb is 40W to ensure safe operation.
- Q: How should I clean the fixture?
- A: Use a soft cloth for cleaning. Avoid abrasive materials like scouring pads or powders.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>